Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient‐specific MRI‐based CFD simulations. Ten time‐resolved MRI data sets with and without velocity encoding were obtained to reconstruct the aorta and set hemodynamic boundary conditions for simulations. Aortic hemodynamics after virtual valve replacement with a biological and mechanical valve prosthesis were investigated. Wall shear stress (WSS), secondary flow degree (SFD), transvalvular pressure drop (TPD), turbulent kinetic energy (TKE), and normalized flow displacement (NFD) were evaluated to characterize valve‐induced hemodynamics. The biological prostheses induced significantly higher WSS (medians: 9.3 vs. 8.6 Pa, P = 0.027) and SFD (means: 0.78 vs. 0.49, P = 0.002) in the ascending aorta, TPD (medians: 11.4 vs. 2.7 mm Hg, P = 0.002), TKE (means: 400 vs. 283 cm2/s2, P = 0.037), and NFD (means: 0.0994 vs. 0.0607, P = 0.020) than the mechanical prostheses. The differences between the prosthesis types showed great inter‐patient variability, however. Given this variability, a patient‐specific evaluation is warranted. In conclusion, MRI‐based CFD offers an opportunity to assess the interactions between prosthesis and patient‐specific boundary conditions, which may help in optimizing surgical decision making and providing additional guidance to clinicians.
25 May 2019 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: Complex blood flow profiles in the aorta are known to contribute to vessel dilatation. We studied flow profiles in the aorta in patients with aortic valve disease before and after surgical aortic valve replacement (AVR). METHODS: Thirty-four patients with aortic valve disease underwent 4-dimensional velocity-encoded magnetic resonance imaging before and after AVR (biological valve = 27, mechanical valve = 7). Seven healthy volunteers served as controls. Eccentricity (ES) and complex flow scores (CFS) were determined from the degree of helicity, vorticity and eccentricity of flow profiles in the aorta. Model-based therapy planning was used in 4 cases to improve in silico postoperative flow profiles by personalized adjustment of size, rotation and angulation of the valve as well as aorta diameter. RESULTS: Patients with aortic valve disease showed more complex flow than controls [median ES 2.5 (interquartile range (IQR) 2.3–2.7) vs 1.0 (IQR 1.0–1.0), P < 0.001, median CFS 4.7 (IQR 4.3–4.8) vs 1.0 (IQR 1.0–2.0), P < 0.001]. After surgery, flow complexity in the total patient cohort was reduced, but remained significantly higher compared to controls [median ES 2.3 (IQR 1.9–2.3) vs 1.0 (IQR 1.0–1.0), P < 0.001, median CFS 3.8 (IQR 3.0–4.3) vs 1.0 (IQR 1.0–2.0), P < 0.001]. In patients after mechanical AVR, flow complexity fell substantially and showed no difference from controls [median ES 1.0 (IQR 1.0–2.3) vs 1.0 (IQR 1.0–1.0), P = 0.46, median CFS 1.0 (IQR 1.0–3.3) vs 1.0 (IQR 1.0–2.0), P = 0.71]. In all 4 selected cases (biological, n = 2; mechanical, n = 2), model-based therapy planning reduced in silico complexity of flow profiles compared to the existing post-surgical findings [median ES 1.7 (IQR 1.4–1.7) vs 2.3 (IQR 2.3–2.3); CFS 1.7 (IQR 1.4–2.5) vs 3.8 (IQR 3.3–4.3)]. CONCLUSIONS: Abnormal flow profiles in the aorta more frequently persist after surgical AVR. Model-based therapy planning might have the potential to optimize treatment for best possible individual outcome. Clinical trial registration number: clinicaltrials.gov NCT03172338, 1 June 2017, retrospectively registered; NCT02591940, 30 October 2015, retrospectively registered.
