Yiping Chen

Yiping Chen

Auto-generated profile, based on publicly available information

Yiping Chen

Power Dispatching and Control Center, China Southern Power Grid, Guangzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YXYing Xue
Ying Xue
YCYiping Chen
Yiping Chen
WZWaisheng Zheng
Waisheng Zheng
YTYuan Tang
Yuan Tang
ZLZhixuan Li
Zhixuan Li
WTWenhu Tang
Wenhu Tang
Power systems worldwide are transforming into renewable-dominated ones that require significant grid flexibility. While extensive research has been done on flexibility from the generation or demand side, there is a significant lack of research on studying flexibility from the grid side. Therefore, this paper proposes a primary frequency response sharing strategy using LCC-HVDC for inverter frequency control. Under an inverter frequency event, the proposed method imposes a controlled load change that is proportional to the inverter AC frequency deviation on the rectifier AC network. This in impact activates the primary frequency response from the rectifier side to support the inverter AC frequency (i.e., sharing of primary frequency response). The level of support and the coupled dynamics of rectifier and inverter frequencies are quantified by the developed mathematical model. The model reveals that the inverter load change is affecting the rectifier AC frequency through two cascaded 2 nd order transfer functions. With the developed model and the desired frequency nadirs at both AC systems, the controller parameters of the proposed method are calculated. This ensures that appropriate level of primary frequency response is shared without jeopardizing the frequency performance of rectifier AC system. The effectiveness of the proposed method is demonstrated using a modified four-generator two-area system. Estimation errors of network inertia and droop constants are discussed.

4 June 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZLZhixuan Li
Zhixuan Li
YXYing Xue
Ying Xue
QFQiang Fu
Qiang Fu
YCYiping Chen
Yiping Chen
WZWaisheng Zheng
Waisheng Zheng
CYConghuang Yang
Conghuang Yang
The Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) system is considered an efficient solution for providing functional support to asynchronously interconnected systems. However, this study demonstrates that frequency support from VSC-HVDC systems can lead to low-frequency power oscillations (LFPOs) due to the interaction between the frequency control and the frequency dynamics of AC grids. For convenience, a practical instance of a 0.25 Hz LFPO observed in the LUXI back-to-back VSC-HVDC project in the China is reported in detail. In this project, the VSC-HVDC system is designed with a frequency control (namely, Co-frequency control) to eliminate frequency divisions between the two asynchronous AC grids under normal operation conditions. Based on the damping torque method, the analysis concludes that the observed LFPO is induced by the interaction between the Co-frequency control and the frequency dynamics of the synchronous generators in AC systems, and is governed by the parameters of the Co-frequency control. To address the LFPO, two damping control schemes are proposed. Finally, all conclusions and findings are validated through EMT simulations. To the best of our knowledge, this is the first report of practical oscillations caused by the frequency control of VSC-HVDC systems, which is meaningful for engineers and researchers, by providing insights about the stable operation of asynchronously interconnected systems.

13 November 2024 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ZLZhixuan Li
Zhixuan Li
YXYing Xue
Ying Xue
YCYiping Chen
Yiping Chen
NCNan Chen
Nan Chen
CYConghuan Yang
Conghuan Yang
JHJiyu Huang
Jiyu Huang
Modern power systems require significant grid flexibility. As the AC transmission lines are passive and cannot be controlled, grid flexibility in the transmission system can only be provided by actively controlling High-Voltage Direct Current (HVDC) systems, particularly the dominant LCC-HVDC systems. Although grid-flexibility support using LCC-HVDC has been studied, existing methods fail to achieve bidirectional frequency support while maintaining AC voltage. Therefore, a coordinated control method is proposed for the LCC-HVDC system to achieve bilateral frequency support (BFS) and AC voltage regulation (AVR) for asynchronously interconnected systems. The level of frequency support and the coupled dynamics of sending-end (SE) and receiving-end (RE) system frequencies are quantified by the developed low-order frequency response model, different from frequency models in previous research for only one end of the system. With the developed model, the control parameters of the proposed method are analytically calculated. This ensures an appropriate level of primary frequency support without jeopardizing the frequency response of the system at the remote end. The effectiveness of the proposed method is demonstrated through real-time simulation.

3 September 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MCMeng Chen
Meng Chen
YXYing Xue
Ying Xue
WZWaisheng Zheng
Waisheng Zheng
YCYiping Chen
Yiping Chen
NCNan Chen
Nan Chen
ZLZhixuan Li
Zhixuan Li
Achieving higher renewable penetration in power systems requires more operational flexibility due to the variability of renewable energy sources. LCC-HVDC systems, boasting the largest installed capacity among existing HVDC technologies, hold tremendous potential to offer grid flexibility through their strong power control capabilities. However, LCC-HVDC systems suffer from the inherent issue of uncontrollability at low power levels, fundamentally limiting their application in providing the much-needed grid flexibility. To address this issue, this paper proposes a new online power reversal strategy for LCC-HVDC based on round power mode (RPM). The proposed strategy can achieve continuous control at low power levels and unlock the full flexibility of LCC-HVDC. Then the detailed modelling of the proposed strategy including power reversal process, mode-switching methods and coordinated operation of bipolar units are presented in this paper. The simulation results using PSCAD/EMTDC demonstrate the performance of the proposed strategy across all power levels.

14 July 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MCMeng Chen
Meng Chen
YXYing Xue
Ying Xue
YCYiping Chen
Yiping Chen
ZLZhixuan Li
Zhixuan Li
SLSiqi Lin
Siqi Lin
GSGoran Strbac
Goran Strbac
Sourcing voltage support from LCC-HVDC is a promising solution for enhancing transmission-level voltage stability. Existing methods contribute to this effort when Thevenin equivalent parameters (TEPs) are available; however, obtaining TEPs requires precise real-time measurements and AC grid modeling. In this paper, an adaptive AC voltage control (A2VC) is proposed to address the challenge of deriving TEPs. Emphasis is put on a linear grid model (LGM) that views the AC grid through a linearized reactive power-AC voltage (Q-V) port characteristic, which results in a locally defined AC grid model that is independent of TEPs. The local LGM is then integrated into the LCC-HVDC control system as an outer loop, enabling the LCC to adjust reactive power in response to AC voltage variations. Compared to existing methods, the proposed method retains simplicity, robustness and adaptability, making it applicable to various grid configurations and conditions. The EMT simulation is used to evaluate the performance of the proposed LGM and A 2VC in both small and large grids. The results reveal a highly linear Q-V characteristic, with the coefficient of determination (R2) exceeding 0.9, as well as a notably reduced AC overvoltage under both reactive disturbances and fault conditions.