Olatz Irulegi Garmendia

Prof. Dr. Olatz Irulegi Garmendia

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Energy and Buildings
Verified
Journal Article
Closed access
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
ÁRÁlvaro Ruíz-Pardo
Álvaro Ruíz-Pardo
ASAntonio Serra
Antonio Serra
JLJosé Manuel Salmerón Lissen
José Manuel Salmerón Lissen
RVR. Vega
R. Vega

1 September 2021 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Open access
LCLaura Carlosena
Laura Carlosena
ÁAÁngel Andueza
Ángel Andueza
LTLuis Torres
Luis Torres
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
Mst SantamourisMst Santamouris
Mst Santamouris

1 November 2014 in Energy and Buildings
Verified
Journal Article
Closed access
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
LTL. Torres
L. Torres
ASAntonio Serra
Antonio Serra
IMI. Mendizabal
I. Mendizabal
RHR. Hernández
R. Hernández

21 September 2021 in Architectural Science Review
Verified
Journal Article
Closed access
XBX. Barrutieta
X. Barrutieta
JGJoseba Gainza-Barrencua
Joseba Gainza-Barrencua
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
European energy policies introduced nearly zero energy building (NZEB) design to stimulate the energy transition in buildings, and EU programmes promote the evolution towards positive energy buildings (PEB). Most studies into NZEBs are based on simulations, and not on real monitoring data. This paper presents the real performance data of the Zero building, an NZEB office building with Leed Gold and Breeam Excellent environmental design certifications located in a neighbourhood that shares a zero-emission district heating–cooling facility relying only on 100% renewable energy sources. The current performance of the building and its neighbourhood is assessed to identify the existing gap to reach the goals of positive energy buildings (PEB). A study showed that it achieved a degree of self-sufficiency of 74.3% for the operational electric energy and that its carbon footprint is only 3.35 kgCO2/m2y, 92% lower than in a typical office building in locations with the same climate. GRAPHICAL ABSTRACT

20 October 2022 in Architectural Science Review
Verified
Journal Article
Closed access
XBX. Barrutieta
X. Barrutieta
AKA. Kolbasnikova
A. Kolbasnikova
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
This paper analyses the current definition of positive energy building (PEB) and a selection of both NZEB and PEB built projects with real monitored data, discussing their design features and potential for achieving positive energy balance. The research aims to assess an optimal ratio between photovoltaic (PV) area and achieved self-sufficiency ratios in office buildings. The study shows that most of the buildings’ PV systems have an area equal to 10–20% of the total building’s net floor area. Buildings that have PV to area ratio from 13% to 20% are self-sufficient from 100% to 150%. PV installation in the façades results decisive for reaching positive energy balance. The relation of the PV system installed on the façade to PV system on the roof is from 50% to 57% for the studied buildings. Buildings located in sites with higher global horizontal irradiation (GHI) tend to have lower PV area ratios.

1 August 2017 in Data in Brief
Verified
Journal Article
Open access
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
ASAntonio Serra
Antonio Serra
RHR. Hernández
R. Hernández
Good indoor comfort and air quality are essential for correct educational development. Most reports in this field focus on primary and secondary school buildings, with numerous projects conducted in the Mediterranean Zone. However, little has been done in the context of university buildings. Data on indoor temperature and relative humidity data acquired trough field surveys of a seminar room located in the Architecture Faculty in San Sebastian (Spain) is provided in this paper. The seminar room was monitored during a typical spring week. The data presented in the article are related to the research article entitled Retrofit strategies towards Net Zero Energy Educational Buildings: a case study at the University of the Basque Country (Ref. 0378-7788).