Critically ill polytrauma patients have increased production of free radicals (FRs) and consequent alterations in biochemical pathways, as well as disruption of cellular integrity, due to increased lipid peroxidation. The aim of this study was to investigate several biomarkers associated with increased oxidative stress in critically ill polytrauma patients, and to evaluate the effect of antioxidant treatment on the clinical outcome in these patients. A total of 67 polytrauma patients from an intensive care unit met the selection criteria. Antiox group included 35/67 patients who received antioxidant therapy, while 32/67 patients without antioxidant treatment were considered as control group. Antioxidant therapy consisted of simultaneous administration of Vitamin C (sodium ascorbate) and N-acetylcysteine, through continuous intravenous infusion. Clinical and paraclinical evaluation of the patients was performed daily until discharge or death. At admission, laboratory parameters did not differ significantly between two groups. At discharge/upon death, statistically significant differences in favor of Antiox group were observed in the following parameters: thrombocytes, activated partial thromboplastin time, prothrombin time, total bilirubin, total cholesterol, high-density lipoproteins, low-density lipoproteins, erythrocyte sedimentation rate, interleukin 6 (all p = 0.0001), total protein (p = 0.0005), serum albumin (p = 0.0004), lactate dehydrogenase (p = 0.0006), and C-reactive protein (p = 0.0014). Starting from day 5, the APACHE II score was significantly decreased in Antiox versus control group (p < 0.05). Finally, the sepsis incidence and mortality rate were significantly lower in Antiox group (p < 0.05). Decreasing the level of oxidative stress by antioxidant substances significantly correlated with a better prognosis and outcome in our patients. Further studies should elucidate more clearly the mechanism of action of antioxidants in critically ill polytrauma patients.
Laparoscopic cholecystectomy is one of the most frequently performed interventions in general surgery departments. Some of the most important aims in achieving perioperative stability in these patients is diminishing the impact of general anesthesia on the hemodynamic stability and the optimization of anesthetic drug doses based on the individual clinical profile of each patient. The objective of this study is the evaluation of the impact, as monitored through entropy (both state entropy (SE) and response entropy (RE)), that the depth of anesthesia has on the hemodynamic stability, as well as the doses of volatile anesthetic. A prospective, observational, randomized, and monocentric study was carried out between January and December 2019 in the Clinic of Anesthesia and Intensive Care of the “Pius Brînzeu” Emergency County Hospital in Timișoara, Romania. The patients included in the study were divided in two study groups: patients in Group A (target group) received multimodal monitoring, which included monitoring of standard parameters and of entropy (SE and RE); while the patients in Group B (control group) only received standard monitoring. The anesthetic dose in group A was optimized to achieve a target entropy of 40–60. A total of 68 patients met the inclusion criteria and were allocated to one of the two study groups: group A (N = 43) or group B (N = 25). There were no statistically significant differences identified between the two groups for both demographical and clinical characteristics (p > 0.05). Statistically significant differences were identified for the number of hypotensive episodes (p = 0.011, 95% CI: [0.1851, 0.7042]) and for the number of episodes of bradycardia (p < 0.0001, 95% CI: [0.3296, 0.7923]). Moreover, there was a significant difference in the Sevoflurane consumption between the two study groups (p = 0.0498, 95% CI: [−0.3942, 0.9047]). The implementation of the multimodal monitoring protocol, including the standard parameters and the measurement of entropy for determining the depth of anesthesia (SE and RE) led to a considerable improvement in perioperative hemodynamic stability. Furthermore, optimizing the doses of anesthetic drugs based on the individual clinical profile of each patient led to a considerable decrease in drug consumption, as well as to a lower incidence of hemodynamic side-effects.
Introduction: Intramedullary nailing is widely used for long bone fractures. Traditional systems are reliable, but they present some complications regarding lack of modularity or possible growth plate damage. Methods: A novel locking rod–screw system featuring a central rod and a grooved screw with a secondary interlocking mechanism was developed and tested. Mechanical testing followed ASTM F543 and ISO 6475 standards using a 3.0 mm steel alloy prototype. Results: The system withstood mechanical testing >200,000 cycles at loads up to 200 N with no rates of failure or loosening, significantly outperforming other implants of the same size (3.0 mm TENS). Conclusions: The proposed implant demonstrates superior biomechanical performance in vitro, enabled by its unique hollow screw and secondary locking configuration. This modular and minimally invasive system shows promise for use in cases of smaller long bones, personalized paediatric fractures, and all types of diaphyseal fractures, but does warrant in vivo validation.