Aims Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1–2% of the cases. However, follow‐up data about this condition are scarcely available in the literature. This study aimed to report the long‐term outcomes and clinical management following LVAD explantation. Methods and results An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre‐implant characteristics were retrieved and compared with the non‐recovery patients. The follow‐up data after explantation were collected via a questionnaire. A Kaplan–Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow‐up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter‐quartile range: 29–52), and 23 (82%) were male. Baseline left ventricular ejection fraction was 18% (inter‐quartile range: 10–20%), and 60.7% of the patients had Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2. Aetiologies of HF were dilated cardiomyopathy in 36%, myocarditis in 32%, and ischaemic in 14% of the patients, and 18% had miscellaneous aetiologies. The devices implanted were HeartMate II in 14 (50%), HVAD in 11 (39%), HeartMate 3 in 2 (7%), and 1 unknown with a median duration of support of 410 days (range: 59–1286). The median follow‐up after explantation was 26 months (range 0.3–73 months), and 82% of the patients were in New York Heart Association Class I or II. Beta‐blockers were prescribed to 85%, angiotensin‐converting enzyme inhibitors to 71%, and loop diuretics to 50% of the patients, respectively. Freedom from the composite endpoint was 100% after 30 days and 88% after 2 years. Conclusions The survival after LVAD explantation is excellent without the need for heart transplantation or LVAD reimplantation. Only a minority of the patients suffer from a relapse of significant HF.
In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. Procedures in adult patients (January 2011–June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011–2013, 2014–2017 and 2018–2020). Adverse event rates (AERs) were calculated and stratified into early phase (3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3–2.6) years. The annual number of implants (range: 346–600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4–7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.
10 October 2020 in European Journal of Cardio-Thoracic Surgery
Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation. The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06–1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progressively without intervention after an LVAD implant. Therefore, these data suggest that patient selection for concomitant tricuspid valve surgery should not be based solely on TR grade.
Acute aortic dissection (AAD) is a rare condition, but together with acute myocardial infarction (AMI) and pulmonary embolism (PE) it belongs to the most relevant and life-threatening causes of acute chest pain. Until now, there has been no specific blood test in the diagnostic workup of AAD. To identify clinically relevant biomarkers for AAD, we applied Proseek® Multiplex assays to plasma samples from patients with AAD, AMI, PE, thoracic aortic aneurysm (TAA), and non-cardiovascular chest pain (nonCVD). Subsequently, we validated top hits using conventional immunoassays and examined their expression in the aortic tissue. Interleukin 10 (IL-10) alone showed the best performance with a sensitivity of 55% and a specificity of 98% for AAD diagnosis. The combination of D-dimers, high-sensitive troponin T (hs-TnT), interleukin 6 (IL-6), and plasminogen activator inhibitor 1 (PAI1) correctly classified 75% of AAD cases, delivering a sensitivity of 83% and specificity of 95% for its diagnosis. Moreover, this model provided the correct classification of 77% of all analyzed cases. Our data suggest that IL-10 shows potential to be a rule-in biomarker for AAD. Moreover, the addition of PAI1 and IL-6 to hs-TnT and D-dimers may improve the discrimination of suspected AAD, AMI, and PE in patients presenting with acute chest pain.