The adhesion of endodontic sealers to dentin may be influenced both by the chemical composition of the sealer and the final irrigation protocol. The aim of this study was to examine the push-out bond strength of three differently formulated bioceramic sealers to root canal dentin, after different irrigation protocols. Four cavities were prepared in dentine discs obtained from middle thirds of third molars with fused roots. Discs were randomly divided into three groups (n = 8). Group 1: specimens were immersed in 2.5% NaOCl; group 2: in 2.5% NaOCl followed by 17% EDTA; and group 3: in a solution of 2.5% NaOCl with 9% etidronic acid (HEDP). The cavities on each disk were filled with four tested sealers: AH Plus Bioceramic, Bio C Angelus, BioRoot RCS, and AH Plus (n = 8 per sealer). The push-out bond strength test was performed after 7 days. The data were statistically analyzed using two-way analysis of variance with the Bonferroni post hoc test (α = 0.05). Irrigation with NaOCl resulted in significantly lower bond strength values of the sealers in comparison to NaOCl/EDTA and NaOCl/HEDP groups. In the NaOCl and NaOCl/HEDP groups, BioRoot RCS showed similar push-out bond strength compared to AH Plus and significantly higher compared to Bio-C and AH Plus Bioceramic. In the NaOCl/EDTA group, bioceramic sealers achieved a significantly weaker bond strength compared to AH Plus. The bond strength of BioRoot RCS was significantly higher compared to Bio-C and AH Plus Bioceramic. The irrigation protocols and the chemical composition of the sealers significantly influenced their bond strength to dentin. Epoxy resin-based sealer achieved the strongest bond strength, while within bioceramic sealers, the highest values were obtained for BioRoot RCS and the lowest for AH Plus Bioceramic.
The calcium silicate-based sealers currently available on the market have different compositions and formulations, which is why their physical and chemical properties may vary. (1) The aim of the study was to measure the physico-chemical properties of calcium silicate-based sealers and their push-out bond strength to root dentine, comparing two push-out testing protocols. (2) Standardized specimens of EndoSequence BC, BioRoot RCS, MTA Fillapex, and AH Plus (control) were subjected to pH measurements over 28 days. Radiopacity was measured using a CCD sensor, and flexural strength was assessed using a three-point bending setup. Push-out bond strength was measured in coronal, middle, and apical sections of 40 single-root teeth (conventional method), and cylindrical cavities were prepared for all sealers on the same root dentine disks in 11 third molars (disk method). (3) EndoSequence BC exhibited a higher pH than MTA Fillapex and the highest radiopacity (p < 0.05). The highest flexural and push-out bond strengths were found for AH Plus. The push-out bond strength of EndoSequence BC and BioRoot RCS was higher than MTA Fillapex (p < 0.05). The conventional and disk methods exhibited similar push-out bond strength results, but the data were more homogeneously distributed in the disk method. (4) All calcium silicate-based sealers exhibited a higher pH than AH Plus. MTA Fillapex did not meet the ISO standard. Calcium silicate-based sealers showed weaker performance in terms of physical properties compared to AH Plus.
13 October 2018 in Engineering, Technology & Applied Science Research
This paper describes one new approach to frequency locked loop (FLL), which is based on the time non-recursive processing of input periods. System parameters are defined by the ratio of frequencies. The conditions, under which the described system can have the properties of a FLL, are analyzed. All math analyses were made by the use of Z transform approach. It was shown that FLL is extremely fast and that it is suitable for usage in different predicting, tracking and modulation applications, for the measurements of frequency and for other applications. The FLL realization in the technique of standard integrated circuits is described. The oscilloscope picture, made on the realized 8 bit model, is presented. Analysis in frequency domain was made using Matlab tools.
Introduction. Marginal seal or adequate marginal adaptation of material along the cavity walls should be able to prevent leakage of tissue fluid and consequently bacterial microleakage, terefore, it is considered as significant factor for long term success of endodontic treatment. The aim of this work was to test the marginal microleakage of newly synthesized nanostructured biomaterials based on calcium aluminate, calcium silicate and MTA with a dye penetration test after application the material to the interradicular perforations of extracted teeth. Material and method. The study included 48 extracted human maxillary and mandibular molars. Newly synthesized nanostructured materials were tested: material based on calcium aluminate, calcium silicate. Commercial calcium silicate cement (MTA Angelus, Londrina, Brazil) was used as a control material. Marginal microleakage was examined with a dye penetration test six months after application of the material in experimentally prepared interradicular perforations on extracted human molars. Penetration depth measurement was analyzed with a binocular magnifier (Leica DM 500, Leica Byosistems). Results are expressed in millimeters and statistically processed by applying the analysis of variance for repeated measurements with the Sidak test. Results. The lowest average penetration (mm) was for MTA (1.40 ? 0.63 mm), and the highest for Ca aluminates (2.10 ? 0.63 mm), while for calcium silicates an average color penetration of 1.73 ? 0, 67mm was recorded. By testing intergroup differences in color penetration between groups, a statistically significant difference between MTA and Ca aluminate was obtained using Sidak?s test (t = -0.693; p = 0.036). No statistically significant difference was recorded between MTA and Ca silicate, nor was there a statistically significant difference between Ca aluminate and Ca silicate. Conclusion. The lowest marginal microleakage, the best marginal sealing, was recorded with the MTA material. The microleakage of calcium aluminate-based materials was significantly higher compared to calcium silicate and MTA.
Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files.
1 January 2023 in Srpski arhiv za celokupno lekarstvo
Glide path is a procedure that precedes mechanical instrumentation of the root canals. It is defined as a procedure used to expand or create a smooth tunnel from the coronal part of the root canal to its physiological terminus. It is performed using small sized hand files or specially designed mechanical NiTi instruments. An adequately created glide path extends the life of rotary NiTi instruments, enables better mechanical and chemical debridement and easier preservation of original morphology of endodontic space during further mechanical instrumentation. Frequent use of mechanical instrumentation in daily practice requires better understanding of glide path, its significance, and instruments and techniques used for its creation.