25 March 2024 in IEEE Transactions on Biomedical Engineering
Objective: Major challenges for clinical applications of in silico medicine are limitations in time and computational resources. Computational approaches should therefore be tailored to specific applications with relatively low complexity and must be verified and validated against clinical gold standards. Methods: This study performed computational fluid dynamics simulations of left ventricular hemodynamics of different complexity based on shape reconstruction from steady state gradient echo magnetic resonance imaging (MRI) data. Computed flow results of a rigid wall model (RWM) and a prescribed motion fluid-structure interaction (PM-FSI) model were compared against phase-contrast MRI measurements for three healthy subjects. Results: Extracted boundary conditions from the steady state MRI sequences as well as computed metrics, such as flow rate, valve velocities, and kinetic energy show good agreement with in vivo flow measurements. Regional flow analysis reveals larger differences. Conclusion: Basic flow structures are well captured with RWM and PM-FSI. For the computation of further biomarkers like washout or flow efficiency, usage of PM-FSI is required. Regarding boundary-near flow, more accurate anatomical models are inevitable. Significance: These results delineate areas of application of both methods and lay a foundation for larger validation studies and sensitivity analysis for healthy and diseased cases, being an essential step upon clinical translations.
Computational fluid dynamics (CFD) carry the potential to provide detailed insights into intraventricular hemodynamics and complement in vivo flow measurement techniques. A variety of CFD approaches emerged in recent years, mostly building solely on medical image data as patient‐specific input. While the utilized medical imaging method and chosen CFD approach both influence the computed hemodynamics, thereto related differences are rarely investigated. The present study addresses this issue with an inter‐(imaging)‐modality and inter‐model comparison of intracardiac flow computations. Magnetic resonance imaging (MRI) and transthoracic echocardiography (TTE) data of a volunteer were acquired and used to reconstruct the anatomical structures. For each modality, the reconstructed shapes were applied in two previously introduced CFD approaches to compute whole‐cycle ventricular flow patterns. While both methods involved benefits and challenges, similar valve velocities were computed, being in accordance with in vivo 4D flow MRI and pulsed‐wave Doppler velocity measurements (systolic peak velocity: 1.24–1.26 m/s (MRI), 0.9–1.25 m/s (TTE); diastolic peak velocity: 0.54 m/s (MRI), 0.59–0.75 m/s (TTE)). A detailed flow analysis with vortex formation, kinetic energy, and mid‐ventricular velocities indicated the computed inter‐modality differences to be larger than inter‐method ones. Quantitatively, this could be observed in the direct flow rate ( inter‐modality: 13, inter‐method, 3). These results help to gain trust in CFD approaches to compute intraventricular flow and emphasize the importance of standardized input data. Future studies, however, should consider a broader data base.
Background: Recent studies suggest that any degree of patient-prosthesis mismatch (PPM) increases morbidity and mortality after surgical aortic valve replacement (SAVR). We used computational fluid dynamics simulations to test the influence of prosthesis size and physical activity after SAVR. Methods: In 10 patients with aortic valve stenosis, virtual SAVR was performed. Left ventricular outflow tract stroke volume and flow direction information (4D Flow) were used, and an increase in stroke volume of 25% was chosen for simulating physical activity. Pressure gradients (DP max) across the aortic valve and blood flow profiles in the ascending aorta were calculated and predicted for three different valve sizes at rest and under stress in every patient. Results: Gradients across the aortic valve were significantly lower using larger valves; however, they were not normalized after SAVR (DP max [mmHg] norm/smaller/reference/larger valve = 6/14/12/9 mmHg, <0.01 compared to norm). Physical activity simulation increased DP max in all patients and across all valve sizes (DP max [mmHg] rest versus stress for the smaller/reference/larger valve = 14 vs. 23, 12 vs. 18, 9 vs. 14). Blood flow profiles did not normalize after SAVR and remained unaffected by physical activity. Gradients differed between mild and moderate stenosis between different therapy options and even showed moderate to severe stenosis under simulated physical activity. Conclusions: Prosthesis size and physical activity simulation have a significant influence on gradients across the aortic valve. Virtual therapy planning using patient-specific data might help to improve outcomes after SAVR in the future.