1 February 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
STSodai Tanaka
Sodai Tanaka
TNTeiji Nishio
Teiji Nishio
MTMasato Tsuneda
Masato Tsuneda
KMKeiichiro Matsushita
Keiichiro Matsushita
SKShigeto Kabuki
Shigeto Kabuki
MUMitsuru Uesaka
Mitsuru Uesaka
Range uncertainty is among the most formidable challenges associated with the treatment planning of proton therapy. Proton imaging, which includes proton radiography and proton computed tomography (pCT), is a useful verification tool. We have developed a pCT detection system that uses a thick bismuth germanium oxide (BGO) scintillator and a CCD camera. The current method is based on a previous detection system that used a plastic scintillator, and implements improved image processing techniques. In the new system, the scintillation light intensity is integrated along the proton beam path by the BGO scintillator, and acquired as a two-dimensional distribution with the CCD camera. The range of a penetrating proton is derived from the integrated light intensity using a light-to-range conversion table, and a pCT image can be reconstructed. The proton range in the BGO scintillator is shorter than in the plastic scintillator, so errors due to extended proton ranges can be reduced. To demonstrate the feasibility of the pCT system, an experiment was performed using a 70 MeV proton beam created by the AVF930 cyclotron at the National Institute of Radiological Sciences. The accuracy of the light-to-range conversion table, which is susceptible to errors due to its spatial dependence, was investigated, and the errors in the acquired pixel values were less than 0.5 mm. Images of various materials were acquired, and the pixel-value errors were within 3.1%, which represents an improvement over previous results. We also obtained a pCT image of an edible chicken piece, the first of its kind for a biological material, and internal structures approximately one millimeter in size were clearly observed. This pCT imaging system is fast and simple, and based on these findings, we anticipate that we can acquire 200 MeV pCT images using the BGO scintillator system.

7 December 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
STSodai Tanaka
Sodai Tanaka
YNYoshiyuki Noto
Yoshiyuki Noto
SUSatoru Utsunomiya
Satoru Utsunomiya
TYTakaaki Yoshimura
Takaaki Yoshimura
TMTaeko Matsuura
Taeko Matsuura
MSMasatoshi Saito
Masatoshi Saito
To achieve an accurate stopping power ratio (SPR) prediction in particle therapy treatment planning, we previously proposed a simple conversion to the SPR from dual-energy (DE) computed tomography (CT) data via electron density and effective atomic number ( Z eff ) calibration (DEEDZ-SPR). This study was conducted to carry out an initial implementation of the DEEDZ-SPR conversion method with a clinical treatment planning system (TPS; VQA, Hitachi Ltd., Tokyo) for proton beam therapy. Consequently, this paper presents a proton therapy plan for an anthropomorphic phantom to evaluate the stability of the dose calculations obtained by the DEEDZ-SPR conversion against the variation of the calibration phantom size. Dual-energy x-ray CT images were acquired using a dual-source CT (DSCT) scanner. A single-energy CT (SECT) scan using the same DSCT scanner was also performed to compare the DEEDZ-SPR conversion with the SECT-based SPR (SECT-SPR) conversion. The scanner-specific parameters necessary for the SPR calibration were obtained from the CT images of tissue substitutes in a calibration phantom. Two calibration phantoms with different sizes (a 33 cm diameter phantom and an 18 cm diameter phantom) were used for the SPR calibrations to investigate the beam-hardening effect on dosimetric uncertainties. Each set of calibrated SPR data was applied to the proton therapy plan designed using the VQA TPS with a pencil beam algorithm for the anthropomorphic phantom. The treatment plans with the SECT-SPR conversion exhibited discrepancies between the dose distributions and the dose-volume histograms (DVHs) of the 33 cm and 18 cm phantom calibrations. In contrast, the corresponding dose distributions and the DVHs obtained using the DEEDZ-SPR conversion method coincided almost perfectly with each other. The DEEDZ-SPR conversion appears to be a promising method for providing proton dose plans that are stable against the size variations of the calibration phantom and the patient.

21 June 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
STSodai Tanaka
Sodai Tanaka
TITaku Inaniwa
Taku Inaniwa
SMShunya Matsuba
Shunya Matsuba
Objective. In charged-particle therapy, a ripple filter (RiFi) is used for broadening the Bragg peak in the beam direction. A conventional RiFi consists of plates with a fine ridge and groove structure. The construction of the RiFi has been a time-consuming and costly task. In this study, we developed a simple RiFi made of multi-layered metal mesh (mRiFi), with which the Bragg peak is broadened due to structural randomness, similar to what occurs for the already proposed RiFi with porous material. Approach . The mRiFi was constructed by stacking commercially available metal meshes at random positions and angles. The mRiFi was inexpensive to fabricate due to its high availability and low machining accuracy. The Bragg peak width modulated by the mRiFi can be uniquely determined by the wire material, wire diameter, wire-to-wire spacing of the metal mesh, and the number of mesh sheets. We fabricated four mRiFis consisting of 10, 20, 30, and 40 layers of stainless steel meshes with a wire diameter of 0.1 mm and a wire-to-wire spacing of 0.508 mm. Main results. Using the mRiFis consisting of 10, 20, 30, and 40 mesh sheets, we succeeded in broadening the Bragg peak following the normal distribution with the respective standard deviation σ values of 0.83, 1.15, 1.41, and 1.56 mm in water in experimental planar-integrated depth dose measurements with 140.3 MeV u −1 carbon-ion beams. The effect of range broadening with the mRiFi was independent of its lateral position, and the measurement of the surface dose using radiochromic films showed no severe inhomogeneity with a homogeneity index greater than 0.3 caused by the mRiFis. Significance. The developed mRiFi can be used as a RiFi in charged-particle therapy. The mRiFi has three advantages: high supply stability of the material for manufacturing it, easy fabrication, and low cost.

