The accuracy of static guided implant surgery (sGIS) using conventional planning workflow has been extensively examined; however, more information is required to justify the application of fully digital planning protocol. The purpose of this study was to investigate the clinical accuracy of sGIS with a fully digital planning workflow. Twenty-one partially edentulous patients were enrolled in this prospective study. Cone-beam computed tomography (CBCT) and intraoral scans were taken and superimposed by matching the dental surface images directly (surface registration protocol) or by matching fiducial markers on a stereolithographic (SLA) radiographic template fabricated from the digital data of the intraoral scan (fiducial marker registration protocol). Virtual implant treatment plans were then determined, and tooth-supported SLA surgical guides were fabricated according to the plans. Twenty-six implant surgeries were performed via the surgical guide by one surgeon. Pre- and post-operative CBCT images were superimposed, and the positional and angular deviations between placed and planned implants were measured with metrology software. A total of 43 fully guided implants were placed, in which 25 implants were planned with the surface registration protocol. Implants planned based on the surface registration protocol had a larger mean angular deviation than the fiducial marker registration protocol. No significant differences were found for any deviations of the examined variables. Within the limits of this study, we concluded that the clinical accuracy of the sGIS planned with a fully digital workflow was consistent with the conventional workflow for partially edentulous patients.
Oxygen plasma with different treatment powers and durations was utilized to modify the biomedical pure titanium (Ti) surface in the present study. The superficial, microstructural and biological properties of the plasma-oxidized samples were investigated using the electron microscopy, X-ray photoemission spectroscopy, grazing incidence X-ray diffractometer, contact angle goniometer and blood clotting time assay. During different treatment powers and durations, the island-like nanostructural rutile-TiO2 layer and dimple-like nanostructural rutile-TiO2 layer were generated on the surfaces of the plasma-oxidized samples, respectively. It was also found that the plasma-oxidized sample with a rough oxide layer resulted in the formation of a higher wettability. Moreover, the blood clotting time assay indicated that the plasma-oxidized samples exhibited the adhesion behaviors of red blood cells. As the Ti surface underwent plasma oxidation at 280 W for 30 min, it not only generates a rough nanostructural rutile-TiO2 layer, but also presents an excellent hemocompatibility. Therefore, these findings demonstrate that oxygen plasma modification is a potential approach to promote the hemocompatibility of biomedical pure Ti surface.
Minimally invasive procedures were introduced in periodontics, which could enhance clinical outcomes and reduce post-operative discomfort. However, minimally invasive non-surgical periodontal therapy (MINST) as an alternative modality of conventional non-surgical root surface debridement has not been clearly evaluated by randomized controlled clinical trial. The present study aimed to investigate clinical outcomes and patients’ comfort feedback of MINST compared to conventional non-surgical periodontal therapy (CNST). Patients with moderate to severe periodontitis were included. Nine out of ten patients were recruited and completed the post-treatment re-evaluation in this study. Randomized split-mouth design, CNST and MINST on each side, was performed. Clinical parameters, including periodontal probing depth (PD), gingival recession (REC), clinical attachment level (CAL), and gingival bleeding on probing (BOP), were recorded on baseline, 1 month and 3 months post-treatment. Non-parametric statistics were used for analysis. PD, REC, CAL, and BOP were improved after treatment in both CNST and MINST groups. Comfort feedback and gingival recession showed better outcomes in the MINST group than in the CNST group. No statistical significance of parameters was found between CNST and MINST. Within the limitations, minimally invasive non-surgical periodontal therapy could be an alternative modality of conventional non-surgical periodontal therapy. Further studies are required to establish clinical protocol and evidence of MINST.
This study investigates the results of cell cultures on aluminum (Al) templates with flat-structures, micro-structures, nano-structures and micro/nano-structures. An Al template with flat-structure was obtained by electrolytic polishing; an Al template with micro-structure was obtained by micro-powder blasting; an Al template with nano-structure was obtained by aluminum anodization; and an Al template with micro/nano-structure was obtained by micro-powder blasting and then anodization. Osteoblast-like cells were cultured on aluminum templates with various structures. The microculture tetrazolium test assay was utilized to assess the adhesion, elongation, and proliferation behaviors of cultured osteoblast-like cells on aluminum templates with flat-structures, micro-structures, nano-structures, and micro/nano-structures. The results showed that the surface characterization of micro/nano-structure of aluminum templates had superhydrophilic property, and these also revealed that an aluminum template with micro/nano-structure could provide the most suitable growth situation for cell culture.
Periodontitis and chronic kidney disease are both chronic inflammatory diseases and share some common risk factors. This 3-month pilot study aimed to clarify whether non-surgical periodontal therapy is beneficial in clinical, biochemical, and microbiological conditions in patients with periodontitis and kidney failure. Kidney failure patients with moderate to severe periodontitis were recruited from two hospitals. Treatment group received non-surgical periodontal therapy, and control group received oral hygiene instruction only. Outcome assessments were conducted 1 and 3 months after treatment. Non-parametric tests were used to analyze the patient-level data. Periodontal site-level assessments were analyzed by Student t-test and paired t-test. Statistical significance was set at p-value < 0.05. A total of 11 subjects completed the study. There was no significant difference between groups in all-cause mortality, cardiovascular events, infection events, systemic parameters, and serum biomarkers. Comparing to control group, clinical periodontal parameters, gingival crevicular fluid interleukin-1β (IL-1β) level and periodontal pathogens showed significant improvement in the treatment group. Non-surgical periodontal treatment did not change systemic outcomes in kidney failure patients, but changed the local micro-environment.
Microtia is characterized as an incomplete auricular development and surgical reconstruction for microtia is still limited even with emerging developments. This study aimed to apply bionanomaterials (PRP/collagen scaffold) for human auricular neocartilage reconstruction by using microtia chondrocytes. The results showed that PRP (TGF‐β1 750 pg/mL and 1 ng/mL) increased cell viability of microtia chondrocytes during in vitro 9‐day cultures. Additionally, chondrogenic‐specific mRNA of Aggrecan and type II collagen (Col II) was significantly and continuously expressed with PRP treatment during the 21‐day in vitro expansion. Tissue engineering of auricular neocartilage was performed by seeding microtia chondrocytes in bionanomaterials (PRP/collagen scaffold) 3‐dimensional (3D) cultures. Immunohistochemistry (IHC) of Col II showed intensive signals between cells and matrix after 4‐week cultures. Conclusion. Our results demonstrated that PRP promotes proliferation and redifferentiation of microtia chondrocytes and provides regenerative potentials in auricular neocartilage reconstruction.