BIlguun Nurzed

Mr. BIlguun Nurzed

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BNBIlguun Nurzed
BIlguun Nurzed
Nandita SahaNandita Saha
Nandita Saha
JMJason Millward
Jason Millward
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
The literature reports highlight the transmission field (B1+) uniformity and efficiency constraints of cardiac magnetic resonance imaging (MRI) at ultrahigh magnetic fields (UHF). This simulation study proposes a 3D Metamaterial (MM) to address these challenges. The study proposes a 3D MM consisting of unit cells (UC) with split ring resonator (SRR) layers immersed in dielectric material glycerol. Implementing the proposed MM design aims to reduce the effective thickness and weight of the dielectric material while shaping B1+ and improving the penetration depth. The latter is dictated by the chosen array size, where small local UC arrays can focus B1+ and larger UC arrays can increase the field of view, at the cost of a lower penetration depth. Designing RF antennas that can effectively transmit at 21.0 T while maintaining patient safety and comfort is challenging. Using Self-Grounded Bow-Tie (SGBT) antennas in conjunction with the proposed MM demonstrated enhanced B1+ efficiency and uniformity across the human heart without signal voids. The study employed dynamic parallel transmission with tailored kT points to homogenize the 3D flip angle over the whole heart. This proof-of-concept study provides the technical foundation for human cardiac MRI at 21.0 T. Such numerical simulations are mandatory precursors for the realization of whole-body human UHF MR instruments.

15 March 2023 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
BNBIlguun Nurzed
BIlguun Nurzed
Andre KuehneAndre Kuehne
Andre Kuehne
CAChristoph Stefan Aigner
Christoph Stefan Aigner
SSSebastian Schmitter
Sebastian Schmitter
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
TEThomas Wilhelm Eigentler
Thomas Wilhelm Eigentler
Objective: To examine the feasibility of human cardiac MR (CMR) at 14.0 T using high-density radiofrequency (RF) dipole transceiver arrays in conjunction with static and dynamic parallel transmission (pTx). Materials and methods: RF arrays comprised of self-grounded bow-tie (SGBT) antennas, bow-tie (BT) antennas, or fractionated dipole (FD) antennas were used in this simulation study. Static and dynamic pTx were applied to enhance transmission field (B1+) uniformity and efficiency in the heart of the human voxel model. B1+ distribution and maximum specific absorption rate averaged over 10 g tissue (SAR10g) were examined at 7.0 T and 14.0 T. Results: At 14.0 T static pTx revealed a minimum B1+ROI efficiency of 0.91 μT/√kW (SGBT), 0.73 μT/√kW (BT), and 0.56 μT/√kW (FD) and maximum SAR10g of 4.24 W/kg, 1.45 W/kg, and 2.04 W/kg. Dynamic pTx with 8 kT points indicate a balance between B1+ROI homogeneity (coefficient of variation < 14%) and efficiency (minimum B1+ROI > 1.11 µT/√kW) at 14.0 T with a maximum SAR10g < 5.25 W/kg. Discussion: MRI of the human heart at 14.0 T is feasible from an electrodynamic and theoretical standpoint, provided that multi-channel high-density antennas are arranged accordingly. These findings provide a technical foundation for further explorations into CMR at 14.0 T.

