Malek Bibani

Malek Bibani


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2019 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
HEHouda Essousi
Houda Essousi
HBHoucine Barhoumi
Houcine Barhoumi
MBMalek Bibani
Malek Bibani
NKNadia Ktari
Nadia Ktari
FWFrank Wendler
Frank Wendler
OKOlfa Kanoun
Olfa Kanoun
This study reports a new chemical sensor based on ion-imprinted polymer matrix using copper nanoparticles-polyaniline nanocomposite (IIP-Cu-NPs/PANI). This sensor was prepared by electropolymerization using aniline as a functional monomer and nitrate as template onto the copper nanoparticles-modified glassy carbon (GC) electrode surface. Both ion-imprinted (IIP) and nonimprinted (NIP) electrochemical sensor surfaces were evaluated using UV-Visible spectrometry and scanning electron microscopy (SEM). The electrochemical analysis was made via cyclic voltammetry (CV), linear sweep voltammetry (LSV), and impedance spectroscopy (IS). Throughout this study various analytical parameters, such as scan rate, pH value, concentration of monomer and template, and electropolymerization cycles, were optimized. Under the optimum conditions, the peaks current of nitrate was linear to its concentration in the range of 1μM-0.1M with a detection limit of 31μM and 5μM by EIS and LSV. The developed imprinted nitrate sensor was successfully applied for nitrate determination in different real water samples with acceptable recovery rates.

17 December 2014 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
LOLaurence Ourry
Laurence Ourry
SMSofia Marchesini
Sofia Marchesini
MBMalek Bibani
Malek Bibani
SMSilvana Mercone
Silvana Mercone
SASouad Ammar
Souad Ammar
Fayna MammeriFayna Mammeri
Fayna Mammeri

4 June 2019 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
MBMalek Bibani
Malek Bibani
RBRomain Breitwieser
Romain Breitwieser
AAAlex Aubert
Alex Aubert
VLVincent Loyau
Vincent Loyau
SMSilvana Mercone
Silvana Mercone
Fayna MammeriFayna Mammeri
Fayna Mammeri
Background: In extrinsically magnetoelectric materials made of two components, the direct magnetoelectric coupling arises from a mechanical strain transmission at the interface due to the shape change of the magnetostrictive component under an external magnetic field. Here, the size of the interface between the two components plays a crucial role. Therefore, the development of nanomaterials exhibiting large surface-to-volume ratios can help to respond to such a requirement. However, the magnetic nanoparticles (NPs) must be highly magnetostrictive and magnetically blocked at room temperature despite their nanometer-size. We describe here the use of the polyol process to synthesize cobalt ferrite (CoxFe3−xO4) nanoparticles with controlled size and composition and the study of the relationship between size and composition and the magnetic behavior.Methods: We used an improved synthesis of magnetostrictive CoxFe3−xO4 NPs based on the forced hydrolysis of metallic salts in a polyol solvent, varying the fraction x. Stoichiometric NPs (x = 1) are expected to be highly magnetostrictive while the sub-stoichiometric NPs (particularly for x ≈ 0.7) are expected to be less magnetostrictive but to present a higher magnetocrystalline anisotropy constant, as previously observed in bulk cobalt ferrites. To control the size of the NPs, in order to overcome the superparamagnetic limit, as well as their chemical composition, in order to get the desired magnetomechanic properties, we carried out the reactions for two nominal precursor contents (x = 1 and 0.67), using two different solvents, i.e., triethylene glycol (TriEG) and tetraethylene glycol (TetEG), and three different durations of refluxing (3, 6 and 15 h). The structure, microstructure and composition of the resulting NPs were then investigated by using X-ray diffraction (XRD), transmission electron microscopy (TEM) and X-ray fluorescence spectroscopy (XRF), respectively. The magnetic properties were also evaluated using standard magnetometry. To measure the magnetostrictive response of the particles, the particles were sintered to dense pellets on which strain gauges were bonded, measuring the size variation radially, as a function of a dc magnetic field.Findings: We found two samples, the first one being stoichiometric and magnetostrictive, and the second one being sub-stoichiometric and presenting a higher magnetization, that are appropriate to be used as ferromagnetic building blocks in nanostructured magnetoelectric materials, particularly materials based on polymers. We show that the polyol solvent and the reaction time are two key parameters to control the size and the magnetic properties of the resulting nanoparticles. We believe that these results provide relevant insights to the design of efficient magnetic and magnetostrictive nanoparticles that can be further functionalized by coupling agents, to be contacted with piezoelectric polymers.

25 January 2025 in Microchimica Acta
Verified
Journal Article
Open access
PDF file
MBMalek Bibani
Malek Bibani
MCMagdolna Casian
Magdolna Casian
Bogdan FeierBogdan Feier
Bogdan Feier
Diana Speranța BogdanDiana Speranța Bogdan
Diana Speranța Bogdan
Oana HosuOana Hosu
Oana Hosu
Cecilia CristeaCecilia Cristea
Cecilia Cristea
A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites. The developed disposable aptasensor allowed label-free detection of VAN via electrochemical impedance spectroscopy (EIS) across a wide range of concentrations (50–1000 nM), with a limit of detection (LOD) of 1.721 nM. The aptasensor presented good selectivity against some commonly found interferences in human serum and milk and was successfully applied to the analysis of these samples. Graphical Abstract

20 November 2020 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
MBMalek Bibani
Malek Bibani
NKNadia Ktari
Nadia Ktari
NFNajla Fourati
Najla Fourati
CZChouki Zerrouki
Chouki Zerrouki
RKRafik KALFAT
Rafik KALFAT

7 February 2024 in Iranian Journal of Science
Verified
Journal Article
Closed access
PDF file
ANAmira Nahdi
Amira Nahdi
MBMalek Bibani
Malek Bibani
FTFathi Touati
Fathi Touati
HDHassouna Dhaouadi
Hassouna Dhaouadi