To determine the presence of exposure reciprocity in nine resin-based composites (RBCs) using fast (3 s, high irradiance) or standard light-curing modes for 10 s, 20 s, or 30 s. Five sculptable and four flowable bulk-fill RBCs were light-cured using a Bluephase PowerCure light-curing unit (LCU). The RBCs were divided into groups according to the exposure modes tested: fast (3 s mode - at 3130 mW/cm2), or for the manufacturer's recommended time on the standard (High mode at 1226 mW/cm2). The degree of conversion (DC) and reaction rates were measured at 0.2 mm and 4 mm depths for 720 s using real-time spectroscopy. Light transmission (%) was also recorded (n = 3). Parametric or non-parametric 2-way ANOVA was used depending on the data (α=0.05). When compared to the values from the bottom of their 0.2 mm thick value, except for TPFlow-3 s and TPlusFlow-3 s, the bottom of the 4-mm thick specimens had a significantly different DC. Only TPF and TPFlow were statistically the same for both modes at 4 mm; ABF-3 s and OBF-3 s had the lowest DC at the bottom of 4 mm. OBF-3 s had the highest reaction rate at 0.2 mm (61.6 ± 1.2 %/s) while FOBF-10 s had the slowest rate (3.1 ± 0.1 %/s) at the bottom of 4 mm. OBF, BRFlow, TPFlow, TplusFill and TplusFlow had different light transmission patterns than the other RBCs. Depending on the brand of RBC, there was a measurable delay of 0.1 to 2.9 s at the bottom of the RBCs before the polymerization reaction started. Exposure reciprocity does not exist for all RBCs. Depending on the brand of RBC at the bottom of 4 mm there was a measurable delay of 0.1 to 2.9 s before polymerization started. Exposure reciprocity depends on the RBC. Short exposures (3 s) using higher irradiance should only be used when recommended by the manufacturer of the RBC.
24 August 2025 in Journal of Esthetic and Restorative Dentistry
Objective: To determine the effect of differences in the distances and radial positions of the tips of Light‐Curing Units (LCU) on the irradiance values delivered. Materials and Methods: Four LCUs —Valo X, Emitter A, CuringPen , and Pinkwave were tested at different distances from the tip (0, 2, 4, 6, 8 mm) and radial displacements (2 and 4 mm East, West, North, South). The radiant power ( mW ) and emission spectrum ( mW /nm) were measured using an integrating sphere with a 4 mm aperture. Calibrated irradiance beam profiles were recorded across the tip using a laser beam analyzer. Data were analyzed with a two‐way ANOVA at a significance level of 5%. Results: Radial displacement significantly reduced the irradiance values delivered from all four LCUs ( p < 0.05). At 4 mm, the mean irradiance value was below 1000 mW /cm 2 for Emitter A (256 mW/cm 2 ), CuringPen (573 mW/cm 2 ), and Valo X (955 mW/cm 2 ), but not for the Pinkwave (1157 mW /cm 2 ). At the 2 and 4 mm distance from the tip, the Valo X delivered consistent mean irradiance values at both the center and radial positions (2 mm: 1120 mW /cm 2 and 1089 mW /cm 2 ; 4 mm: 979 mW /cm 2 and 945 mW /cm 2 , p > 0.05). The Valo X emitted the most homogeneous beam profile, irrespective of the distance. Conclusion: Variations of 2 or 4 mm in the radial tip position negatively affected irradiance values from the LCUs tested. Clinical Significance: The radial position and LCU choice can significantly affect the irradiance delivered.
1) To investigate two empirical models used to characterize the polymerization kinetics of six resin-based composites (RBCs) and 2) the impact of the sampling rate on the time-varying degree of conversion (DC). The DC of three sculptable and three flowable RBCs was recorded using attenuated total internal reflectance Fourier transform infrared spectroscopy at a collection rate of 13 DC/s. A multiple-diode light-curing unit delivered either an irradiance of 1.2 or 3 W/cm2. The RBC specimens were either 0.2 mm or 4 mm thick and were photocured at 32 ºC. Sampling rates as low as 0.2 DC/s were simulated by numerically interpolating the measured DC(t). The DC(t) obtained at different sampling rates was fitted to the dual-exponential and autocatalytic models. For all six RBCs, the fit of the autocatalytic model to the data resulted in the smallest mean squared errors. The lower simulated sampling rates did not represent the highly time-resolved DC collected at an irradiance of 3 W/cm2 and specimen thickness of 0.2 mm. For the DC simulated at a sampling rate of 0.2 DC/s using PowerFill and analyzed with the autocatalytic model, the maximum DC rate was 3.7 %/s, occurring at a time of 5 s after the start of photocuring. However, using a sampling rate of 13 DC/s, they were 64.5 %/s and 116 ms, respectively. The autocatalytic model was found to better characterize the kinetics of RBC photopolymerization than the dual-exponential model. The data collection rate has a strong influence on the results.
