Metasurfaces enable magnetic resonance imaging (MRI) without cables inside the bore by locally improving the sensitivity of scanner-integrated receive coils. This study systematically evaluates a novel grid design to provide signal enhancement for patient imaging. The potential of the proposed metasurface grid design was analyzed regarding its unit cell density and compared with stripe type metasurfaces. The effects were examined in-depth by numerical simulation, workbench measurements, and MRI experiments at 3 Tesla. Differences in the signal-to-noise ratio (SNR) using either the integrated body or spine coils were evaluated, as well as the influence of the metasurface orientation. The grid design provided a favorable eigenmode usable for MR imaging, where it has shown significantly less dependence on orientation, compared to stripe metasurfaces. With the densest grid, more than 26% higher SNR than its most spaced design was achieved. Combining the metasurface for imaging with the spine coil proved to be superior to the body coil. Applying the metasurface for knee imaging, the SNR was locally enhanced by more than 10-fold compared to the scan with only the spine coil. The high-density grid metasurfaces provided benefits compared to the multitude of designs evaluated. This work provides a comprehensive foundation for future developments of metasurfaces for MRI, whose advantages may be exploited e.g. in the domain of interventional radiology.
1 April 2025 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Metasurfaces have proved valuable in magnetic resonance imaging (MRI) applications through modifying the field profiles of radiofrequency coils to enhance imaging. Using metasurfaces to enhance a conventional coil, such as the table-integrated spine coil, allows imaging with practically no cables inside the bore. This work investigated the fundamental relationship between an MRI system's field strength and the enhancement effect of a metasurface. We simulated and manufactured grid metasurfaces for field strengths of 0.55 Tesla (0.55 T), 1.5 T and 3 T and evaluated them experimentally. We found increased enhancements of the signal-to-noise ratio (SNR) with lower field strengths. At 0.55 T, the enhancement in the vicinity of the metasurface (10.9-fold) was measured 3.8 times higher than at 3 T. Moreover, the SNR decreased less with field strength next to the metasurface compared to the spine coil. Our results indicate the capability of metasurfaces in low field MRI systems and can stimulate further research. This could benefit future applications in MRI-guided interventions through simplified handling, as well as countries currently underserved with MRIs due to low manufacturing costs.
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. This study proposes a standardized methodology to improve reproducibility and consistency across research sites (testers) and simulation tools (testing conditions). The methodology includes detailed simulation workflow and performance metrics for RF Tx elements. The impact of the used mesh setting is assessed. Following the methodology, a reproducibility study was conducted using CST Microwave Studio Suite, HFSS, and Sim4Life. The methodology and simulations were ultimately validated through 7 T MRI phantom experiments. The reproducibility study showed consistent performance with less than 6% standard deviation for B1+ fields and 12% for peak SAR averaged over 10 g tissue (pSAR10g). The SAR efficiency metric (|B1+|/√pSAR10g) was particularly robust (<5%). The simulated and experimental |B1+| maps showed good qualitative agreement. This study demonstrates the feasibility of a standardized methodology for achieving reproducible RF Tx element electromagnetic field simulations. By following the FAIR principles including making the framework publicly available, we promote transparency and collaboration within the MRI community, supporting the advancement of technological innovation and improving patient safety in UHF-MRI.
1 November 2021 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Irreversible electroporation (IRE) is a non-thermal tumor ablation method where strong electrical fields between at least two electrodes are used and can be seen as an alternative to thermal ablation techniques. The therapy outcome directly dependents on the position of the electrodes. Real-time monitoring of the IRE by magnetic resonance imaging (MRI) would allow to detect unwanted electrode displacement and to apply visualization methods for the ablation area. This requires that the IRE generator does not significantly interfere with the MRI. Currently, there is no IRE generator available designed for MRI-guided IRE.This paper presents an IRE system specifically developed for use in an MRI environment. The system is initially tested with a standard IRE sequence and then the interference between a clinical 3 T MRI device and the IRE system is investigated using a noise measurement and the signal-to-noise ratio (SNR) of images acquired with a gradient echo (GRE) sequence. The results show, that although the SNR of the images decrease by maximal 36 % when the IRE system is switched on, image quality does not visibly degrade. Hence, MRI-guided IRE is feasible with the proposed system.Clinical relevance— This paper demonstrates the possibility of MRI-guided IRE with only minor image degradation when the IRE system is used in parallel with MRI imaging.
Many different transmit (Tx) coil concepts and designs for 7‐T magnetic resonance imaging of the head have been proposed. Most of them are placed close to the head and in combination with the receive coils creating a helmet‐like structure. This limits the space for additional equipment for external stimuli. A large diameter transmit coil can increase the ease using supplementary measurement devices. Therefore, this study systematically evaluated nine different Tx elements regarding their performance within a large diameter transmit coil with a diameter 350 mm. Each Tx element was examined regarding its power and specific absorption rate (SAR) efficiencies, its loading dependence, intrinsic decoupling, and its radio frequency (RF) shimming capability. Additionally, an experimental validation of ‐maps was performed. The loop‐based Tx elements (circular and rectangular loop) provided the highest power and SAR efficiency with at least 15.5% and 21.2% higher efficiencies for a single channel and 22.1% and 18.0% for the eight‐channel array, respectively. In terms of voxel‐wise power efficiency, the circular loop was the superior Tx element type within most of the head. Looking at the voxel‐wise SAR efficiency, the loop‐based elements manifest themselves as the most efficient type within most of the central brain. The mutual coupling was lowest for the passively fed dipole ( 31.23 dB). The highest RF shimming capability in terms of sum of normalized singular values was calculated for the rectangular (4.21) and the circular loop (4.36), whereby the L‐curve results showed that the arrays have only minor shimming performance differences for the transversal slice. For the hippocampus, the meander element provided the highest overall homogeneity with a minimal coefficient of variation (CoV) of 5.1%. This work provides extensive and unique data for single and eight‐channel Tx elements applying common performance benchmarks and enables further discourse on multi‐channel evaluations towards large diameter Tx coils at 7‐T head imaging. On the bases of the provided results, the preferable Tx element type for this specific application is loop‐based.
1 January 2026 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology