Ayla Thijssen

Ms. Ayla Thijssen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
ATAyla Thijssen
Ayla Thijssen
RSRamon-Michel R Schreuder
Ramon-Michel R Schreuder
RFRoger Fonollà
Roger Fonollà
QZQuirine van der Zander
Quirine van der Zander
TSThom Scheeve
Thom Scheeve
ESErik Schoon
Erik Schoon
Computer-aided diagnosis systems (CADx) can improve colorectal polyp (CRP) optical diagnosis. For integration into clinical practice, better understanding of artificial intelligence (AI) by endoscopists is needed. We aimed to develop an explainable AI CADx capable of automatically generating textual descriptions of CRPs. For training and testing of this CADx, textual descriptions of CRP size and features according to the Blue Light Imaging (BLI) Adenoma Serrated International Classification (BASIC) were used, describing CRP surface, pit pattern, and vessels. CADx was tested using BLI images of 55 CRPs. Reference descriptions with agreement by at least five out of six expert endoscopists were used as gold standard. CADx performance was analyzed by calculating agreement between the CADx generated descriptions and reference descriptions. CADx development for automatic textual description of CRP features succeeded. Gwet’s AC1 values comparing the reference and generated descriptions per CRP feature were: size 0.496, surface-mucus 0.930, surface-regularity 0.926, surface-depression 0.940, pits-features 0.921, pits-type 0.957, pits-distribution 0.167, and vessels 0.778. CADx performance differed per CRP feature and was particularly high for surface descriptors while size and pits-distribution description need improvement. Explainable AI can help comprehend reasoning behind CADx diagnoses and therefore facilitate integration into clinical practice and increase trust in AI.

26 August 2024 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
ATAyla Thijssen
Ayla Thijssen
RSRamon-Michel Schreuder
Ramon-Michel Schreuder
NDNikoo Dehghani
Nikoo Dehghani
MSMarieke Schor
Marieke Schor
PWPeter H.N. de With
Peter H.N. de With
ESErik J. Schoon
Erik J. Schoon
Background and study aims Artificial intelligence (AI) has great potential to improve endoscopic recognition of early stage colorectal carcinoma (CRC). This scoping review aimed to summarize current evidence on this topic, provide an overview of the methodologies currently used, and guide future research. Methods A systematic search was performed following the PRISMA-Scr guideline. PubMed (including Medline), Scopus, Embase, IEEE Xplore, and ACM Digital Library were searched up to January 2024. Studies were eligible for inclusion when using AI for distinguishing CRC from colorectal polyps on endoscopic imaging, using histopathology as gold standard, reporting sensitivity, specificity, or accuracy as outcomes. Results Of 5024 screened articles, 26 were included. Computer-aided diagnosis (CADx) system classification categories ranged from two categories, such as lesions suitable or unsuitable for endoscopic resection, to five categories, such as hyperplastic polyp, sessile serrated lesion, adenoma, cancer, and other. The number of images used in testing databases varied from 69 to 84,585. Diagnostic performances were divergent, with sensitivities varying from 55.0% to 99.2%, specificities from 67.5% to 100% and accuracies from 74.4% to 94.4%. Conclusions This review highlights that using AI to improve endoscopic recognition of early stage CRC is an upcoming research field. We introduced a suggestions list of essential subjects to report in research regarding the development of endoscopy CADx systems, aiming to facilitate more complete reporting and better comparability between studies. There is a knowledge gap regarding real-time CADx system performance during multicenter external validation. Future research should focus on development of CADx systems that can differentiate CRC from premalignant lesions, while providing an indication of invasion depth.