5 November 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
TYTakaaki Yoshimura
Takaaki Yoshimura
SSShinichi Shimizu
Shinichi Shimizu
THTakayuki Hashimoto
Takayuki Hashimoto
KNKentaro Nishioka
Kentaro Nishioka
NKNorio Katoh
Norio Katoh
HSHiroki Shirato
Hiroki Shirato
A synchrotron‐based real‐time image gated spot‐scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra‐field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron‐based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron‐based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra‐field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron‐based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra‐field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.

10 July 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
STSodai Tanaka
Sodai Tanaka
TITaku Inaniwa
Taku Inaniwa
Objective. A simple, low-cost ripple filter consisting of multiple mesh sheets (mRiFi) was previously developed to reproducibly widen the Bragg peak of heavy-ion beams. To fabricate the mRiFi, the mRiFi parameters such as the wire material, wire diameter, wire spacing, and number of mesh sheets had to be determined. However, it was unclear how these parameters contribute to shifting and widening of the Bragg peak as well as to lateral spreading of the beam passing through the mRiFi. The purposes of this study were to clarify the contributions and to propose a recipe for fabricating a mRiFi with the desired performance values. Approach. We established an analytical calculation method to estimate shifting and widening of the Bragg peak and lateral spreading of heavy-ion beams passing through the mRiFi for given mRiFi parameter values. We also performed Monte Carlo simulations to validate the analytical calculation method. The recipe for fabricating the mRiFi with desired performances was established based on the analytical calculation method. Using the recipe, we fabricated the mRiFi for multi-ion therapy and evaluated its performance through demonstration experiments with helium-, carbon-, oxygen-, and neon-ion beams. Main results. The difference between the results of the Monte Carlo simulation and the analytical calculation was less than 0.4 mm for the peak shift, 0.15 mm for the peak width, and less than 0.11 mm for the lateral beam size which validated the analytical calculation method. The experimentally observed shift and width of the Bragg peak were consistent with the analytical calculations. Significance. We proposed a method to determine mRiFi parameters for fabricating a mRiFi with a desired performance, i.e. adequate widening of the Bragg peak with an acceptable peak shift and lateral beam spread. The proposed method allows anyone to fabricate a simple and low-cost mRiFi satisfying desired specifications.

16 March 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
YNYusuke Nomura
Yusuke Nomura
STSodai Tanaka
Sodai Tanaka
JWJeff Wang
Jeff Wang
HSHiroki Shirato
Hiroki Shirato
SSShinichi Shimizu
Shinichi Shimizu
LXLei Xing
Lei Xing
Integrated-type proton computed tomography (pCT) measures proton stopping power ratio (SPR) images for proton therapy treatment planning, but its image quality is degraded due to noise and scatter. Although several correction methods have been proposed, techniques that include estimation of uncertainty are limited. This study proposes a novel uncertainty-aware pCT image correction method using a Bayesian convolutional neural network (BCNN). A DenseNet-based BCNN was constructed to predict both a corrected SPR image and its uncertainty from a noisy SPR image. A total 432 noisy SPR images of 6 non-anthropomorphic and 3 head phantoms were collected with Monte Carlo simulations, while true noise-free images were calculated with known geometric and chemical components. Heteroscedastic loss and deep ensemble techniques were performed to estimate aleatoric and epistemic uncertainties by training 25 unique BCNN models. 200-epoch end-to-end training was performed for each model independently. Feasibility of the predicted uncertainty was demonstrated after applying two post-hoc calibrations and calculating spot-specific path length uncertainty distribution. For evaluation, accuracy of head SPR images and water-equivalent thickness (WET) corrected by the trained BCNN models was compared with a conventional method and non-Bayesian CNN model. BCNN-corrected SPR images represent noise-free images with high accuracy. Mean absolute error in test data was improved from 0.263 for uncorrected images to 0.0538 for BCNN-corrected images. Moreover, the calibrated uncertainty represents accurate confidence levels, and the BCNN-corrected calibrated WET was more accurate than non-Bayesian CNN with high statistical significance. Computation time for calculating one image and its uncertainties with 25 BCNN models is 0.7 s with a consumer grade GPU. Our model is able to predict accurate pCT images as well as two types of uncertainty. These uncertainties will be useful to identify potential cause of SPR errors and develop a spot-specific range margin criterion, toward elaboration of uncertainty-guided proton therapy.