16 February 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Understanding how mechanical damage propagates in load -bearing tissues such as skin, tendons and ligaments, is key to developing regenerative medicine solutions for when these tissues fail. For collagenous tissues in particular, damage is typically assessed after mechanical testing using a broad range of microscopy techniques because standard tensile testing systems do not have the time and force sensitivity to resolve mechanical damage events. Here we introduce an interferometric detection scheme to measure the displacement of a cantilever with a resolution of 0.03% of full scale at a sampling rate of 5000 samples/s. The system is validated using collagen fibers engineered to mimic mammalian tendons. The system can detect sudden decrease in force due to slippage between collagen filaments, one to five microns in diameter, within a fiber in air. It can also detect yield events associated with local collagen unfolding or sliding within collagen fibrils within a fiber in liquid. This is opening the road to the sub -failure study of damage propagation within a broad range of hierarchical biomaterials.
To quantify the degree of conversion (DC), shrinkage strain, shrinkage stress, and polymerization kinetics of ten commercial resin-based composites (RBCs). Ten RBCs were tested. Four rapid-cure Tetric formulations (Tetric plus Fill, PowerFill, Tetric plus Flow, and PowerFlow) were photocured for 3 s at 3.0 W/cm² for DC and strain measurements and the corresponding stress specimens received 2.5 W/cm² for 3 s. Six comparator RBCs were photocured for 10 or 20 s at 1.2 W/cm² in accordance with their manufacturers' instructions. The DC was measured using ATR-FTIR on 0.2-mm-thick specimens for 720 s, whereas axial shrinkage strain and stress were recorded on 1.0-mm-thick specimens for 24 h. Because material and protocol were not varied independently, across-material comparisons were interpreted as intended-use comparisons rather than isolated formulation effects. Tetric plus Fill and Tetric PowerFill produced comparable DC and 24 h shrinkage strain and stress. Among the regular-viscosity RBCs, Admira Fusion x-tra produced the lowest 24 h strain and stress. Tetric PowerFlow produced lower 24 h strain and stress than Tetric plus Flow. The rapid-cure Tetric material/protocol combinations exhibited earlier and larger DC-, strain-, and stress-rate peaks. Estelite Flow had a lower maximum DC rate and a broad, lower strain-rate peak, but it achieved the highest DC at 720 s and had a smaller late-time strain slope. In a regression constrained through the origin, the 24 h shrinkage stress increased with 24 h shrinkage strain under the tensometer geometry and compliance used in this study. The 24 h measurements show that low early shrinkage values may not predict the final material values and ranking.
Dental researchers and manufacturers use the ISO 4049 standard to determine the depth of cure (DoC) of resin-based composites (RBCs). This standard uses a 4 mm diameter stainless-steel mold and subsequently divides the length of the remaining hard RBC by 2. However, the DoC values obtained using this mold have been challenged. Six bulk-fill RBCs (Tetric plus Fill, Tetric plus Flow, Tetric PowerFill, Tetric PowerFlow, Filtek One, and Aura Bulk Fill) were used to investigate the limitations of the 4 mm diameter mold used in the ISO 4049 standard when compared to a 6 mm diameter metal mold that represented the dimensions of a large cavity in a tooth. Two distinct light curing units were used. One light (Elipar S10) emitted a single peak wavelength of light, while the other (Bluephase G4) was a broad-spectrum, multiple-peak curing light. After 10 s of photocuring, the uncured RBC was immediately removed using acetone. The maximum length of the hard RBC remaining was measured and divided by two so that the effect of these two mold diameters on the DoC results could be compared. The DoC of all six RBCs tested was consistently greater in the 6 mm diameter mold (p < 0.0001). Sectioning revealed that the solvent-dissolved specimens had a clear internal boundary between the apparently well-cured RBC and a peripheral, solvent-resistant, “frosty” region. Using a 4 mm diameter stainless-steel mold resulted in a reduced depth of cure values compared to those obtained when the 6 mm diameter mold was used. The use of a broad-spectrum, multiple-peak LED curing light proved unnecessary for photocuring the six RBCs used in this study.