10 May 2025 in Cancers
Verified
Journal Article
Open access
PDF file
ATAyla Thijssen
Ayla Thijssen
NDNikoo Dehghani
Nikoo Dehghani
RSRuud Schrauwen
Ruud Schrauwen
EKEric Keulen
Eric Keulen
EREveline J. A. Rondagh
Eveline J. A. Rondagh
ESErik J. Schoon
Erik J. Schoon
Background/Objectives: Artificial intelligence (AI) algorithms for diagnosing colorectal polyps are emerging but not yet widely used. Trust in AI is lacking and could be improved by visually explainable AI, such as heatmaps. This study aims to investigate the association between heatmap position and AI accuracy for the endoscopic characterization of colorectal polyps. Methods: Four AI algorithms diagnosed 2133 prospectively collected images of 376 colorectal polyps from two hospitals, using histopathology as the gold standard. Heatmap position was compared to the human-annotated polyp position. Generalized estimating equations were used to assess the association between heatmap position and a correct AI diagnosis. Results: Higher percentages of heatmap covering the colorectal polyp were associated with correct diagnoses in all four algorithms (OR 1.013 [95% CI 1.006–1.019], OR 1.025 [95% CI 1.011–1.039], OR 1.038 [95% CI 1.024–1.053], and OR 1.039 [95% CI 1.020–1.058]—all p < 0.001). A higher percentage of polyp not covered by heatmap was associated with a correct diagnosis of Algorithm 1 (OR 1.006 [95% CI 1.003–1.010], p < 0.001), while in Algorithm 2, a lower percentage was associated with a correct diagnosis (OR 0.992 [95% CI 0.985–1.000], p 0.044). Algorithms 3 and 4 showed negative, but not statistically significant, associations. Conclusions: Higher percentages of heatmap covering the polyp were associated with correct diagnoses of four AI algorithms. This indicates that it is clinically relevant to strive for AI predictions with heatmaps covering as much colorectal polyp tissue as possible. Knowing how to interpret heatmaps could increase trust in AI and, with that, benefit the implementation of AI in clinical practice.

9 May 2023 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
ATAyla Thijssen
Ayla Thijssen
RSRamon-Michel Schreuder
Ramon-Michel Schreuder
RFRoger Fonollà
Roger Fonollà
QZQuirine van der Zander
Quirine van der Zander
TSThom Scheeve
Thom Scheeve
ESErik Schoon
Erik Schoon
Article published online: 09 June 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

16 February 2026 in Techniques and Innovations in Gastrointestinal Endoscopy
Verified
Journal Article
Open access
ATAyla Thijssen
Ayla Thijssen
NDNikoo Dehghani
Nikoo Dehghani
RSRamon-Michel Schreuder
Ramon-Michel Schreuder
JBJurjen J. Boonstra
Jurjen J. Boonstra
EDEvelien Dekker
Evelien Dekker
ESErik J. Schoon
Erik J. Schoon

9 July 2026 in Endoscopy
Verified
Journal Article
Open access
ATAyla Thijssen
Ayla Thijssen
RSRamon-Michel Schreuder
Ramon-Michel Schreuder
NDNikoo Dehghani
Nikoo Dehghani
EDEvelien Dekker
Evelien Dekker
JBJurjen J. Boonstra
Jurjen J. Boonstra
ESErik J. Schoon
Erik J. Schoon
Background Suboptimal human–artificial intelligence (AI) interaction is a potential roadblock for implementation of AI in clinical practice. We aimed to evaluate the interaction between AI and endoscopists in the optical diagnosis of colorectal carcinoma (CRC). Methods International endoscopists were invited to diagnose colorectal lesions online. After a pretest of 15 videos, the diagnosis could be adjusted in the subsequent 35 videos after receiving a simulated AI diagnosis. Histology was the gold standard. Endoscopists’ diagnoses before and after AI were compared using the signal detection theory. Inappropriate response to AI was defined as decreased diagnostic performance by the endoscopist after AI. Results In 2730 diagnoses, the 78 participating endoscopists reached diagnostic accuracies of 71.4 % before and 73.7 % after AI (P < 0.001). Before AI, endoscopists missed only a few true CRCs (mean hit rate 0.86), at the cost of a mean false alarm rate of 0.35. Inappropriate response to AI was observed in 28.2 % of endoscopists. After AI, most endoscopists (41.0 %) shifted toward a more conservative attitude, tending to diagnose a lesion as non-CRC. Conclusions Inappropriate response to AI is an issue in human–AI interaction for the optical diagnosis of CRC. Before using AI, endoscopists should become familiar with their own optical diagnostic performance, and that of the AI system, to possibly improve interaction.