29 August 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZLZhixuan Li
Zhixuan Li
YXYing Xue
Ying Xue
YTYuan Tang
Yuan Tang
NCNan Chen
Nan Chen
CYConghuan Yang
Conghuan Yang
Line-Commutated Converter (LCC) based High-Voltage Direct Current (HVDC) systems are susceptible to commutation failure (CF) during fault recovery not only for faults at inverter, but also for faults at rectifier side. Although the mechanism of CF under each scenario (fault at inverter and fault at rectifier) have been widely discussed, no existing methods can mitigate CFs under both scenarios. This is because the lack of detailed comparative analysis for the root cause of CFs under both scenarios. In this study, it is shown that the essence of CF during fault recovery for faults at both ends are in fact the same – long duration of CC control at both end converters and inability of CEA control to maintain commutation margin after control mode switching during fault recovery. As a result, the inverter cannot maintain a stable operating point during fault recovery. Based on this, an adaptive advancement (beta) angle (ABA) control is proposed that can mitigate CFs during fault recovery for faults at both ends. The proposed control features a direct control of inverter advancement angle that ensures a sufficient commutation margin during recovery. At the same time, the negative impacts of the increase of reactive power consumption are minimized by avoiding the ‘over advancement’ of inverter firing angle. From the V-I trajectory point of view, the trajectory of the system is constrained at the stable operating point during recovery process. PSCAD simulation demonstrates the effectiveness of the proposed method.

27 June 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YXYing Xue
Ying Xue
YCYiping Chen
Yiping Chen
WZWaisheng Zheng
Waisheng Zheng
YTYuan Tang
Yuan Tang
ZLZhixuan Li
Zhixuan Li
WTWenhu Tang
Wenhu Tang
Power systems worldwide are transforming into renewable-dominated ones that require significant grid flexibility. While extensive research has been done on flexibility from the generation or demand side, there is a significant lack of research on studying flexibility from the grid side. Therefore, this paper proposes a primary frequency response sharing strategy using LCC-HVDC for inverter frequency control. Under an inverter frequency event, the proposed method imposes a controlled load change that is proportional to the inverter AC frequency deviation on the rectifier AC network. This in impact activates the primary frequency response from the rectifier side to support the inverter AC frequency (i.e., sharing of primary frequency response). The level of support and the coupled dynamics of rectifier and inverter frequencies are quantified by the developed mathematical model. The model reveals that the inverter load change is affecting the rectifier AC frequency through two cascaded 2 nd order transfer functions. With the developed model and the desired frequency nadirs at both AC systems, the controller parameters of the proposed method are calculated. This ensures that appropriate level of primary frequency response is shared without jeopardizing the frequency performance of rectifier AC system. The effectiveness of the proposed method is demonstrated using a modified four-generator two-area system. Estimation errors of network inertia and droop constants are discussed.

8 April 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZZZhiyi Zhao
Zhiyi Zhao
YXYing Xue
Ying Xue
ZCZhongda Chu
Zhongda Chu
YGYe Guo
Ye Guo
ZLZhixuan Li
Zhixuan Li
GSGoran Strbac
Goran Strbac
The frequency nadir (FN) is a crucial indicator for frequency stability. Accurate FN estimation helps operators assess stability risks and determine the required Primary Frequency Response (PFR) reserves. Existing analytical methods for FN estimation face problems such as poor applicability, inability to be numerically solved for FN, and a lack of analysis of the governor-turbine model needed to establish a low-order PFR model. This paper employs adaptable low-order fitting approaches to the governor-turbine model to propose a generic low-order PFR model. This model is applicable to various governor-turbine systems and scenarios where converter-based systems participate in PFR. Its low-order characteristic enables efficient numerical calculation of FN and quantitative tuning of control parameters for converter-based systems. To demonstrate the accuracy and applicability of the proposed method, case studies for FN prediction are carried out on the IEEE 9/39 bus systems, and parameter tuning for the High Voltage Direct Current (HVDC) system is presented when the HVDC provides frequency support to the AC system.

