A new dosimeter for total ionizing dose that is based on a floating gate MOSFET is presented. The chip incorporates a reference standard MOSFET for temperature compensation and front-end electronics to provide manageable output signals. The floating gate is automatically recharged through an included charge pump circuitry, thus its operating range is spread without affecting the sensitivity. Two different sensitivity configurations are included in the same chip, so the dosimeter can be used under different radiation environments. An initial characterization has been carried out in order to evaluate its suitability for space missions. The results show that the proposed floating gate radiation dosimeter is adequate for space missions with levels of total ionizing dose up to at least 10 krad(Si).
The aim of electrocardiogram (ECG) compression is to reduce the amount of data as much as possible while preserving the significant information for diagnosis. Objective metrics that are derived directly from the signal are suitable for controlling the quality of the compressed ECGs in practical applications. Many approaches have employed figures of merit based on the percentage root mean square difference (PRD) for this purpose. The benefits and drawbacks of the PRD measures, along with other metrics for quality assessment in ECG compression, are analysed in this work. We propose the use of the root mean square error (RMSE) for quality control because it provides a clearer and more stable idea about how much the retrieved ECG waveform, which is the reference signal for establishing diagnosis, separates from the original. For this reason, the RMSE is applied here as the target metric in a thresholding algorithm that relies on the retained energy. A state of the art compressor based on this approach, and its PRD-based counterpart, are implemented to test the actual capabilities of the proposed technique. Both compression schemes are employed in several experiments with the whole MIT–BIH Arrhythmia Database to assess both global and local signal distortion. The results show that, using the RMSE for quality control, the distortion of the reconstructed signal is better controlled without reducing the compression ratio.
6 June 2012 in IEEE Transactions on Nuclear Science
A new proton monitor on board NANOSAT-1B—Las Dos Torres (translated: The Two Towers)—and its preliminary results after two years in orbit and its intercomparison to a RadFET and to trapped proton models are presented. This satellite was fully developed by INTA (National Institute of Aerospace Technology, Spain) and was launched on July 29, 2009. The instrument includes two stacks of radiation-sensing elements: the “dark” and “light” towers. The displacement damage was measured, both through the increase of a photodiode dark current (“dark tower”) and the decrease of the photocurrent signal in a photodiode optically linked to light emitting diodes (“light tower”). The instrument was also designed to monitor the ionization current of the photodiodes and the variations in the proton flux in the South Atlantic Anomaly.
1 August 2011 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
The aim of electrocardiogram (ECG) compression is to achieve as much compression as possible while the significant information is preserved in the reconstructed signal. Lossy thresholding-based compressors have shown good performance needing low computational resources. In this work, two compression schemes that include nearly perfect reconstruction cosine modulated filter banks for the signal decomposition are proposed. They are evaluated for highly reliable applications, where the reconstructed signal must be very similar to the original. The whole MIT-BIH Arrhythmia Database and suitable metrics are used in the assessment, to obtain representative results. Results show that the proposed compressors yield better performance than discrete wavelet transform-based techniques, when high quality requirements are imposed.
The time to first fix (TTFF) measures the time elapsed by a global navigation satellite system (GNSS) receiver from switch-on to provision of a navigation solution. This parameter is crucial for applications where a position, within an acceptable error, is needed as soon as possible after turning the device on. The quality of the TTFF depends mainly on the receiver, the environment, and the GNSS satellites employed. Although all four available GNSSs (BeiDou, Galileo, GLONASS, and GPS) are complementary, their constellations and signals differ, providing different TTFF performances. This becomes even more relevant in hostile environments, where the TTFF degrades from nominal results. In this work, the robustness of the signals of the four GNSSs against different levels of harshness and its influence on the TTFF performance are evaluated in a comparative way. For this purpose, a typical scenario for mass-market GNSS applications, involving cold-start conditions, single-frequency signals, and a low-cost receiver, is considered. The results indicate that GPS provides the most robust TTFF, followed by GLONASS (although at the expense of positioning accuracy), BeiDou, and Galileo, in that order.
Several samples of NdFeB and SmCo permanent magnets have been irradiated with gamma rays up to different total irradiation doses until 1Mrad(Si). Magnetic properties of the samples have been measured at different temperatures before and after irradiation. The modifications of the magnetic parameters are presented. From these results it is highlighted which permanent magnets show more resistance to radiation and are more suitable to be included in devices for space applications or high radiation environments.