Nishant V Nikam

Mr. Nishant V Nikam

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
NNNishant V Nikam
Nishant V Nikam
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
Chethan K NChethan K N
Chethan K N
LKLaxmikant G Keni
Laxmikant G Keni
SSSawan Shetty
Sawan Shetty
SBShyamasunder N Bhat
Shyamasunder N Bhat
Background/Objectives: The increasing demand for total hip arthroplasty (THA), due to aging populations and active lifestyles, necessitates advancements in implant materials and design. This review evaluates the role of surface coatings in enhancing the performance, biocompatibility, and longevity of hip implants. It addresses challenges like wear, corrosion, and infection, focusing on innovative surface engineering solutions. Methods: The review analyzes various surface modification techniques, including physical vapor deposition (PVD), chemical vapor deposition (CVD), electrophoretic deposition (EPD), plasma spraying, and ion implantation. It also examines their effectiveness in improving tribological properties, biocompatibility, and resistance to infection. Computational methods such as finite element analysis (FEA) are discussed for predicting potential coating failures. Results: The findings underscore the challenges posed by wear debris and corrosion in common configurations, like metal-on-metal (MoM) and metal-on-polyethylene (MoP). Innovative coatings, such as diamond-like carbon (DLC) films and hydroxyapatite (HA) layers, demonstrate enhanced performance by reducing friction, wear, and bacterial adhesion, while promoting osteogenic cell attachment. Surface textures and optimized tribological properties further improve implant functionality. Multifunctional coatings exhibit potential in balancing biocompatibility and infection resistance. Conclusions: Surface engineering plays a critical role in advancing next-generation hip implants. The integration of advanced coatings and surface modifications enhances implant durability, reduces complications, and improves patient outcomes. Future research should focus on combining innovative materials and computational modeling to refine coating strategies for long-term success in THA.

13 March 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
Chethan K NChethan K N
Chethan K N
NWNadine Schmidt Genannt Waldschmidt
Nadine Schmidt Genannt Waldschmidt
JCJohn Valerian Corda
John Valerian Corda
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
SSSawan Shetty
Sawan Shetty
ŞMŞenay Mihçin
Şenay Mihçin
The femur is one of the most important bone in the human body, as it supports the body’s weight and helps with movement. The aging global population presents a significant challenge, leading to an increasing demand for artificial joints, particularly in knee and hip replacements, which are among the most prevalent surgical procedures worldwide. This study focuses on hip fractures, a common consequence of osteoporotic fractures in the elderly population. To accurately predict individual bone properties and assess fracture risk, patient-specific finite element models (FEM) were developed using CT data from healthy male individuals. The study employed ANSYS 2023 R2 software to estimate fracture loads under simulated single stance loading conditions, considering strain-based failure criteria. The FEM bone models underwent meticulous reconstruction, incorporating geometrical and mechanical properties crucial for fracture risk assessment. Results revealed an underestimation of the ultimate bearing capacity of bones, indicating potential fractures even during routine activities. The study explored variations in bone density, failure loads, and density/load ratios among different specimens, emphasizing the complexity of bone strength determination. Discussion of findings highlighted discrepancies between simulation results and previous studies, suggesting the need for optimization in modelling approaches. The strain-based yield criterion proved accurate in predicting fracture initiation but required adjustments for better load predictions. The study underscores the importance of refining density-elasticity relationships, investigating boundary conditions, and optimizing models through in vitro testing for enhanced clinical applicability in assessing hip fracture risk. In conclusion, this research contributes valuable insights into developing patient-specific FEM bone models for clinical hip fracture risk assessment, emphasizing the need for further refinement and optimization for accurate predictions and enhanced clinical utility.

30 December 2025 in Surgeries
Verified
Journal Article
Open access
PDF file
NNNishant V Nikam
Nishant V Nikam
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
SSSawan Shetty
Sawan Shetty
SBShyamasunder N Bhat
Shyamasunder N Bhat
LKLaxmikant G Keni
Laxmikant G Keni
ŞMŞenay Mihçin
Şenay Mihçin
Total hip arthroplasty (THA) is a transformative procedure for managing severe hip disorders, yet implant longevity remains a critical challenge, particularly for younger, active patients. Wear-related complications are a leading cause of revision surgery, emphasizing the need for optimized design and material performance. This systematic review aims to synthesize evidence on the wear behavior, material properties, and design parameters of hip implants with a focus on finite element analysis (FEA)-based predictive approaches. A comprehensive literature search was conducted across Scopus, PubMed, ScienceDirect, MDPI, and Cochrane databases following PRISMA guidelines. Studies published between 2010 and 2025 were included if they addressed THA biomechanics, wear analysis, or material optimization using FEA, hip simulators, or radiostereometric techniques. Key findings reveal that larger femoral heads, while reducing contact pressure, increase wear due to greater sliding distance. Gravimetric wear rates ranged from 3.15 ± 0.27 mg/Mc to 2.18 ± 0.31 mg/Mc, while linear and volumetric wear reached 0.0375 mm/Mc and 33.6 mm3/Mc, respectively. Stress analysis showed custom stems exhibited markedly lower von Mises stress (194.9 MPa) compared to standard designs (664.3 MPa), and fatigue assessments confirmed a factor of safety > 1 across profiles. Patient-specific factors, such as body weight, significantly influenced wear with a 26% increase in metal wear observed between 100 kg and 140 kg. This systematic review synthesizes current research on total hip arthroplasty, emphasizing biomechanical and material factors critical for implant longevity and patient care. It uniquely integrates FEA-based wear prediction with clinical implications, bridging computational modeling, geometry optimization, and material performance to provide actionable insights for next-generation, patient-specific hip implant design.

12 September 2026 in Discover Materials
Verified
Journal Article
Open access
PDF file
DNDsouza Neel Noel
Dsouza Neel Noel
Chethan K NChethan K N
Chethan K N
NNNishant V Nikam
Nishant V Nikam
LKLaxmikant G Keni
Laxmikant G Keni
Satish Shenoy B.Satish Shenoy B.
Satish Shenoy B.
SBShyamasunder N Bhat
Shyamasunder N Bhat
Total hip arthroplasty (THA) remains a widely performed orthopaedic intervention; however, implant wear and limited longevity continue to drive revision surgeries, increasing both clinical burden and healthcare costs. This study presents a computational biomechanics framework to evaluate the influence of advanced surface coatings on wear behaviour and long-term performance of hip prostheses under physiological loading conditions. A three-dimensional finite element model of a femoral head–acetabular liner system was developed and subjected to dynamic gait cycle loading. Wear prediction was performed using an Archard-based model integrated within the simulation environment to quantify material loss over time. Three commonly used coatings—diamond-like carbon (DLC), titanium nitride (TiN), and aluminium oxide (Al₂O₃)—were systematically analysed in comparison with conventional bearing surfaces. The results demonstrate significant variation in contact stress distribution and wear rates across coating materials, with DLC-coated interfaces exhibiting the lowest wear and improved stress uniformity. TiN coatings showed moderate performance enhancement, while Al₂O₃ exhibited comparatively higher wear under cyclic loading conditions. The findings highlight the critical role of surface engineering in extending implant lifespan and reducing failure risk. By integrating computational modelling with wear prediction under realistic physiological conditions, this study provides a scalable approach for optimizing orthopaedic implant design. The proposed framework contributes to the development of durable and resource-efficient medical devices, supporting improved patient outcomes and advancing sustainable healthcare systems.