Laura Carlosena

Dr. Laura Carlosena

Universidad Publica de Navarra, Pamplona, Navarre, Spain
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Solar Energy
Verified
Journal Article
Closed access
LCLaura Carlosena
Laura Carlosena
ÁRÁlvaro Ruíz-Pardo
Álvaro Ruíz-Pardo
JFJie Feng
Jie Feng
OIOlatz Irulegi
Olatz Irulegi
RHRufino J. Hernández-Minguillón
Rufino J. Hernández-Minguillón
MSMattheos Santamouris
Mattheos Santamouris

1 September 2021 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Open access
LCLaura Carlosena
Laura Carlosena
ÁAÁngel Andueza
Ángel Andueza
LTLuis Torres
Luis Torres
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
Mst SantamourisMst Santamouris
Mst Santamouris

4 August 2023 in Computational Urban Science
Verified
Journal Article
Open access
PDF file
AKAnsar Khan
Ansar Khan
LCLaura Carlosena
Laura Carlosena
SKSamiran Khorat
Samiran Khorat
RKRupali Khatun
Rupali Khatun
DDDebashish Das
Debashish Das
DNDev Niyogi
Dev Niyogi
Cool materials and rooftop vegetation help achieve urban heating mitigation as they can reduce building cooling demands. This study assesses the cooling potential of different mitigation technologies using Weather Research and Forecasting (WRF)- taking case of a tropical coastal climate in the Kolkata Metropolitan Area. The model was validated using data from six meteorological sites. The cooling potential of eight mitigation scenarios was evaluated for: three cool roofs, four green roofs, and their combination (cool-city). The sensible heat, latent heat, heat storage, 2-m ambient temperature, surface temperature, air temperature, roof temperature, and urban canopy temperature was calculated. The effects on the urban boundary layer were also investigated.The different scenarios reduced the daytime temperature of various urban components, and the effect varied nearly linearly with increasing albedo and green roof fractions. For example, the maximum ambient temperature decreased by 3.6 °C, 0.9 °C, and 1.4 °C for a cool roof with 85% albedo, 100% rooftop vegetation, and their combination.The cost of different mitigation scenarios was assumed to depend on the construction options, location, and market prices. The potential for price per square meter and corresponding temperature decreased was related to one another. Recognizing the complex relationship between scenarios and construction options, the reduction in the maximum and minimum temperature across different cool and green roof cases were used for developing the cost estimates. This estimate thus attempted a summary of the price per degree of cooling for the different potential technologies.Higher green fraction, cool materials, and their combination generally reduced winds and enhanced buoyancy. The surface changes alter the lower atmospheric dynamics such as low-level vertical mixing and a shallower boundary layer and weakened horizontal convective rolls during afternoon hours. Although cool materials offer the highest temperature reductions, the cooling resulting from its combination and a green roof strategy could mitigate or reverse the summertime heat island effect. The results highlight the possibilities for heat mitigation and offer insight into the different strategies and costs for mitigating the urban heating and cooling demands.

19 January 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
AKAnsar Khan
Ansar Khan
LCLaura Carlosena
Laura Carlosena
JFJIE FENG
JIE FENG
SKSamiran Khorat
Samiran Khorat
RKRupali Khatun
Rupali Khatun
Mst SantamourisMst Santamouris
Mst Santamouris
Broadband passive daytime radiative cooling (PDRC) materials exhibit sub-ambient surface temperatures and contribute highly to mitigating extreme urban heat during the warm period. However, their application may cause undesired overcooling problems in winter. This study aims to assess, on a city scale, different solutions to overcome the winter overcooling penalty derived from using PDRC materials. Furthermore, a mesoscale urban modeling system assesses the potential of the optical modulation of reflectance (ρ) and emissivity (ε) to reduce, minimize, or reverse the overcooling penalty. The alteration of heat flux components, air temperature modification, ground and roof surface temperature, and the urban canopy temperature are assessed. The maximum decrease of the winter ambient temperature using standard PDRC materials is 1.1 °C and 0.8 °C for daytime and nighttime, respectively, while the ρ+ε-modulation can increase the ambient temperature up to 0.4 °C and 1.4 °C, respectively, compared to the use of conventional materials. Compared with the control case, the maximum decrease of net radiation inflow occurred at the peak hour, reducing by 192.7 Wm−2 for the PDRC materials, 5.4 Wm−2 for ρ-modulated PDRC materials, and 173.7 Wm−2 for ε-PDRC materials; nevertheless, the ρ+ε-modulated PDRC materials increased the maximum net radiation inflow by 51.5 Wm−2, leading to heating of the cities during the winter.

5 August 2023 in Building and Environment
Verified
Journal Article
Open access
LCLaura Carlosena
Laura Carlosena
ÁRÁlvaro Ruiz-Pardo
Álvaro Ruiz-Pardo
EREnrique Ángel Rodríguez-Jara
Enrique Ángel Rodríguez-Jara
MSMattheos Santamouris
Mattheos Santamouris

1 January 2021 in Solar Energy Advances
Verified
Journal Article
Open access
AKAnsar Khan
Ansar Khan
LCLaura Carlosena
Laura Carlosena
SKSamiran Khorat
Samiran Khorat
RKRupali Khatun
Rupali Khatun
QDQuang-Van Doan
Quang-Van Doan
MSMattheos Santamouris
Mattheos Santamouris