A microfluidic-based gas sensor was chosen as an alternative method to gas chromatography and mass spectroscopy systems because of its small size, high accuracy, low cost, etc. Generally, there are some parameters, such as microchannel geometry, that affect the gas response and selectivity of the microfluidic-based gas sensors. In this study, we simulated and compared 3D numerical models in both simple and serpentine forms using COMSOL Multiphysics 5.6 to investigate the effects of microchannel geometry on the performance of microfluidic-based gas sensors using multiphysics modeling of diffusion, surface adsorption/desorption and surface reactions. These investigations showed the simple channel has about 50% more response but less selectivity than the serpentine channel. In addition, we showed that increasing the length of the channel and decreasing its height improves the selectivity of the microfluidic-based gas sensor. According to the simulated models, a serpentine microchannel with the dimensions W = 3 mm, H = 80 µm and L = 22.5 mm is the optimal geometry with high selectivity and gas response. Further, for fabrication feasibility, a polydimethylsiloxane serpentine microfluidic channel was fabricated by a 3D printing mold and tested according to the simulation results.
Bacterial spores are problematic in agriculture, the food industry, and healthcare, with the fallout costs from spore-related contamination being very high. Spores are difficult to detect since they are resistant to many of the bacterial disruption techniques used to bring out the biomarkers necessary for detection. Because of this, effective and practical spore disruption methods are desirable. In this study, we demonstrate the efficiency of a compact microfluidic lab-on-chip built around a coplanar waveguide (CPW) operating at 2.45 GHz. We show that the CPW generates an electric field hotspot of ∼10 kV/m, comparable to that of a commercial microwave oven, while using only 1.2 W of input power and thus resulting in negligible sample heating. Spores passing through the microfluidic channel are disrupted by the electric field and release calcium dipicolinic acid (CaDPA), a biomarker molecule present alongside DNA in the spore core. We show that it is possible to detect this disruption in a bulk spore suspension using fluorescence spectroscopy. We then use laser tweezers Raman spectroscopy (LTRS) to show the loss of CaDPA on an individual spore level and that the loss increases with irradiation power. Only 22% of the spores contain CaDPA after exposure to 1.2 W input power, compared to 71% of the untreated control spores. Additionally, spores exposed to microwaves appear visibly disrupted when imaged using scanning electron microscopy (SEM). Overall, this study shows the advantages of using a CPW for disrupting spores for biomarker release and detection.
16 February 2021 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
The micromixer is a very common component in the state-of-the-art lab-on-chip devices and occupies large chip areas to fulfill the rather challenging process of mixing in microscales. Two various design micromixers are introduced, which show a step over efficiency in the microlevel mixing. Finite-element method (FEM) tools were utilized to assess the mixing efficiency of the presented micromixers versus common T- and zigzag-shaped mixers. Using the availability of three-dimensional printing features, the chaotic advection is maximized as a mainstream factor affecting microscale behavior of the mixer. Both FEM and experimental results prove a 95% improvement in the performance of micromixers for low Reynolds numbers at 1 versus 8 cm for conventional devices.
Mass transport, the process of delivering the analyte contained in a liquid sample to the active surface of a biosensor is one of the main factors that critically influence performance of affinity biosensors, in particular, when extremely low analyte concentrations are to be detected. Here, we present a new passive mixing microfluidics based on Zigzag microstructures incorporated into the wall of the microfluidic channel opposite the sensing surface (referred to as ZTOP) and show that this design promotes transport of analyte to the surface of the biosensor. Both numerical simulation and experimental investigation are performed for a range of Peclet numbers and analyte concentrations using the surface plasmon resonance experimental platform and streptavidin-labeled gold nanoparticles as model analyte. We show that the experimental results agree well with the theoretical predictions. We also demonstrate that the ZTOP microfluidics provides an enhancement in the analyte transport by a factor of 2.3 and 1.25 when compared to the conventional microfluidic design (smooth flat channel) and alternative mixing design (herringbone mixing structures), respectively.
13 January 2026 in Journal of Mechanical Science and Technology