Mixed-flow pumps with adjustable blades are widely used in municipal, agricultural, and hydropower applications. However, a limitation of adjustable blades is that the influence of the water pressure in the pump causes the rotation angle to deviate, which not only reduces the hydraulic efficiency of the pump and increases energy consumption, but it is also detrimental to the stable operation of the pump. To investigate the influence of blade rotation angle deviations (BRADs) on the hydraulic pulsation characteristics of a mixed-flow pump, in this study, a three-dimensional unsteady numerical simulation was adopted to analyze the effects of seven BRAD design schemes on the energy performance, pressure pulsation characteristics, and axial and radial forces in the impeller. When the rotation angle of a single blade deviated counterclockwise, the optimal hydraulic efficiency point of the mixed-flow pump moved toward larger flow rates, and vice versa. Unlike a situation with no BRADs, when there were BRADs, the central symmetry of the low-pressure area near the suction surface of the impeller blades was destroyed. BRADs led to increases in the pressure pulsation amplitudes at the inlet and outlet of the impeller. The dominant pressure pulsation frequencies near the shroud side at the inlet and outlet of the impeller were not affected by BRADs (both of them were equal to the blade frequency). However, the amplitude of the dominant pressure pulsation frequency at the impeller outlet and the radial force of the impeller both increased with increases in the absolute value of the deviation angle. Moreover, when the rotation angle of a single blade was only in the counterclockwise direction, the axial force of the impeller increased. This study can provide an engineering reference for the stability of mixed-flow pumps with BRADs.
To investigate the size effect on the energy characteristics of axial flow pumps, this study scaled the original model size based on the head similarity principle, resulting in four size schemes (Schemes 2–4 correspond to 3, 5, and 10 times the size of Scheme 1, respectively). By solving the unsteady Reynolds-averaged Navier–Stokes (URANS) equations with the Shear Stress Transport (SST) k-omega turbulence model, the external characteristic parameters and internal flow field structures were predicted. Additionally, the spatial distribution of internal hydraulic losses was analyzed using entropy generation theory. The results revealed three key findings: (1) the efficiency of axial flow pumps significantly improves with increasing size ratio, with Scheme 4 exhibiting a 6.1% efficiency increase compared to Scheme 1; (2) as the size ratio increases, the entropy production coefficients of all hydraulic components decrease, with the impeller and guide vanes in Scheme 4 showing reductions of 55.1% and 56.5%, respectively, compared to Scheme 1; (3) the high entropy generation coefficient regions in the impeller and guide vanes are primarily concentrated near the rim, with their area decreasing as the size ratio increases. Specifically, the entropy production coefficients at the rim of impeller and guide vanes in Scheme 4 decreased by 84.85% and 58.2%, respectively, compared to Scheme 1. These findings provide valuable insights for the selection and optimization of axial flow pumps in applications such as cross-regional water transfer, agricultural irrigation, and urban drainage systems.
This study investigates the leakage vortex influence on pressure pulsation characteristics within a vertical axial flow pump. Three impeller configurations with blade root clearance (δ) of 2.7–8.0 mm were designed to analyze geometric effects on internal flow dynamics. Unsteady RANS simulations predicted flow structures under multiple operating conditions (0.8–1.2Qdes). Fast Fourier Transform (FFT) extracted frequency–domain and time–frequency characteristics of pressure pulsations in critical flow regions. Key results reveal: (1) δ enlargement expands low-pressure zones within blade channels due to enhanced leakage vortices; (2) leading-edge pulsation shows 8.2–11.7% reduction in peak-to-peak amplitude and fundamental frequency magnitude with increasing δ; (3) trailing-edge response exhibits non-monotonic behavior, with maximum amplitude at δ = 5.0 mm (42.2% increase at design flow). These findings demonstrate that blade root clearance optimization requires condition-dependent thresholds to balance leakage management and pulsation control.
Semi-open impeller sewage pumps are widely used for transporting solid-laden fluids due to their anti-clogging properties. However, unlike extensive research on clear water conditions, the specific mechanisms governing pressure instabilities under solid–liquid two-phase flows remain underexplored. This study investigates the unsteady flow field and pulsation characteristics of a Model 80WQ4QG pump using unsteady CFD simulations based on the Standard k−ϵ turbulence model and the Eulerian–Eulerian multiphase model. The effects of flow rate, particle size, and volume fraction were systematically analyzed. Results indicate that the blade-passing frequency (95 Hz) dominates the pressure spectra, with the volute tongue and impeller outlet identified as the most sensitive regions. While increased flow rates weaken fluctuations at the volute tongue, the presence of solid particles significantly amplifies them. Specifically, compared to single-phase flow, the pulsation amplitudes at the volute tongue increased by 68.15% with a 3.0 mm particle size and by 97.73% at a 20% volume fraction. Physically, this amplification is attributed to the intensified momentum exchange between phases and the enhanced turbulent flow disturbances induced by particle inertia at the rotor–stator interface. These findings clarify the particle-induced flow instability mechanisms, offering theoretical guidelines for optimizing pump durability in multiphase environments.
The influence of inflow angle on the stall characteristics of a vertical axial flow pump is investigated numerically by solving the unsteady Reynolds-averaged Navier–Stokes equations. The study predicts both performance parameters and internal flow structures under varying inflow conditions. It is found that as the deflection angle decreases, both the critical and deep stall points shift toward higher flow rates. For the −30° scheme, the design efficiency and design head decrease by 16.27% and increase by 19.59%, respectively, compared to the 0° scheme. As stall develops, an axisymmetric blockage region forms at the impeller inlet, which reduces axial velocity and increases the impeller’s angle of attack. Under design conditions, a smaller deflection angle exacerbates boundary layer separation near the blade leading edge, thereby weakening the local work capacity and intensifying turbulent dissipation. Furthermore, although a reduced deflection angle promotes an earlier onset of stall, it also leads to a decrease in the instability intensity of the stall flow field. These results reveal a critical trade-off: while a smaller deflection angle promotes an earlier stall onset, it effectively mitigates the intensity of stall instability, providing crucial guidance for optimizing the hydraulic design and operational stability of vertical axial flow pumps.
Blade tip leakage vortex (TLV) is a critical phenomenon in hydraulic machinery, which can significantly affect the internal flow characteristics and deteriorate the hydraulic performance. In this paper, the blade tip leakage flow and TLV characteristics in a novel dishwasher pump were investigated. The correlation between the vorticity distribution in various directions and the leakage vortices was established within a rotating coordinate system. The results show that the TLV in a composite impeller can be categorized into initial and secondary leakage vortices. The initial leakage vortex originates from the evolution of two corner vortices that initially form at different locations within the blade tip clearance. This vortex induces pressure fluctuations at the impeller inlet; its shedding is identified as the primary contributor to localized energy loss within the flow passage. These findings provide insights into TLVs in complex pump geometries and provide solutions for future pump optimization strategies.