Katharina Vellguth

Katharina Vellguth

Auto-generated profile, based on publicly available information

Katharina Vellguth

Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin 1 , Berlin

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KVKatharina Vellguth
Katharina Vellguth
JBJan Brüning
Jan Brüning
LGLeonid Goubergrits
Leonid Goubergrits
LTLennart Tautz
Lennart Tautz
AHAnja Hennemuth
Anja Hennemuth
TKTitus Kuehne
Titus Kuehne

19 June 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KVKatharina Vellguth
Katharina Vellguth
JBJan Brüning
Jan Brüning
LTLennart Tautz
Lennart Tautz
FDFranziska Degener
Franziska Degener
IWIsaac Wamala
Isaac Wamala
LGLeonid Goubergrits
Leonid Goubergrits

24 August 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
KVKatharina Vellguth
Katharina Vellguth
FBFabian Barbieri
Fabian Barbieri
MRMarkus Reinthaler
Markus Reinthaler
MKMario Kasner
Mario Kasner
ULUlf Landmesser
Ulf Landmesser
LGLeonid Goubergrits
Leonid Goubergrits
Background: Transcatheter edge-to-edge repair (TEER) has developed from innovative technology to an established treatment strategy of mitral regurgitation (MR). The risk of iatrogenic mitral stenosis after TEER is, however, a critical factor in the conflict of interest between maximal reduction of MR and minimal impairment of left ventricular filling. We aim to investigate systematically the impact of device position on the post treatment hemodynamic outcome by involving the patient-specific segmentation of the diseased mitral valve.Materials and methods: Transesophageal echocardiographic image data of ten patients with severe MR (age: 57 ± 8 years, 20% female) were segmented and virtually treated with TEER at three positions by using a position based dynamics approach. Pre- and post-interventional patient geometries were preprocessed for computational fluid dynamics (CFD) and simulated at peak-diastole with patient-specific blood flow boundary conditions. Simulations were performed with boundary conditions mimicking rest and stress. The simulation results were compared with clinical data acquired for a cohort of 21 symptomatic MR patients (age: 79 ± 6 years, 43% female) treated with TEER.Results: Virtual TEER reduces the mitral valve area (MVA) from 7.5 ± 1.6 to 2.6 ± 0.6 cm2. Central device positioning resulted in a 14% smaller MVA than eccentric device positions. Furthermore, residual MVA is better predictable for central than for eccentric device positions (R2 = 0.81 vs. R2 = 0.49). The MVA reduction led to significantly higher maximal diastolic velocities (pre: 0.9 ± 0.2 m/s, post: 2.0 ± 0.5 m/s) and pressure gradients (pre: 1.5 ± 0.6 mmHg, post: 16.3 ± 9 mmHg) in spite of a mean flow rate reduction by 23% due to reduced MR after the treatment. On average, velocities were 12% and pressure gradients were 25% higher with devices in central compared to lateral or medial positions.Conclusion: Virtual TEER treatment combined with CFD is a promising tool for predicting individual morphometric and hemodynamic outcomes. Such a tool can potentially be used to support clinical decision making, procedure planning, and risk estimation to prevent post-procedural iatrogenic mitral stenosis.

25 March 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
LOL. Obermeier
L. Obermeier
MWM. Wiegand
M. Wiegand
FHFlorian Hellmeier
Florian Hellmeier
CMC. Manini
C. Manini
TKT. Kuehne
T. Kuehne
KVK. Vellguth
K. Vellguth
Objective: Major challenges for clinical applications of in silico medicine are limitations in time and computational resources. Computational approaches should therefore be tailored to specific applications with relatively low complexity and must be verified and validated against clinical gold standards. Methods: This study performed computational fluid dynamics simulations of left ventricular hemodynamics of different complexity based on shape reconstruction from steady state gradient echo magnetic resonance imaging (MRI) data. Computed flow results of a rigid wall model (RWM) and a prescribed motion fluid-structure interaction (PM-FSI) model were compared against phase-contrast MRI measurements for three healthy subjects. Results: Extracted boundary conditions from the steady state MRI sequences as well as computed metrics, such as flow rate, valve velocities, and kinetic energy show good agreement with in vivo flow measurements. Regional flow analysis reveals larger differences. Conclusion: Basic flow structures are well captured with RWM and PM-FSI. For the computation of further biomarkers like washout or flow efficiency, usage of PM-FSI is required. Regarding boundary-near flow, more accurate anatomical models are inevitable. Significance: These results delineate areas of application of both methods and lay a foundation for larger validation studies and sensitivity analysis for healthy and diseased cases, being an essential step upon clinical translations.

