Andrea Zifarelli

Dr. Andrea Zifarelli

Università degli Studi di Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Analytica Chimica Acta
Verified
Journal Article
Open access
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
PPPietro Patimisco
Pietro Patimisco
Marilena GiglioMarilena Giglio
Marilena Giglio
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
HWHongpeng Wu
Hongpeng Wu
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
Multi-gas detection represents a suitable solution in many applications, such as environmental and atmospheric monitoring, chemical reaction and industrial process control, safety and security, oil&gas and biomedicine. Among optical techniques, Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) has been demonstrated to be a leading-edge technology for addressing multi-gas detection, thanks to the modularity, ruggedness, portability and real time operation of the QEPAS sensors. The detection module consists in a spectrophone, mounted in a vacuum-tight cell and detecting sound waves generated via photoacoustic excitation within the gas sample. As a result, the sound detection is wavelength-independent and the volume of the absorption cell is basically determined by the spectrophone dimensions, typically in the order of few cubic centimeters. In this review paper, the implementation of the QEPAS technique for multi-gas detection will be discussed for three main areas of applications: i) multi-gas trace sensing by exploiting non-interfering absorption features; ii) multi-gas detection dealing with overlapping absorption bands; iii) multi-gas detection in fluctuating backgrounds. The fundamental role of the analysis and statistical tools will be also discussed in detail in relation with the specific applications. This overview on QEPAS technique, highlighting merits and drawbacks, aims at providing ready-to-use guidelines for multi-gas detection in a wide range of applications and operating conditions.

9 November 2021 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
TWTingting Wei
Tingting Wei
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
SRStefano Dello Russo
Stefano Dello Russo
HWHongpeng Wu
Hongpeng Wu
GMGiansergio Menduni
Giansergio Menduni
Lei DongLei Dong
Lei Dong
Infrared laser technology over the last decades has led to an increasing demand for optical detectors with high sensitivity and a wide operative spectral range suitable for spectroscopic applications. In this work, we report on the performance of a custom quartz tuning fork used as a sensitive and broadband infrared photodetector for absorption spectroscopy. The photodetection process is based on light impacting on the tuning fork and creating a local temperature increase that generates a strain field. This light-induced, thermoelastic conversion produces an electrical signal proportional to the absorbed light intensity due to quartz piezoelectricity. A finite-element-method analysis was used to relate the energy release with the induced thermal distribution. To efficiently exploit the photo-induced thermoelastic effects in the low-absorbance spectral region of quartz also, chromium/gold layers, acting as opaque surface, have been deposited on the quartz surface. To demonstrate the flat response as photodetectors, a custom tuning fork, having a fundamental resonance frequency of 9.78 kHz and quality factor of 11 500 at atmospheric pressure, was employed as photodetector in a tunable diode laser absorption spectroscopy setup and tested with five different lasers with emission wavelength in the 1.65–10.34 μm range. A spectrally flat responsivity of ∼2.2 kV/W was demonstrated, corresponding to a noise-equivalent power of 1.5 nW/√Hz, without employing any thermoelectrical cooling systems. Finally, a heterodyne detection scheme was implemented in the tunable diode laser absorption spectroscopy setup to retrieve the resonance properties of the quartz tuning fork together with the gas concentration in a single, fast measurement.

