Dennis Johansson

Dr. Dennis Johansson

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Energy Reports
Verified
Journal Article
Open access
MAMarwan Abugabbara
Marwan Abugabbara
JLJonas Lindhe
Jonas Lindhe
Saqib JavedSaqib Javed
Saqib Javed
HBHans Bagge
Hans Bagge
DJDennis Johansson
Dennis Johansson

22 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
Kristina MjörnellKristina Mjörnell
Kristina Mjörnell
DJDennis Johansson
Dennis Johansson
HBHans Bagge
Hans Bagge
Apartments built in Sweden during the record years 1961–1975 with the aim to remedy the housing shortage and abolish poor standards, were designed for a normal-sized family of 2–4 persons. The mechanical ventilation system, if existing, was primarily designed to ensure an air exchange in the apartment according to Swedish building regulations. During the last few years, the number of overcrowded apartments has increased due to housing shortage in general but also due to migration. Another aspect is that the ventilation in many apartments built during the record years is already insufficient at normal occupant load. The question is how doubling or tripling the number of occupants and thus, the moisture load will affect the risk of bad air quality and moisture damage. To find out, simulations were made to estimate whether it is possible to obtain sufficient air quality and low risk of moisture damage by only increasing the ventilation rates in existing systems or introducing new ventilation systems with and without heat recovery and what the consequence would be in terms of the additional energy demand. Measurements from earlier studies of CO2 and moisture supply in Swedish apartment buildings were used as input data.

1 July 2019 in Energy and Buildings
Verified
Journal Article
Closed access
AHAkram Abdul Hamid
Akram Abdul Hamid
HBHans Bagge
Hans Bagge
DJDennis Johansson
Dennis Johansson

10 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
BSBranko Simanic
Branko Simanic
BNBirgitta Nordquist
Birgitta Nordquist
HBHans Bagge
Hans Bagge
DJDennis Johansson
Dennis Johansson
Literature and experience show that there are large discrepancies between the calculated and measured building energy usages, where user-related parameters are significant factors with regard to energy use in low-energy buildings. Furthermore, the difficulties encountered when quantifying these parameters compound these discrepancies. The main aim of this study was to provide feedback that would help the building industry and research communities to predict more accurately the impact of the user-related parameters on energy performance. The results of the study would, subsequently, contribute to minimizing the discrepancies between calculated and measured energy use. This article analyses simulated building energy use based on randomly chosen combinations of measured user-related parameters in three recently built low-energy schools in Sweden. The results show that energy performance can span from 30 to 160 kWh/(m² y) simply by varying the combination of previously measured user-related parameters in building energy simulations. The study shows that the set points for indoor air temperatures during the heating season and the energy required to run a demand-controlled ventilation system have an extensive influence, while tenant electricity use has a slightly lower influence on building energy use. Variations in occupancy rates and energy for hot water usage have the smallest influences on building energy use.

13 May 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AHAkram Abdul Hamid
Akram Abdul Hamid
JPJenny von Platten
Jenny von Platten
Kristina MjörnellKristina Mjörnell
Kristina Mjörnell
DJDennis Johansson
Dennis Johansson
HBHans Bagge
Hans Bagge
Recently, there has been an increase in apartments with a large number of inhabitants, i.e., high residential density. This is partly due to a housing shortage in general but also increased migration, particularly in suburbs of major cities. This paper specifies issues that might be caused by high residential density by investigating the technical parameters influenced in Swedish apartments that are likely to have high residential density. Interviews with 11 employees at housing companies were conducted to identify issues that might be caused by high residential density. Furthermore, simulations were conducted based on extreme conditions described in the interviews to determine the impact on the energy use, indoor environmental quality, and moisture loads. In addition, the impact of measures to mitigate the identified issues was determined. Measures such as demand-controlled ventilation, increase of a constant ventilation rate, and moisture buffering are shown to reduce the risk for thermal discomfort, mold growth, and diminished indoor air quality; while still achieving a lower energy use than in a normally occupied apartment. The results of this study can be used by authorities to formulate incentives and/or recommendations for housing owners to implement measures to ensure good indoor environmental quality for all, irrespective of residential density conditions.

2 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
APAlina Pasina
Alina Pasina
ACAffonso Canoilas
Affonso Canoilas
DJDennis Johansson
Dennis Johansson
HBHans Bagge
Hans Bagge
VFVictor Fransson
Victor Fransson
HDHenrik Davidsson
Henrik Davidsson
In past years, Sweden has been facing a rapid growth of photovoltaic cells, and the total PV installation capacity increased from 300 kW to 1090 MW (2006–2020). The increased number of PV users was a result of active support from the Swedish government with an aim of achieving multiple sustainable goals regarding renewable energy. This project evaluates the profitability of shared PV systems in communities of different sizes in Sweden. This study aimed to contribute to the literature by filling the research gap of presenting the financial benefits at different community scales. The electricity use profiles consisted of hourly measured electricity use that was derived from 1067 individual Swedish apartments. The profiles were then used to create multi-scaled communities with shared PV systems. The mid-market price model was implemented to simulate electricity trading among prosumers in the community using Visual Basic Applications (VBA) in MS Excel. Further, the electricity costs were used for Life Cycle Cost (LCC) assessment. To demonstrate the increase in profitability, the LCC results of households with shared PV systems were compared to households that own PV individually and households that do not own a PV system. The evaluation showed the financial benefits of shared PV systems in comparison with individually owned PV systems. This study also demonstrated the increase in profitability and the reduction in payback time for the average household if sharing a PV system as part of a larger community.