4 June 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZLZhixuan Li
Zhixuan Li
YXYing Xue
Ying Xue
QFQiang Fu
Qiang Fu
YCYiping Chen
Yiping Chen
WZWaisheng Zheng
Waisheng Zheng
CYConghuang Yang
Conghuang Yang
The Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) system is considered an efficient solution for providing functional support to asynchronously interconnected systems. However, this study demonstrates that frequency support from VSC-HVDC systems can lead to low-frequency power oscillations (LFPOs) due to the interaction between the frequency control and the frequency dynamics of AC grids. For convenience, a practical instance of a 0.25 Hz LFPO observed in the LUXI back-to-back VSC-HVDC project in the China is reported in detail. In this project, the VSC-HVDC system is designed with a frequency control (namely, Co-frequency control) to eliminate frequency divisions between the two asynchronous AC grids under normal operation conditions. Based on the damping torque method, the analysis concludes that the observed LFPO is induced by the interaction between the Co-frequency control and the frequency dynamics of the synchronous generators in AC systems, and is governed by the parameters of the Co-frequency control. To address the LFPO, two damping control schemes are proposed. Finally, all conclusions and findings are validated through EMT simulations. To the best of our knowledge, this is the first report of practical oscillations caused by the frequency control of VSC-HVDC systems, which is meaningful for engineers and researchers, by providing insights about the stable operation of asynchronously interconnected systems.

13 November 2024 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZLZhixuan Li
Zhixuan Li
YXYing Xue
Ying Xue
YCYiping Chen
Yiping Chen
NCNan Chen
Nan Chen
CYConghuan Yang
Conghuan Yang
JHJiyu Huang
Jiyu Huang
Modern power systems require significant grid flexibility. As the AC transmission lines are passive and cannot be controlled, grid flexibility in the transmission system can only be provided by actively controlling High-Voltage Direct Current (HVDC) systems, particularly the dominant LCC-HVDC systems. Although grid-flexibility support using LCC-HVDC has been studied, existing methods fail to achieve bidirectional frequency support while maintaining AC voltage. Therefore, a coordinated control method is proposed for the LCC-HVDC system to achieve bilateral frequency support (BFS) and AC voltage regulation (AVR) for asynchronously interconnected systems. The level of frequency support and the coupled dynamics of sending-end (SE) and receiving-end (RE) system frequencies are quantified by the developed low-order frequency response model, different from frequency models in previous research for only one end of the system. With the developed model, the control parameters of the proposed method are analytically calculated. This ensures an appropriate level of primary frequency support without jeopardizing the frequency response of the system at the remote end. The effectiveness of the proposed method is demonstrated through real-time simulation.

24 October 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SLSiqi Lin
Siqi Lin
YXYing Xue
Ying Xue
ZLZhixuan Li
Zhixuan Li
HJHuaiguang Jiang
Huaiguang Jiang
RHRenzong Hu
Renzong Hu
JOJunhui Ou
Junhui Ou
The phase angle jump (PAJ) of the commutation voltage during fault is well-known to have significant impact on the commutation failure during fault recovery (CFFR) in line-commutated converter-based high voltage direct current (LCC-HVDC). However, the value of PAJ has been empirically determined in previous research without a theoretical foundation, leading to inaccurate estimation of its impact on CFFR and inappropriate control actions to mitigate CFFR. To address this issue, this paper theoretically shows how the Network Structure (NS) in different AC systems changes the level of PAJ of commutation voltage, demonstrating the decisive role of changing NS in evaluating CFFR. Specifically, a calculation method based on equivalent AC-DC system (EADSC) is proposed, showing that transient NS changes (TNSC) and transient DC power flow changes (TDPC) jointly contribute to the level of PAJ. Based on these findings, a PAJ-based firing angle compensation strategy (PAJ-ACS) is proposed for CFFR suppression. PAJ-ACS compensates for tracking error of the phase-locked loop (PLL-TE) caused by TNSC and TDPC, and prevents the saturation of the constant extinction angle controller (CEA) by using adaptive extinction angle reference values. Unlike existing methods, PAJ-ACS is designed based on proportional controllers and considers the most extreme PAJ, enabling rapid and targeted compensation with margin, effectively suppressing CFFR under a wide range of fault conditions. The accuracy of the proposed EADSC and the effectiveness of PAJ-ACS are validated using PSCAD/EMTDC simulations on the modified CIGRE LCC-HVDC benchmark system and the IEEE 39-bus system.