European energy policies introduced nearly zero energy building (NZEB) design to stimulate the energy transition in buildings, and EU programmes promote the evolution towards positive energy buildings (PEB). Most studies into NZEBs are based on simulations, and not on real monitoring data. This paper presents the real performance data of the Zero building, an NZEB office building with Leed Gold and Breeam Excellent environmental design certifications located in a neighbourhood that shares a zero-emission district heating–cooling facility relying only on 100% renewable energy sources. The current performance of the building and its neighbourhood is assessed to identify the existing gap to reach the goals of positive energy buildings (PEB). A study showed that it achieved a degree of self-sufficiency of 74.3% for the operational electric energy and that its carbon footprint is only 3.35 kgCO2/m2y, 92% lower than in a typical office building in locations with the same climate. GRAPHICAL ABSTRACT
This paper analyses the current definition of positive energy building (PEB) and a selection of both NZEB and PEB built projects with real monitored data, discussing their design features and potential for achieving positive energy balance. The research aims to assess an optimal ratio between photovoltaic (PV) area and achieved self-sufficiency ratios in office buildings. The study shows that most of the buildings’ PV systems have an area equal to 10–20% of the total building’s net floor area. Buildings that have PV to area ratio from 13% to 20% are self-sufficient from 100% to 150%. PV installation in the façades results decisive for reaching positive energy balance. The relation of the PV system installed on the façade to PV system on the roof is from 50% to 57% for the studied buildings. Buildings located in sites with higher global horizontal irradiation (GHI) tend to have lower PV area ratios.
Good indoor comfort and air quality are essential for correct educational development. Most reports in this field focus on primary and secondary school buildings, with numerous projects conducted in the Mediterranean Zone. However, little has been done in the context of university buildings. Data on indoor temperature and relative humidity data acquired trough field surveys of a seminar room located in the Architecture Faculty in San Sebastian (Spain) is provided in this paper. The seminar room was monitored during a typical spring week. The data presented in the article are related to the research article entitled Retrofit strategies towards Net Zero Energy Educational Buildings: a case study at the University of the Basque Country (Ref. 0378-7788).