This study investigates the vibration and noise characteristics of oil-immersed power transformers, with a particular focus on the influence of transformer oil on structural dynamics and acoustic emission. The research integrates multi-physics modelling, finite-element simulation, and field measurements to analyze the vibration transmission paths from the core and windings to the tank wall. A fluid–structure interaction (FSI) model is developed to account for the damping effect of insulating oil, and a correction factor is introduced to adjust modal parameters. Simulation results reveal that oil significantly enhances vibration propagation, especially in the vertical direction, while structural ribs and clamping configurations affect local vibration intensity. Noise simulations show that magnetostriction is the dominant source of audible sound, with harmonic components sensitive to load and voltage variations. Experimental validation using a portable sound level meter confirms the simulation trends and highlights the spatial variability of acoustic pressure. The findings provide a theoretical and practical basis for optimizing sensor placement and developing voiceprint-based diagnostic tools for transformer condition monitoring.
As applications like electric vehicles, all-electric ships, and all-electric aircraft continue to evolve, Noise, Vibration, and Harshness (NVH) issues have garnered extensive attention. However, as the core of the power system, permanent magnet synchronous motors (PMSMs) still lack control algorithms that consider vibration problems. Therefore, this paper proposes a model-based predictive vibration suppression algorithm to suppress the PMSM vibration. Firstly, this paper explores the influence of armature currents on vibration by analyzing the vibration characteristics of PMSMs, and proposes a minimum vibration current model. On this basis, according to the torque conditions required for the stable operation of the motor, a model-based predictive vibration suppression algorithm is designed. Finally, the effectiveness of the proposed algorithm is verified through prototype experiments.
In CNC machines, the temperature field analysis of spindle servo permanent magnet motors (SSPMMs) under rated load, overload, and weak magnetic conditions is critical for ensuring stable operation and machining accuracy. This paper proposes a temperature calculation method for SSPMMs based on the thermal network method, which is used to quickly evaluate the temperature performance of SSPMMs under different operating conditions during design. This method can calculate the steady-state or transient temperature rise under different operating conditions. First, the electromagnetic performance and heat sources of the SSPMMs were analyzed. Then, based on the thermal network method, the equivalent thermal resistances and equivalent heat dissipation coefficients of the motor components were calculated. By iterating the heat balance equation or solving the heat conduction equation for different operating conditions, the temperature distribution of SSPMMs under different operating conditions was obtained. The accuracy of the thermal network model was validated through temperature analysis using fluid–structure interaction simulations and prototype testing. The results show that the relative error between the winding temperature calculated by the proposed equivalent thermal network model and the measured temperature under different operating conditions is less than 5%. This paper provides a theoretical basis for the thermal management of SSPMM, which can quickly and accurately evaluate the temperature rise in the motor during design.
In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly rely on black-box electromagnetic transient simulations or simplified magnetization models, lacking analytical approaches that account for hysteresis and residual magnetism, and therefore fail to accurately characterize the coupling mechanism between physical transients and information-layer dynamics. To address this issue, an analytical transient model for three-phase transformer reclosing is established based on the Jiles–Atherton theory, in which the hysteresis loop and residual magnetism are embedded into the electromagnetic transient process as a differential–algebraic equation (DAE) set, and the semi-analytical dependence of the inrush peak, harmonic characteristics, and decay law on the residual flux and closing angle is derived. On this basis, an inrush-feature-driven probability model of protection misjudgment is constructed, a CPPS cascading failure propagation model incorporating physical–information state transitions is developed, and an adaptive reclosing recovery control strategy based on the node fault-state reachability is proposed. Simulations on the IEEE 39-bus system show that the proposed model accurately reproduces the quantitative influence of hysteresis residual magnetism on inrush characteristics (the peak error is within 10% compared with measured/detailed simulation results), and the proposed control strategy reduces the misjudgment rate per reclosing operation from 6.78% to 1.18% (a reduction of approximately 83%) and the post-recovery load loss from 0.182% to 0.001%, compared with the conventional reclosing scheme, significantly improving the resilience and recovery efficiency of the CPPS.