Jing Zhou

Dr. Jing Zhou

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJing Zhou
Jing Zhou
KQKecheng Qiu
Kecheng Qiu
BDBowen Deng
Bowen Deng
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
GYGuoqing Ye
Guoqing Ye
Accurate measurement of buried depth of rebars can effectively judge the durability of the Reinforced Concrete (RC) structure. However, most of the existing measurement methods cannot determine the deflection of rebar and do not consider the influence of factors such as the diameter and spacing of rebars, which resulting in low buried depth measurement accuracy. Therefore, this article takes the vertical rebars in concrete pole as the research object, and proposes a non-destructive method for location and buried depth measurement based on the magnetization effect. First, this article analyzes the influence of the magnetization effect excited by the rebars on the original magnetic field, and then designs the sensor layout to measure the magnetic induction intensity at different positions. Secondly, the central axis position and deflection angle of rebars are determined through comparing the measured data, and the buried depth is derived by applying the Support Vector Regression (SVR) algorithm. In addition, the proposed method is verified through simulation and experiments. Finally, this article discusses the influence of the diameter and spacing of rebars on the buried depth measurement, and uses the influencing factors as the inputs of the SVR algorithm model to correct the prediction results, which effectively reduces the maximum measurement error from 2.15mm to 0.36mm.

1 March 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JZJing Zhou
Jing Zhou
PGPengfei Gan
Pengfei Gan
HZHui Zhao
Hui Zhao
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
JJJun Jun
Jun Jun
Air gap defects in solid insulation of power equipment can cause partial discharge. Temperature, as an important characterization of partial discharge, can be used as a criterion for the deterioration degree of air gap defects to some extent. In this paper, the temperature characterization of air gap discharge is studied. A plasma-kinetics-based dielectric barrier discharge model is constructed. The calculation method of air gap discharge heat source under power frequency voltage is presented. Moreover, the influence of voltage amplitude and gap thickness on temperature is studied. Obtained results indicate that under the power frequency voltage, Joule (Ohmic) heat contributes 90% to the heat source, and O4+ and O2+ and electron e are the main contributors to Joule (Ohmic) heat. O4+ is also the dominant ion in the mixed gas. As the discharge progressed, O4+ almost all clustered near the instantaneous cathode. The O2+ density generally depends on the electron density, but compared with the electron, the spatial distribution of O2+ density is slightly shifted to the instantaneous cathode. The discharge heat source is positively correlated with the air gap thickness and the voltage amplitude. With the increase in air gap thickness, the rising rate of heat sources will also increase. However, when the voltage is 10 kV, the heat source increases first and then decreases with the increase in the air gap thickness. The discharge does not occur when the air gap thickness reaches above 4 mm. This study provides theoretical support for identifying the deterioration degree of air gap defects from the view of temperature.

10 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XLXingming Long
Xingming Long
XLXingming Long
Xingming Long
JZJing Zhou
Jing Zhou
Augmented reality (AR) applied in education provides learners a possible way for better understanding and thorough learning. Although the traditional projector is used to integrate the augmented information with real objects without wearing AR glasses, the projector-based AR system is unlikely to be adopted widely in education due to the cost, heavy weight, and space issues. In this paper, an alternative projector-camera AR platform, utilizing a digital light processing (DLP) module matched with a Beaglebone Black (BB) controller, is proposed for AR physical experiments. After describing the DLP-based AR learning design method, the algorithm of pre-deforming projection content with simulation-based poly fitting is presented to keep the virtual asset consistent with the user action; and then a prototype with the content regarding the thermal management of power devices is illustrated to validate the performance of the AR experimental platform. The result shows that the DLP-based AR platform is an accurate and interactive AR system with a response time of 1 s, and a registration deviation of 3 mm. It is also an affordable AR learning design tool with a bill of materials of about $200, and thus casts light on creating AR-based physical experiments to explore more physical phenomena.

25 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YJYuan JIANG
Yuan JIANG
JZJing Zhou
Jing Zhou
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
Yihua DanYihua Dan
Yihua Dan
WHWu Hao
Wu Hao
During the long-term operation of the DC grounding electrode of the converter station, there are often hazards such as heating and aging of the coke layer, and burning and corrosion at the connection between the feed rod and the cable, resulting in break problems at the connection between the cable and the feed rod. Currently, the operational status monitoring of grounding electrodes primarily relies on daily tracking of well temperature, humidity, and water level characteristics; periodic testing; and on-site excavation. However, the above methods cannot accurately obtain the breakage location information at the connection between the cable and the feed rod. To address these issues, this paper first analyzes the current distribution law in the feeder rod of the DC grounding electrode. Subsequently, it studies the impact of localized fractures in the DC grounding electrode on the surface potential distribution characteristics. Finally, an Operation State Detection Method (OSDM) based on potential distribution is proposed and validated through case studies, demonstrating high measurement accuracy. The results indicate that OSDM can effectively monitor the operational status of DC grounding electrodes, providing a reference for their maintenance and repair.

12 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DLDingyuan Li
Dingyuan Li
JZJing Zhou
Jing Zhou
Zhanlong ZhangZhanlong Zhang
Zhanlong Zhang
YYYu Yang
Yu Yang
ZDZijian Dong
Zijian Dong
ZPZhicheng Pan
Zhicheng Pan
The residual magnetism of the iron core of power transformers can cause an excitation inrush current, posing a threat to the safe and stable operation of the power grid. This paper proposes a transformer remanence measurement method based on a demagnetization hysteresis loop to address the problems of large errors, complex operation, and poor universality in existing remanence measurement methods. This method is designed for off-grid transformers to avoid potential interference to the power grid caused by current pulses during the measurement process. This method constructs an RLC oscillation circuit that utilizes capacitor energy storage and iron core magnetic field energy conversion, combined with the dynamic characteristics of hysteresis loops, to achieve accurate measurement of residual magnetism and synchronous demagnetization. The effectiveness of this method has been verified through residual magnetism measurement experiments on ring transformers and large converter transformers, and it can be applied in specific engineering practice operations. Theoretical analysis shows that the charging range of energy storage capacitors is affected by the hysteresis characteristics of the iron core and the saturation magnetic flux, and the residual magnetization value can be directly calculated based on the difference in the intersection point of the longitudinal axis of the demagnetization hysteresis loop. Simulation and experimental results show that the measurement error of the proposed method is less than 5%—significantly better than traditional methods. This method does not require complex control strategies, has high precision and efficiency, and can provide reliable technical support for residual magnetism detection and suppression of off-grid power transformers.

6 November 2020 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
JZJing Zhou
Jing Zhou
HCHongjun Chen
Hongjun Chen
YWYang Wang
Yang Wang
XLXingming Long
Xingming Long
Strain is one of the important factors affecting the two-dimensional electron gas (2DEG) transform in AlGaN/GaN material based high electron mobility transistors (HEMTs) by polarization effects. In this paper, the effects of inhomogeneous biaxial strain in different regions of the AlGaN barrier layer on electrical properties of normally-off HEMTs with p-GaN gate were discussed. The results show that biaxial strain applied in three regions has different influence on transfer, output and breakdown characteristics of the device. The strain applied in region under gate has the most significant impact on threshold voltage and drain saturation current with a decreasing of 39% and an increasing of 97% respectively as the strained lattice constant increases from 3.173061Å to 3.187229Å.While, strain applied between gate and drain electrode can improve the off-state breakdown voltage by 12% with the increasing of strained lattice constant.