16 May 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
LOLukas Obermeier
Lukas Obermeier
MWMoritz Wiegand
Moritz Wiegand
TKTitus Kuehne
Titus Kuehne
VFVolkmar Falk
Volkmar Falk
CKChristoph Knosalla
Christoph Knosalla
KVKatharina Vellguth
Katharina Vellguth
Surgical ventricular restoration (SVR) excludes scarred myocardium after myocardial infarction to restore shape and contractility of dilated, aneurysmal left ventricles (LVs). Detailed changes in intracardiac hemodynamics following the surgery are not fully investigated. In this study, digital replicas of the patient's LV were used to study the hemodynamic impact of successful SVR. The digital replicas were built based on pre-operative and post-operative cardiac computed tomography data of nine patients (3females, 60 ± 13years) who underwent successful SVR (significant reduction in heart failure symptoms). The computational framework was used to calculate LV morphology, dynamics, and intracardiac hemodynamics using image-based computational fluid dynamics (CFD). SVR successfully reduced the LV volumes. Morphological analysis showed restoration of myocardial wall thickness in aneurysmal regions (5.5 ± 2.0 vs. 8.6 ± 3.0 mm) and an increased end-diastolic sphericity (sphericity index 0.39 ± 0.07 vs. 0.46 ± 0.07). No distinct flow alterations could be linked thereto. CFD revealed a higher post-operative kinetic energy level (diastolic maximum 10.0 ± 7.6 vs. 16.8 ± 9.1mJ) and an improved global washout (29.5 ± 9.7 vs. 10.3 ± 6.4% after five cycles), which correlated to increases in volume-curve-derived diastolic energy gain and ejection fraction, respectively. Flow efficiency improved by means of an increased end-diastolic surface-averaged vortex strength (16.2 ± 5.1 vs. 30.0 ± 15.01/s) and a decreased normed diastolic energy loss (18.9 ± 3.9 vs. 15.0 ± 3.7%). The hemodynamic filling forces in diastole were aligned with the LV long axis before and after surgery and correlated with LV contractility. In summary, the digital patient replicas facilitated a detailed analysis and showed favorable flow changes with successful SVR.

23 January 2024 in GAMM-Mitteilungen
Verified
Journal Article
Open access
LOLukas Obermeier
Lukas Obermeier
JKJana Korte
Jana Korte
KVKatharina Vellguth
Katharina Vellguth
FBFabian Barbieri
Fabian Barbieri
FHFlorian Hellmeier
Florian Hellmeier
LGLeonid Goubergrits
Leonid Goubergrits
Computational fluid dynamics (CFD) carry the potential to provide detailed insights into intraventricular hemodynamics and complement in vivo flow measurement techniques. A variety of CFD approaches emerged in recent years, mostly building solely on medical image data as patient‐specific input. While the utilized medical imaging method and chosen CFD approach both influence the computed hemodynamics, thereto related differences are rarely investigated. The present study addresses this issue with an inter‐(imaging)‐modality and inter‐model comparison of intracardiac flow computations. Magnetic resonance imaging (MRI) and transthoracic echocardiography (TTE) data of a volunteer were acquired and used to reconstruct the anatomical structures. For each modality, the reconstructed shapes were applied in two previously introduced CFD approaches to compute whole‐cycle ventricular flow patterns. While both methods involved benefits and challenges, similar valve velocities were computed, being in accordance with in vivo 4D flow MRI and pulsed‐wave Doppler velocity measurements (systolic peak velocity: 1.24–1.26 m/s (MRI), 0.9–1.25 m/s (TTE); diastolic peak velocity: 0.54 m/s (MRI), 0.59–0.75 m/s (TTE)). A detailed flow analysis with vortex formation, kinetic energy, and mid‐ventricular velocities indicated the computed inter‐modality differences to be larger than inter‐method ones. Quantitatively, this could be observed in the direct flow rate ( inter‐modality: 13, inter‐method, 3). These results help to gain trust in CFD approaches to compute intraventricular flow and emphasize the importance of standardized input data. Future studies, however, should consider a broader data base.