The vibration and noise are a serious problem for large power transformers. The core vibration, as the noise source, is very important to calculate accurately. For the transformers with tanks, vibration calculation is very complicated, considering the complicated propagation path of vibration in the tank and the transformer oil. This paper provides a novel approach to investigate the core vibration of the DFP-270 000/500 type super high-voltage generator transformer. Based on the vibration acoustic coupling calculation, the damping coefficient of the core vibration of the transformer is obtained, and the magnetic structural coupling analysis is used for the vibration of the transformer core. To validate the feasibility and applicability of the proposed method, the numerical results obtained from the proposed method are compared with those of experimental ones.
14 March 2023 in IEEE Transactions on Industry Applications
Digital twin technology provides insight to solve the problems of state monitoring and life evaluation of electromagnetic devices. When performing digital twin system design, it is necessary to face the challenges of multi-physical field and multi-scale modeling, dynamic time-varying parameters, and data interaction. In this paper, a digital twin system design scheme for DC contactors is proposed. The modeling approach describes and defines the model at three levels: geometric, mechanistic, and data. Based on the constructed model, the knowledge acquisition and data mapping processes of the contactor operation process are investigated. In addition, the fidelity assessment method of the digital twin model is given in order to evaluate the validity of the constructed model. The empirical validation shows that the proposed digital twin high-fidelity modeling method is effective and the model can be evaluated.
18 January 2019 in IEEE Transactions on Applied Superconductivity
Winding buckling is a common and complex type of transformer failure. The commonly used method for calculating the buckling strength of transformer windings does not take into account the factors of plastic deformation and thermal effect. Therefore, in the stability analysis of the winding, the stress process of the default winding is ideal elastic. Even if some transformer windings meet the design standards, there is still the risk of instability in reality. A method for analyzing the buckling strength of transformer windings based on electromagnetic thermal structure coupling method is presented in this paper. Through a transformer example, the fault current, leakage magnetic field and electromagnetic force of transformer are analyzed by field circuit coupling method. A model of the relationship between temperature and yield strength is established, and the temperature rise and ultimate instability load of transformer windings are analyzed by finite element method and experiment. The influence of plastic deformation and thermal effect on the ultimate instability load is considered. The results show that plastic deformation and temperature rise should not be ignored in the buckling strength analysis of transformer windings. The research results have certain reference value for transformer design.
This study investigates the vibration and noise characteristics of oil-immersed power transformers, with a particular focus on the influence of transformer oil on structural dynamics and acoustic emission. The research integrates multi-physics modelling, finite-element simulation, and field measurements to analyze the vibration transmission paths from the core and windings to the tank wall. A fluid–structure interaction (FSI) model is developed to account for the damping effect of insulating oil, and a correction factor is introduced to adjust modal parameters. Simulation results reveal that oil significantly enhances vibration propagation, especially in the vertical direction, while structural ribs and clamping configurations affect local vibration intensity. Noise simulations show that magnetostriction is the dominant source of audible sound, with harmonic components sensitive to load and voltage variations. Experimental validation using a portable sound level meter confirms the simulation trends and highlights the spatial variability of acoustic pressure. The findings provide a theoretical and practical basis for optimizing sensor placement and developing voiceprint-based diagnostic tools for transformer condition monitoring.
Aiming at the problems of low thermal analysis efficiency and high computational cost of traditional computational fluid dynamics (CFD) methods for modular fault-tolerant permanent magnet synchronous motors (MFT-PMSMs) under complex working conditions, this paper proposes a fast modeling and calculation method of motor temperature field based on a high-efficiency and high-precision network algorithm. In this method, the physical structure of the motor is equivalent to a parameterized network model, and the computational efficiency is significantly improved by model partitioning and Fourth-order Runge Kutta method. The temperature change of the cooling medium is further considered, and the temperature rise change of the motor at different spatial positions is effectively considered. Based on the finite element method (FEM), the space loss distribution under rated, single-phase open circuit and overload conditions is obtained and mapped to the thermal network nodes. Through the transient thermal network solution, the rapid calculation of the temperature rise law of key components such as windings and permanent magnets is realized. The accuracy of the thermal network model was verified by using fluid-structure coupling simulation and prototype test for temperature analysis. This method provides an efficient tool for thermal safety assessment and optimization in the motor fault-tolerant design stage, especially for heat capacity check under extreme conditions and fault modes.