In practical engineering, due to the residual magnetism in the iron core of the converter transformer, the inrush current is generated in the case of no-load closing, and the inrush current leads to an oil flow surge inside the converter transformer. Under the influence of oil flow, the gas relay plate will be deflected, and when the deflection angle is too large, the gas relay will malfunction. Because of the lacking research on the influence of the misoperation of the gas relay under the excitation inrush of the converter transformer, it is difficult to effectively suppress the misoperation of gas relay under inrush current. Therefore, the finite element model of the electromagnetic hydraulic coupling of the converter transformer is established in this paper to obtain the oil flow velocity through the gas relay under the inrush current. A fluid–solid coupling model was established inside the gas relay to study the deflection characteristics of the baffle of the gas relay under the inrush current, and the relationship between the inrush current amplitude and the deflection angle of the baffle was mathematically fitted to effectively predict whether the gas relay has the risk of misoperation. From the experimental results, it can be seen that when the amplitude of the inrush current exceeds 6.37 kA, the gas relay will have the risk of misoperation. Finally, the influence of oil flow impact on the gas relay baffle under multiple cycles is considered. The results can provide an effective reference for analyzing the diagnosis of gas relay misoperation under the effect of inrush current.
The residual magnetism of the iron core of power transformers can cause an excitation inrush current, posing a threat to the safe and stable operation of the power grid. This paper proposes a transformer remanence measurement method based on a demagnetization hysteresis loop to address the problems of large errors, complex operation, and poor universality in existing remanence measurement methods. This method is designed for off-grid transformers to avoid potential interference to the power grid caused by current pulses during the measurement process. This method constructs an RLC oscillation circuit that utilizes capacitor energy storage and iron core magnetic field energy conversion, combined with the dynamic characteristics of hysteresis loops, to achieve accurate measurement of residual magnetism and synchronous demagnetization. The effectiveness of this method has been verified through residual magnetism measurement experiments on ring transformers and large converter transformers, and it can be applied in specific engineering practice operations. Theoretical analysis shows that the charging range of energy storage capacitors is affected by the hysteresis characteristics of the iron core and the saturation magnetic flux, and the residual magnetization value can be directly calculated based on the difference in the intersection point of the longitudinal axis of the demagnetization hysteresis loop. Simulation and experimental results show that the measurement error of the proposed method is less than 5%—significantly better than traditional methods. This method does not require complex control strategies, has high precision and efficiency, and can provide reliable technical support for residual magnetism detection and suppression of off-grid power transformers.
An inrush current will be generated inside a converter transformer during no-load switching on or off. The inrush current will cause severe vibration of the winding and other components of the converter transformer. However, the current research on the vibration characteristics caused by the inrush current is insufficient, and the influence of the converter transformer components cannot be effectively evaluated. Therefore, this paper discusses the building of an electromagnetic transient model of no-load closing of a conventional DC converter station, and analyzes the time–frequency characteristics of the inrush current under different working conditions. The finite element model based on the actual converter transformer was built and verified. The vibration characteristics of some converter transformer components under excitation of the inrush current were studied. The research results can monitor the vibration of a converter transformer under different working conditions, and can avoid the damage of converter transformer components caused by an excessive inrush current.