Vicet Aurore

Vicet Aurore


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Applied Energy
Verified
Journal Article
Closed access
MCM. Clairotte
M. Clairotte
TAT.W. Adam
T.W. Adam
AZA.A. Zardini
A.A. Zardini
UMU. Manfredi
U. Manfredi
GMG. Martini
G. Martini
CAC. Astorga
C. Astorga

1 June 2024 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
Kumar KinjalkKumar Kinjalk
Kumar Kinjalk
FPFrancesco Paciolla
Francesco Paciolla
BSBo Sun
Bo Sun
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
GMGiansergio Menduni
Giansergio Menduni
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
The precise detection of volatile organic compounds plays a pivotal role in addressing environmental concerns, industrial safety, and medical diagnostics. The accurate identification and quantification of these compounds because of their ubiquity and potential health hazards has fueled the development of advanced sensing technologies. This work presents a sensing system in the realm of long-wavelength infrared spectroscopy for achieving enhanced selectivity and sensitivity of benzene, toluene, and propane detection through quartz-enhanced photoacoustic spectroscopy. High-resolution gas spectroscopy is made possible by the use of specially designed InAs/AlSb-based quantum cascade lasers, emitting in the wavelength range 13–15 μm, and quartz tuning forks. The sensor system, characterized by its robustness and precision, demonstrates exceptional capabilities in benzene, toluene, and propane detection. The system's capacity for practical applications in environmental monitoring and medical diagnostics is demonstrated by its ability to distinguish these volatile organic compounds with a minimum detection limit of 113 ppb, 3 ppb, and 3 ppm for toluene, benzene, and propane at an integration time of 10 s, even in complex gas matrices. This work advances gas sensing technology while also offering insightful information on spectral interferences, a persistent problem in the field. The results usher in a new era of sophisticated and reliable gas sensing techniques meeting the growing demand for precise volatile organic compounds detectors for environmental monitoring purposes.

12 July 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
RTR. Teissier
R. Teissier
DBD. Barate
D. Barate
VAVicet Aurore
Vicet Aurore
CAC. Alibert
C. Alibert
ABA. N. Baranov
A. N. Baranov
JCJ. Cockburn
J. Cockburn
The room temperature operation of InAs∕AlSb quantum cascade lasers is reported. The structure, grown by molecular beam epitaxy on an InAs substrate, is based on a vertical transition design and a low loss n+-InAs plasmon enhanced waveguide. The lasers emitting near 4.5μm operate in pulse regime up to 300K. The threshold current density of 3.18-mm-long lasers is 1.5kA∕cm2 at 83K and 9kA∕cm2 at 300K.

1 September 2002 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
VAVicet Aurore
Vicet Aurore
DYD.A Yarekha
D.A Yarekha
APA Pérona
A Pérona
YRY Rouillard
Y Rouillard
SGS Gaillard
S Gaillard
ABA.N Baranov
A.N Baranov

30 July 2011 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
PKP. Kluczynski
P. Kluczynski
MJM. Jahjah
M. Jahjah
LNL. Nähle
L. Nähle
OAO. Axner
O. Axner
SBS. Belahsene
S. Belahsene
SLS. Lundqvist
S. Lundqvist

27 February 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
RRRoman Rousseau
Roman Rousseau
ZLZeineb Loghmari
Zeineb Loghmari
MBMichael Bahriz
Michael Bahriz
KCKaim Chamassi
Kaim Chamassi
RTRoland Teissier
Roland Teissier
VAVicet Aurore
Vicet Aurore
An off-beam quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor was designed for ethylene detection using a distributed-feedback quantum cascade laser (QCL) operating in the mid-infrared around 11 μm. The acoustic microresonator configuration was experimentally optimized using an original open-cell photoacoustic setup with a MEMS microphone. Correction factors based on theoretical acoustic models were introduced in order to accurately describe the response of millimeter-sized acoustic resonators. The optimized QEPAS sensor exhibited a limit of detection of 60 ppb for 60 s integration, giving a NNEA of 4.8 × 10−8 W·cm−1·Hz-0.5.