The collapse and damage of large number of buildings during the November 26, 2019 (Mw 6,4) Albania earthquake caused 51 fatalities and injuries to at least 910 people. Most of collapsed or heavily damaged buildings were RC frame buildings. Although RC frame system is considered as very ductile seismic force-resisting system, its behaviour during earthquake highly depends on: (1) regularity in plan and elevation, and (2) global and local ductility. Based on the authors' visit to the earthquake-affected area on behalf of the Serbian Association of Earthquake Engineering and observations of collapsed and damaged buildings, it was concluded that among main reasons for underperformance of these flexible systems were inadequate analysis of interaction between infill walls and RC frames and reinforcement detailing of RC members.
Composite and mixed steel-concrete buildings, apart from high structural efficiency, have great potential in terms of reuse of structural elements at the end of the life of the buildings. The use of most demountable connectors can assure the reuse of steel elements; however, the reuse of reinforced concrete (RC) elements and embedded connectors remains relatively uncertain due to potential damage of connectors during disassembly. One of the possible solutions to assure the reuse of all components could be to use demountable connectors assembled from a demountable bolt and an embedded mechanical coupler with a rebar anchor. The key challenge for practical implementation of this type of demountable connector is adequate analysis under tension loads, due to a lack of design recommendations. This paper presents experimental investigations of the connection with demountable connectors with mechanical couplers and rebar anchors, located close to the concrete edge, under pure tension load. Nine pull-out tests on single connectors embedded in the RC element and six in-air tests on bare connectors were conducted in order to define the global behavior of the connection and the local behavior of the connector, respectively. The influence of concrete strength (concrete class C20/25 and C30/37), connector diameter (with M16 and M20 bolts), and bolt grade (grades 5.8 and 8.8) on the connection behavior was discussed in terms of resistance, stiffness, deformation capacity, and failure modes. Ultimate resistance varied from 77 kN to 135 kN, with failure modes shifting from taper thread stripping to bolt fracture based on bolt grade. Based on the obtained test results, analytical equations for the calculation of tension resistance and overall deformation capacity of the connection were proposed.
In the past few decades, demountable connectors have often been used for connections in composite and mixed steel-concrete structures to reduce construction time and costs. Furthermore, the application of demountable connectors enables the reuse of structural elements in these structures, which leads to sustainable design and a circular economy. In this paper, the demountable connector is made out of two parts: (1) mechanical coupler and rebar anchor placed in formwork before casting the concrete element, and (2) steel bolt used for connecting steel to the RC element. Although this connector is increasingly being used in contemporary building structures, its behaviour in composite connections is still insufficiently defined. The paper presents the results of experimental tests and numerical analysis of the connector with a mechanical coupler, focusing on the local behaviour of the tapered threaded connection between the mechanical coupler and rebar anchor.
11 March 2026 in Journal of Earthquake Engineering