2 February 2026 in Advanced Materials
Verified
Journal Article
Open access
Nandita SahaNandita Saha
Nandita Saha
BNBIlguun Nurzed
BIlguun Nurzed
MBMostafa Berangi
Mostafa Berangi
Andre KuehneAndre Kuehne
Andre Kuehne
HWHelmar Waiczies
Helmar Waiczies
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
A metamaterial‐integrated radio frequency antenna (MTMA), implemented in planar and bend configurations, enables high‐resolution MRI of the eye, orbit, and occipital brain at 7.0 T. Its dual‐layer co‐planar architecture integrates a two‐channel transceive loop with a metamaterial layer composed of subwavelength epsilon‐negative unit cells. These unit cells were custom‐designed based on classical split‐ring resonators for operation at 7.0 T. Electromagnetic simulations, including human voxel models, guided the design and characterization of the MTMA's electromagnetic behavior. Both MTMA configurations were benchmarked against conventional loop coil arrays in phantoms and in vivo for experimental validation, demonstrating enhanced transmit (B 1 + ) efficiency and receive sensitivity enabled by the metamaterial layer through resonant near‐field coupling. MRI safety was verified through SAR simulations, bio‐thermal modeling, Magnetic Resonance thermometry, and fiber‐optic sensors, confirming compliance with safety guidelines. The Bend‐MTMA enabled in vivo human MRI of the eye and orbit in healthy volunteers, including B 1 + mapping, and provided diagnostic T 1 ‐ and T 2 ‐weighted imaging in volunteers with retinal pathology and sinus cysts, demonstrating clinical applicability. The Planar‐MTMA enabled occipital lobe MRI in human volunteers, achieving superior signal coverage and transmit performance. The modular unit cell design enables tuning across MRI magnetic field strengths, establishing a clinically translatable metamaterial‐integrated antenna platform for ocular and neurological imaging.

17 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MHMax Joris Hubmann
Max Joris Hubmann
BNBIlguun Nurzed
BIlguun Nurzed
SHSam-Luca J.D. Hansen
Sam-Luca J.D. Hansen
RKRobert Kowal
Robert Kowal
NSNatalie Schön
Natalie Schön
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. This study proposes a standardized methodology to improve reproducibility and consistency across research sites (testers) and simulation tools (testing conditions). The methodology includes detailed simulation workflow and performance metrics for RF Tx elements. The impact of the used mesh setting is assessed. Following the methodology, a reproducibility study was conducted using CST Microwave Studio Suite, HFSS, and Sim4Life. The methodology and simulations were ultimately validated through 7 T MRI phantom experiments. The reproducibility study showed consistent performance with less than 6% standard deviation for B1+ fields and 12% for peak SAR averaged over 10 g tissue (pSAR10g). The SAR efficiency metric (|B1+|/√pSAR10g) was particularly robust (<5%). The simulated and experimental |B1+| maps showed good qualitative agreement. This study demonstrates the feasibility of a standardized methodology for achieving reproducible RF Tx element electromagnetic field simulations. By following the FAIR principles including making the framework publicly available, we promote transparency and collaboration within the MRI community, supporting the advancement of technological innovation and improving patient safety in UHF-MRI.

19 July 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Faezeh RahimiFaezeh Rahimi
Faezeh Rahimi
BNBIlguun Nurzed
BIlguun Nurzed
TEThomas W. Eigentler
Thomas W. Eigentler
MBMostafa Berangi
Mostafa Berangi
EOEva Oberacker
Eva Oberacker
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
Thermal Magnetic Resonance (ThermalMR) integrates Magnetic Resonance Imaging (MRI) diagnostics and targeted radio-frequency (RF) heating in a single theranostic device. The requirements for MRI (magnetic field) and targeted RF heating (electric field) govern the design of ThermalMR applicators. We hypothesize that helmet RF applicators (HPA) improve the efficacy of ThermalMR of brain tumors versus an annular phased RF array (APA). An HPA was designed using eight broadband self-grounded bow-tie (SGBT) antennae plus two SGBTs placed on top of the head. An APA of 10 equally spaced SGBTs was used as a reference. Electromagnetic field (EMF) simulations were performed for a test object (phantom) and a human head model. For a clinical scenario, the head model was modified with a tumor volume obtained from a patient with glioblastoma multiforme. To assess performance, we introduced multi-target evaluation (MTE) to ensure whole-brain slice accessibility. We implemented time multiplexed vector field shaping to optimize RF excitation. Our EMF and temperature simulations demonstrate that the HPA improves performance criteria critical to MRI and enhances targeted RF and temperature focusing versus the APA. Our findings are a foundation for the experimental implementation and application of a HPA en route to ThermalMR of brain tumors.