This study investigates the vibration and noise characteristics of oil-immersed power transformers, with a particular focus on the influence of transformer oil on structural dynamics and acoustic emission. The research integrates multi-physics modelling, finite-element simulation, and field measurements to analyze the vibration transmission paths from the core and windings to the tank wall. A fluid–structure interaction (FSI) model is developed to account for the damping effect of insulating oil, and a correction factor is introduced to adjust modal parameters. Simulation results reveal that oil significantly enhances vibration propagation, especially in the vertical direction, while structural ribs and clamping configurations affect local vibration intensity. Noise simulations show that magnetostriction is the dominant source of audible sound, with harmonic components sensitive to load and voltage variations. Experimental validation using a portable sound level meter confirms the simulation trends and highlights the spatial variability of acoustic pressure. The findings provide a theoretical and practical basis for optimizing sensor placement and developing voiceprint-based diagnostic tools for transformer condition monitoring.
Aiming at the problems of low thermal analysis efficiency and high computational cost of traditional computational fluid dynamics (CFD) methods for modular fault-tolerant permanent magnet synchronous motors (MFT-PMSMs) under complex working conditions, this paper proposes a fast modeling and calculation method of motor temperature field based on a high-efficiency and high-precision network algorithm. In this method, the physical structure of the motor is equivalent to a parameterized network model, and the computational efficiency is significantly improved by model partitioning and Fourth-order Runge Kutta method. The temperature change of the cooling medium is further considered, and the temperature rise change of the motor at different spatial positions is effectively considered. Based on the finite element method (FEM), the space loss distribution under rated, single-phase open circuit and overload conditions is obtained and mapped to the thermal network nodes. Through the transient thermal network solution, the rapid calculation of the temperature rise law of key components such as windings and permanent magnets is realized. The accuracy of the thermal network model was verified by using fluid-structure coupling simulation and prototype test for temperature analysis. This method provides an efficient tool for thermal safety assessment and optimization in the motor fault-tolerant design stage, especially for heat capacity check under extreme conditions and fault modes.
As applications like electric vehicles, all-electric ships, and all-electric aircraft continue to evolve, Noise, Vibration, and Harshness (NVH) issues have garnered extensive attention. However, as the core of the power system, permanent magnet synchronous motors (PMSMs) still lack control algorithms that consider vibration problems. Therefore, this paper proposes a model-based predictive vibration suppression algorithm to suppress the PMSM vibration. Firstly, this paper explores the influence of armature currents on vibration by analyzing the vibration characteristics of PMSMs, and proposes a minimum vibration current model. On this basis, according to the torque conditions required for the stable operation of the motor, a model-based predictive vibration suppression algorithm is designed. Finally, the effectiveness of the proposed algorithm is verified through prototype experiments.
In CNC machines, the temperature field analysis of spindle servo permanent magnet motors (SSPMMs) under rated load, overload, and weak magnetic conditions is critical for ensuring stable operation and machining accuracy. This paper proposes a temperature calculation method for SSPMMs based on the thermal network method, which is used to quickly evaluate the temperature performance of SSPMMs under different operating conditions during design. This method can calculate the steady-state or transient temperature rise under different operating conditions. First, the electromagnetic performance and heat sources of the SSPMMs were analyzed. Then, based on the thermal network method, the equivalent thermal resistances and equivalent heat dissipation coefficients of the motor components were calculated. By iterating the heat balance equation or solving the heat conduction equation for different operating conditions, the temperature distribution of SSPMMs under different operating conditions was obtained. The accuracy of the thermal network model was validated through temperature analysis using fluid–structure interaction simulations and prototype testing. The results show that the relative error between the winding temperature calculated by the proposed equivalent thermal network model and the measured temperature under different operating conditions is less than 5%. This paper provides a theoretical basis for the thermal management of SSPMM, which can quickly and accurately evaluate the temperature rise in the motor during design.
The force ripple of a permanent magnet synchronous linear motor (PMSLM) caused by multi-source disturbances in practical applications seriously restricts its high-precision motion control performance. The traditional single-mechanism model has difficulty fully characterizing the nonlinear disturbance factors, while the data-driven method has real-time limitations. Therefore, this paper proposes a hybrid modeling framework that integrates the physical mechanism and measured data and realizes the dynamic compensation of the force ripple by constructing a collaborative suppression algorithm. At the mechanistic level, based on electromagnetic field theory and the virtual displacement principle, an analytical model of the core disturbance terms such as the cogging effect and the end effect is established. At the data level, the acceleration sensor is used to collect the dynamic response signal in real time, and the data-driven ripple residual model is constructed by combining frequency domain analysis and parameter fitting. In order to verify the effectiveness of the algorithm, a hardware and software experimental platform including a multi-core processor, high-precision current loop controller, real-time data acquisition module, and motion control unit is built to realize the online calculation and closed-loop injection of the hybrid compensation current. Experiments show that the hybrid framework effectively compensates the unmodeled disturbance through the data model while maintaining the physical interpretability of the mechanistic model, which provides a new idea for motor performance optimization under complex working conditions.
Temperature monitoring underpins the protection and condition assessment of distribution transformers, whose dominant failure mode is overheating-induced insulation aging; this makes temperature data the prime target of false data injection (FDI) attacks. Because FDI acts on data rather than on the physical asset, this paper exploits the winding structure, which data injection cannot alter, as a physical trust anchor: a structural fingerprint is extracted from port measurements through frequency-dependent harmonic resistance; the systematic temperature-response differences between wire-wound and foil-wound windings build an independent physical cross-check channel; and a lightweight PBFT consortium blockchain notarizes the fingerprint baseline so that a compromised local database cannot rewrite it. Structural, physical, and command consistency indicators classify input-, output-, and model-parameter-tampering attacks. Finite-element simulations and 100-round randomized attack tests show a 9.6% structural temperature deviation that provides a clear physical screening margin: the three attack types are detected and classified within 4 s at a 100% detection rate (95% CI [96.4, 100]%) and a 0.3% false-alarm rate, while a stealthy ramp injection is caught after about 105 min and a sub-threshold constant offset is caught by trend monitoring in about 4 h. A seven-node chain implemented with real ECDSA-secp256k1 signatures achieves 0.42–0.90 s finality per notarization, 8.9–19.0 notarizations/s, and a 0.47 s view change, two orders of magnitude above the field notarization demand, meeting lightweight deployment requirements.