This work provides new insights into the dynamics of silica nanoparticle-based removal of organic fluids (here oil) from naturally occurring porous media. We have used 4D (time-resolved 3D) imaging at pore-scale using X-ray computed micro-tomography (μCT) technique. The captured 3D tomographic time-series data reveal the dynamics of immiscible oil displacement from a carbonate rock upon injection of nanoparticle (NP) suspensions (0.06 and 0.12 wt% SiO2in deionised water). Our analysis shows significant pore-scale remobilisation of initially trapped oil upon injection of the NP suspensions, specifically, at higher concentration. Our data shows that oil clusters become significantly smaller with larger fluid/fluid interface as a result of the higher concentration NP injection. This paper demonstrates that use of 2D radiograms collected during fluid injections allows monitoring flow dynamics at time resolutions down to a few seconds using conventional laboratory-based μCT scanners. Here, as an underlying mechanism for oil remobilisation, we present the first 4D evidence ofin-situformation of an oil in water emulsion induced by nanoparticles.
This study reveals the pore-scale details of oil mobilisation and recovery from a carbonate rock upon injection of aqueous nanoparticle (NP) suspensions. X-ray computed micro-tomography (μCT), which is a non-destructive imaging technique, was used to acquire a dataset which includes: (i) 3D images of the sample collected at the end of fluid injection steps, and (ii) 2D radiogram series collected during fluid injections. The latter allows monitoring fluid flow dynamics at time resolutions down to a few seconds using a laboratory-based μCT scanner. By making this dataset publicly available we enable (i) new image reconstruction algorithms to be tested on large images, (ii) further development of image segmentation algorithms based on machine learning, and (iii) new models for multi-phase fluid displacements in porous media to be evaluated using images of a dynamic process in a naturally occurring and complex material. This dataset is comprehensive in that it offers a series of images that were captured before/during/and after the immiscible fluid injections.
Complex pore structures with multiple inclusions challenge the predictive accuracy of rock physics models. This study introduces a novel method for estimating a single equivalent pore aspect ratio that optimizes rock physics model predictions by minimizing discrepancies with experimental measurements in porous rocks with multiple inclusions with variable aspect ratios and proportions. The proposed methodology uses digital rock physics numerical simulations for validation. A comparative analysis is conducted between the equivalent aspect ratio derived from optimized rock physics models, numerical simulations, and the aspect ratio distribution estimated from digital rock samples. The approach is tested on both synthetic and real core samples, demonstrating its robustness and applicability to field data, including core samples and well log data. The validation results confirm that the method enhances predictive accuracy and offers a versatile framework for addressing pore complexity in subsurface rock formations.
In order to support bone tissue regeneration, porous biomaterial implants (scaffolds) must offer chemical and mechanical properties, besides favorable fluid transport. Titanium implants provide these requirements, and depending on their microstructural parameters, the osteointegration process can be stimulated. The pore structure of scaffolds plays an essential role in this process, guiding fluid transport for neo-bone regeneration. The objective of this work was to analyze geometric and morphologic parameters of the porous microstructure of implants and analyze their influences in the bone regeneration process, and then discuss which parameters are the most fundamental. Bone ingrowths into two different sorts of porous titanium implants were analyzed after 7, 14, 21, 28, and 35 incubation days in experimental animal models. Measurements were accomplished with x-ray microtomography image analysis from rabbit tibiae, applying a pore-network technique. Taking into account the most favorable pore sizes for neo-bone regeneration, a novel approach was employed to assess the influence of the pore structure on this process: the analyses were carried out considering minimum pore and connection sizes. With this technique, pores and connections were analyzed separately and the influence of connectivity was deeply evaluated. This investigation showed a considerable influence of the size of connections on the permeability parameter and consequently on the neo-bone regeneration. The results indicate that the processing of porous scaffolds must be focused on deliver pore connections that stimulate the transport of fluids throughout the implant to be applied as a bone replacer.
1 April 2021 in Journal of South American Earth Sciences