1 June 2024 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
Kumar KinjalkKumar Kinjalk
Kumar Kinjalk
FPFrancesco Paciolla
Francesco Paciolla
BSBo Sun
Bo Sun
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
GMGiansergio Menduni
Giansergio Menduni
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
The precise detection of volatile organic compounds plays a pivotal role in addressing environmental concerns, industrial safety, and medical diagnostics. The accurate identification and quantification of these compounds because of their ubiquity and potential health hazards has fueled the development of advanced sensing technologies. This work presents a sensing system in the realm of long-wavelength infrared spectroscopy for achieving enhanced selectivity and sensitivity of benzene, toluene, and propane detection through quartz-enhanced photoacoustic spectroscopy. High-resolution gas spectroscopy is made possible by the use of specially designed InAs/AlSb-based quantum cascade lasers, emitting in the wavelength range 13–15 μm, and quartz tuning forks. The sensor system, characterized by its robustness and precision, demonstrates exceptional capabilities in benzene, toluene, and propane detection. The system's capacity for practical applications in environmental monitoring and medical diagnostics is demonstrated by its ability to distinguish these volatile organic compounds with a minimum detection limit of 113 ppb, 3 ppb, and 3 ppm for toluene, benzene, and propane at an integration time of 10 s, even in complex gas matrices. This work advances gas sensing technology while also offering insightful information on spectral interferences, a persistent problem in the field. The results usher in a new era of sophisticated and reliable gas sensing techniques meeting the growing demand for precise volatile organic compounds detectors for environmental monitoring purposes.

1 March 2020 in Photoacoustics
Verified
Journal Article
Open access
Marilena GiglioMarilena Giglio
Marilena Giglio
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
GMGiansergio Menduni
Giansergio Menduni
AEArianna Elefante
Arianna Elefante
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
Here we report on the broadband detection of nitrous oxide (N2O) and methane (CH4) mixtures in dry nitrogen by using a quartz-enhanced photoacoustic (QEPAS) sensor exploiting an array of 32 distributed-feedback quantum cascade lasers, within a spectral emission range of 1190-1340 cm-1 as the excitation source. Methane detection down to a minimum detection limit of 200 ppb at 10 s lock-in integration time was achieved. The sensor demonstrated a linear response in the range of 200-1000 ppm. Three different mixtures of N2O and CH4 in nitrogen at atmospheric pressure have been analyzed. The capability of the developed QEPAS sensor to selectively determine the N2O and CH4 concentrations was demonstrated, in spite of significant overlap in their respective absorption spectra in the investigated spectral range.

22 October 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Marilena GiglioMarilena Giglio
Marilena Giglio
PPPietro Patimisco
Pietro Patimisco
ASAngelo Sampaolo
Angelo Sampaolo
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
RBRomain Blanchard
Romain Blanchard
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
We present a gas sensing system based on quartz-enhanced photoacoustic spectroscopy (QEPAS) employing a monolithic distributed-feedback quantum cascade laser (QCL) array operated in a pulsed mode as a light source. The array consists of 32 quantum cascade lasers emitting in a spectral range from 1190 cm−1 to 1340 cm−1. The optoacoustic detection module was composed of a custom quartz tuning fork with a prong spacing of 1 mm, coupled with two micro-resonator tubes to enhance the signal-to-noise ratio. The QEPAS sensor was validated by detecting the absorption of the P- and R-branches of nitrous oxide. The measurements were performed by switching the array QCLs in sequence while tuning their operating temperature to retrieve the fine structure of the two N2O branches. A sensor calibration was performed, demonstrating a linear responsivity for N2O:N2 concentrations from 1000 down to 200 parts-per-million. With a 10 s lock-in integration time, a detection sensitivity of less than 60 parts-per-billion was achieved permitting the monitoring of nitrous oxide at global atmospheric levels.

28 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MOMariagrazia Olivieri
Mariagrazia Olivieri
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
GMGiansergio Menduni
Giansergio Menduni
Michele Di GioiaMichele Di Gioia
Michele Di Gioia
CMCristoforo Marzocca
Cristoforo Marzocca
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
A theoretical analysis and experimental investigation of the influence of gas pressure on resonance properties, namely, the quality factor and resonance frequency, of a T-shaped quartz tuning fork (QTF) is reported here. Two configurations are considered: a bare QTF, and a QTF coupled with a pair of resonator tubes (spectrophone). In both configurations, the effect of air on resonance frequency due to the additional inertia on prong motion and the influence of air damping on the quality factor, were analysed. By comparing the bare QTF and the spectrophone results, the effect of pressure on the acoustic coupling between the QTF and the tubes was theoretically modelled and then validated. The results show that acoustic coupling is strongly influenced by air pressure, leading to a shift of resonance frequency and a decrease in the quality factor up to 24%.