Liviu-Coriolan Misca

Dr. Liviu-Coriolan Misca

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ASAnca Gabriela Stoianov
Anca Gabriela Stoianov
JPJenel Marian Pătrașcu
Jenel Marian Pătrașcu
Gheorghe Bogdan HogeaGheorghe Bogdan Hogea
Gheorghe Bogdan Hogea
Bogdan AndorBogdan Andor
Bogdan Andor
SFSorin Florescu
Sorin Florescu
JJJenel Marian Pătrașcu Jr.
Jenel Marian Pătrașcu Jr.
Posterior cruciate ligament (PCL) injuries, though less common than other knee ligament injuries, pose significant management challenges. This study aimed to systematically review and analyze the current evidence on the use of point-of-care ultrasound (POCUS) for the evaluation and management of PCL injuries. It was hypothesized that POCUS has comparable diagnostic accuracy to magnetic resonance imaging (MRI) and that the use of POCUS improves patient outcomes and reduces healthcare costs. A comprehensive systematic review of articles published up to April 2023 was conducted using PubMed, Web of Science, Cochrane, and Scopus databases and adhered to the PRISMA guidelines. Studies were selected based on relevance to the research question, with a focus on diagnostic accuracy, reliability, clinical utility, and cost-effectiveness of POCUS in PCL injuries. Seven studies, analyzing a total of 242 patients with PCL injuries, were included. The reported sensitivity and specificity of POCUS for diagnosing PCL injuries ranged from 83.3% to 100% and 86.7% to 100%, respectively, across the studies. In one study, POCUS demonstrated a positive predictive value (PPV) of 87.9% and a negative predictive value (NPV) of 82.4%. Additionally, three studies reported 100% accuracy in PCL injury detection using POCUS, suggesting a substantial potential for cost savings by eliminating the need for MRI. This systematic review supports the use of POCUS in the evaluation and management of PCL injuries, suggesting that POCUS is a reliable, cost-effective tool with high diagnostic accuracy comparable to that of MRI, offering the potential to improve patient outcomes and reduce healthcare costs. The data collated in this review can inform clinical practice and guide future research in the field.

15 April 2025 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
OMOana Maria Misca
Oana Maria Misca
LMLiviu-Coriolan Misca
Liviu-Coriolan Misca
BHBogdan Huzum
Bogdan Huzum
ANAndreea-Adriana Neamțu
Andreea-Adriana Neamțu
SCSimona Cerbu
Simona Cerbu
AMAndrei Gheorghe Marius Motoc
Andrei Gheorghe Marius Motoc
Background: Fluoroquinolone-induced tendinopathy is a clinically significant adverse effect associated with this class of antibiotics, particularly affecting the Achilles tendon. Despite its growing recognition, the precise pathophysiological mechanisms remain incompletely understood, with hypotheses referencing increased matrix metalloproteinase activity, collagen degradation, and oxidative stress. Methods: This prospective randomized pilot study evaluates the potential protective effectiveness of vitamin E and selenium supplementation in mitigating fluoroquinolone-induced tendinopathy. The study was conducted on 25 patients receiving 500 mg/day levofloxacin antibiotherapy, randomly divided into a control group and an experimental group—vitamin E (400 IU/day) and selenium (200 µg/day), oral supplementation for 28 days. Clinical assessment of the pain level through the VAS score and of functionality through the VISA-A score was performed, alongside ultrasound imaging of the Achilles tendon. To assess potential toxicity and ensure adherence to the supplementation protocol, serial biochemical analyses of serum vitamin E and selenium were performed at predetermined intervals. Results: A significant improvement was observed in pain scores (p = 0.0120) and functional outcomes (p = 0.0340) when comparing the control and experimental groups at the three-month follow-up. Ultrasound analysis revealed reduced tendon thickness and neovascularization, supporting structural recovery. Although the incidence of tendinopathy was lower in the interventional group (13.3% vs. 40%), statistical significance was not reached, possibly due to the small sample size. Conclusions: These findings suggest that antioxidant supplementation with vitamin E and selenium may provide a protective effect against fluoroquinolone-induced tendinopathy, warranting further investigation in larger randomized clinical trials.

15 September 2022 in Mædica
Verified
Journal Article
Closed access
ASAnca Gabriela Stoianov
Anca Gabriela Stoianov
JPJenel Marian Patrascu
Jenel Marian Patrascu
BHBogdan Gheorghe Hogea
Bogdan Gheorghe Hogea
BABogdan Andor
Bogdan Andor
SFSorin Florescu
Sorin Florescu
LMLiviu-Coriolan Misca
Liviu-Coriolan Misca
Objective:The current study included a total of 10 patients, both males and females, who gave their consent to participate in the study and underwent clinical and ultrasound examinations. All patients had a history of carpal tunnel symptoms like tingling, numbness, nocturnal paraesthesia and weakness of the hand (loss of pinch and grip strength) for more than 12 months.

