Cristiane Maucoski

Dr. Cristiane Maucoski

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2024 in Dental Materials
Verified
Journal Article
Open access
JGJuliana Anany Gonzales Guarneri
Juliana Anany Gonzales Guarneri
CMCristiane Maucoski
Cristiane Maucoski
SGSeyed Amir Soheil Ghaffari
Seyed Amir Soheil Ghaffari
BMBrett MacNeil
Brett MacNeil
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
This study evaluated the degree of conversion (DC), polymerization kinetics, and temperature of a new self-cure bulk-fill resin-based composite (Stela Automix, SDI). The study was divided into seven groups: (1) Stela Primer, (2) Stela Automix, (3) Stela Automix exposed to light for 20 s after 100 s, (4) Stela Primer with Stela Automix, (5) Stela Primer with Stela Automix and exposed to light for 20 s after 100 s, (6) Scotchbond Universal with Stela Automix, and (7) Scotchbond Universal with Stela Automix and exposed to light for 20 s after 100 s. The real-time reaction rates and DC at the bottom of 2 mm thick specimens at ∼32 °C were measured at 720 s after insertion using a spectrometer with an Attenuated Total Reflectance detector. The temperature of Stela, Stela exposed to light, Stela Primer with Stela, and Stela Primer with Stela exposed to light were measured by an infrared thermal camera in human molar teeth with Class I cavities. The temperature was recorded in real-time every 0.03 s for 720 s. The results were compared with ANOVA and Tukey's multiple comparison test (α = 0.05). The highest degree of conversion (DC) at the 2 mm depth was achieved when Stela Primer was combined with Stela (72.4 ± 3.5 % at 720 s). Stela could self-cure independently, but not as rapidly or effectively as when used with its Primer. The greatest temperature increase was for the light-cured Stela, followed by Stela Primer with Stela RBC exposed to light for 20 s. The Scotchbond Universal bonding system did not significantly increase the DC compared to Stela alone, except when exposed to light for 20 s, which slightly increased the final DC. Exposing Stela to light for 20 s did not improve the final DC of Stela as much as using the Stela Primer, but it did increase the temperature and prolonged the time taken to return to 37 °C. The Stela primer accelerates the degree of conversion of Stela. The reaction occurred rapidly and achieved a higher DC at the bottom of the specimens where the Stela was in contact with the Stela primer. Exposing Stela to light for 20 s is not recommended. Instead, Stela should be used with Stela Primer.

1 January 2019 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
PRPatricio Runnacles
Patricio Runnacles
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
CMCristiane Maucoski
Cristiane Maucoski
UCUlisses Coelho
Ulisses Coelho
MGMario Fernando De Goes
Mario Fernando De Goes
FRFred Rueggeberg
Fred Rueggeberg
Keywords: Bicuspids; Volunteers; Dental curing lights; Temperature

4 February 2023 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
CMCristiane Maucoski
Cristiane Maucoski
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
BSBraden Sullivan
Braden Sullivan
JGJuliana Anany Gonzales Guarneri
Juliana Anany Gonzales Guarneri
BGBruno Gusso
Bruno Gusso
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
Objective: To evaluate the in vitro pulpal temperature rise (ΔT) within the pulp chamber when low‐ and high‐viscosity bulk‐fill resin composites are photo‐cured using laser or contemporary light curing units (LCUs).Materials and Methods: The light output from five LCUs was measured. Non‐retentive Class I and V cavities were prepared in one upper molar. Two T‐type thermocouples were inserted into the pulp chamber. After the PT values reached 32°C under simulated pulp flow (0.026 mL/min), both cavities were restored with: Filtek One Bulk Fill (3 M), Filtek Bulk Fill Flow (3 M), Tetric PowerFill (Ivoclar Vivadent), or Tetric PowerFlow (Ivoclar Vivadent). The tooth was exposed as follows: Monet Laser (1 and 3 s), PowerCure (3 and 20 s), PinkWave (3 and 20 s), Valo X (5 and 20 s) and SmartLite Pro (20 s). The ΔT data were subjected to one‐way ANOVA followed by Scheffe's post hoc test.Results: Monet 1 s (1.9 J) and PinkWave 20 s (30.1 J) delivered the least and the highest amount of energy, respectively. Valo X and PinkWave used for 20 s produced the highest ΔT values (3.4–4.1°C). Monet 1 s, PinkWave 3 s, PowerCure 3 s (except FB‐Flow) and Monet 3 s for FB‐One and TP‐Fill produced the lowest ΔT values (0.9–1.7°C). No significant differences were found among composites.Conclusions: Short 1‐ to 3‐s exposures produced acceptable temperature rises, regardless of the composite.Clinical Significance: The energy delivered to the tooth by the LCUs affects the temperature rise inside the pulp. The short 1–3 s exposure times used in this study delivered the least amount of energy and produced a lower temperature rise. However, the RBC may not have received sufficient energy to be adequately photo‐cured.

1 March 2023 in Dental Materials
Verified
Journal Article
Closed access
CMCristiane Maucoski
Cristiane Maucoski
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
MRMateus Garcia Rocha
Mateus Garcia Rocha
JRJean-François Roulet
Jean-François Roulet
BSBraden Sullivan
Braden Sullivan

10 August 2023 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
CMCristiane Maucoski
Cristiane Maucoski
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
Objective: To evaluate the accuracy of five brands of radiometers in reporting the irradiance (mW/cm2) from twelve brands of LCUs compared to a ‘Gold Standard’ (GS) reference obtained from a hand‐held laboratory‐grade radiometer.Materials and Methods: The irradiance was measured from two examples of twelve brands of previously used LCUs on two examples of five brands of dental radiometers. The emission spectrum was also obtained. Irradiance data from each brand of LCU against each meter was analyzed using the Shapiro–Wilk test for normality. The irradiance values were subjected to a two‐way ANOVA followed by Bonferroni tests for each LCU brand. Finally, a descriptive analysis was made using a 95% confidence interval around the mean irradiance.Results: The power output from the LCUs ranged from 271 mW to 1005 mW. Among the tested radiometers, only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. When measured using the “GS” system, the mean irradiance values from the two examples of nine brands of previously used LCU were not always within ±10% of the irradiance values stated by the manufacturer.Conclusions: The mean irradiance values from 9 of the 12 brands of used LCUs were beyond ±10% of the irradiance values stated by the manufacturer. Only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study.Clinical Significance: There was a wide range in the power output from the LCUs tested. It was impossible to accurately measure the irradiance from all the LCUs using the dental radiometers examined. However, dental radiometers should still be used in dental offices to monitor the light output from LCUs and verify that they are working correctly before they are used on patients.

19 December 2022 in Odontology
Verified
Journal Article
Closed access
PDF file
CMCristiane Maucoski
Cristiane Maucoski
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
BSBraden Sullivan
Braden Sullivan