15 September 2025 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
LMLiviu-Coriolan Misca
Liviu-Coriolan Misca
CCCristian Croicu
Cristian Croicu
ALAdrian Emil Lazarescu
Adrian Emil Lazarescu
MSMihai Alexandru Sandesc
Mihai Alexandru Sandesc
JJJenel Marian Pătrașcu Jr.
Jenel Marian Pătrașcu Jr.
JPJenel Marian Pătrașcu
Jenel Marian Pătrașcu
Introduction: Intramedullary nailing is widely used for long bone fractures. Traditional systems are reliable, but they present some complications regarding lack of modularity or possible growth plate damage. Methods: A novel locking rod–screw system featuring a central rod and a grooved screw with a secondary interlocking mechanism was developed and tested. Mechanical testing followed ASTM F543 and ISO 6475 standards using a 3.0 mm steel alloy prototype. Results: The system withstood mechanical testing >200,000 cycles at loads up to 200 N with no rates of failure or loosening, significantly outperforming other implants of the same size (3.0 mm TENS). Conclusions: The proposed implant demonstrates superior biomechanical performance in vitro, enabled by its unique hollow screw and secondary locking configuration. This modular and minimally invasive system shows promise for use in cases of smaller long bones, personalized paediatric fractures, and all types of diaphyseal fractures, but does warrant in vivo validation.

29 September 2025 in Orthopedic Reviews
Verified
Journal Article
Open access
PDF file
LMLiviu-Coriolan Misca
Liviu-Coriolan Misca
CCCristian C. Croicu
Cristian C. Croicu
ALAdrian E. Lazarescu
Adrian E. Lazarescu
MSMihai A. Sandesc
Mihai A. Sandesc
JPJenel M. Patrascu
Jenel M. Patrascu
SFSorin Florescu
Sorin Florescu
Background/Objectives: Femoral and tibial shaft fractures are among the most common long bone fractures. This study aims to assess and compare the economic impact of these two approaches by evaluating: direct costs (implant pricing, instrumentation and operating room expenses) and indirect costs (complication rates and reoperation expenses). Methods: This study is a comparative cost-analysis study aimed at evaluating the financial burden of stocking an orthopaedic theatre with IM nails versus locking rods used for the treatment of femoral and tibial shaft fractures. The analysis will focus on the costs associated with the procurement; storage and utilization of these implant systems, using publicly available data, manufacturer pricing and relevant industry reports. Results: In this comparison, IM nailing is slightly more expensive than treating the same fractures by universal locking rod systems with the cost difference ranging between $3,473 and $5,846. The main contributors to the cost difference include the slightly higher surgical time for IM nailing, as well as higher staffing and operating room costs in addition to higher complication rates reported. Conclusions: While universal locking rods may have a higher upfront cost, they can reduce hospital inventory needs through their innovative designs which can potentially lead to long term cost savings, as one system can accommodate a bigger range of fractures.

26 August 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
OMOana Maria Misca
Oana Maria Misca
LMLiviu-Coriolan Misca
Liviu-Coriolan Misca
ANAndreea-Adriana Neamțu
Andreea-Adriana Neamțu
Laura MaghiarLaura Maghiar
Laura Maghiar
CCCristian Croicu
Cristian Croicu
AMAndrei Gheorghe Marius Motoc
Andrei Gheorghe Marius Motoc
Background/Objectives: Fluoroquinolones cause Achilles tendinopathy within a narrow, early therapeutic window, yet preventive strategies given alongside these antibiotics remain largely untested. This exploratory pilot study assessed whether four mechanistically distinct adjuvants attenuated histopathological tendon change in a rabbit model of levofloxacin exposure. Methods: Twenty-one male New Zealand White rabbits received oral levofloxacin (100 µg/kg/day, seven days). A contralateral-limb design yielded 42 tendons (two cohorts provided paired limb-specific comparisons and a third cohort received the systemic intervention). Animals were allocated to various groups, receiving platelet-rich plasma (PRP), injectable porcine collagen, oral vitamin E + selenium, topical essential oils with augmented soft-tissue mobilization (ASTM), or a levofloxacin-only control. The main outcome was a modified Bonar composite (tenocyte morphology, cellularity, vascularity, paratendinous fibrosis; 0–12) at three months; additional outcomes were the individual domains and ultrasonographic tendon thickness. Results: Composite scores were low throughout (group medians 2.0–4.0) and did not differ between groups (H = 3.663, p = 0.45); no domain differed, and the untreated control did not show the greatest change. Within animals, collagen-treated tendons scored higher than the paired essential-oil tendons (median difference +3.0, nominal p = 0.031, Bonferroni-adjusted p = 0.062). Tendon thickness increased by day 14 only with vitamin E + selenium (+14.1%; p = 0.003, and p = 0.006 adjusted for baseline); this finding arose in a separate cohort with thinner baseline tendons, cannot be confidently attributed to the intervention, and was unrelated to histopathology (ρ = −0.02, p = 0.91). Macroscopic findings differed between groups (nominal p = 0.031) without predicting tissue grade. Conclusions: No statistically detectable difference in the study-specific four-domain composite was identified among the treatment conditions; the study lacked a levofloxacin-free control and could not provide a definitive efficacy assessment. The model produced only mild pathology, limiting its power, and neither imaging nor gross inspection predicted tissue-level change. These preliminary observations are hypothesis-generating and are intended to inform the design of an adequately powered confirmatory study. The findings are inconclusive for efficacy; the design cannot distinguish lack of adjuvant efficacy from failure of the model to induce measurable disease.