Rufino Hernandez

Prof. Rufino Hernandez

University of the Basque Country
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Open access
LCLaura Carlosena
Laura Carlosena
ÁAÁngel Andueza
Ángel Andueza
LTLuis Torres
Luis Torres
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
Mst SantamourisMst Santamouris
Mst Santamouris

20 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Alexander Martín-GarínAlexander Martín-Garín
Alexander Martín-Garín
JMJosé Antonio Millán-García
José Antonio Millán-García
Juan Maria Hidalgo-BetanzosJuan Maria Hidalgo-Betanzos
Juan Maria Hidalgo-Betanzos
RHRufino Hernandez
Rufino Hernandez
ABAbderrahmane Baïri
Abderrahmane Baïri
Airtightness is a major issue in architectural design and it has a significant impact on the energy performance of buildings. Moreover, the energy behaviour of built heritage is due, to its singular characteristics, still a great unknown. The aim of this study is to establish a better knowledge of the airtightness of historical buildings, based on an in depth field study using blower-door tests. A set of 37 enclosures were analyzed inside eight buildings located in historical areas of a Spanish city with a significant built heritage. They were constructed between 1882 and 1919 and include diverse construction typologies applied for many building uses such as residential, cultural, educational, administrative and emblematic. The results indicate lower values compared to other previous airtightness studies of historical buildings. The average air change rate was found to be n50 = 9.03 h−1 and the airtightness of the enclosures presented a wide range of between 0.68 and 37.12 h−1. Three main levels of airtightness were identified with two thirds of the tested samples belonging to the intermediate level between 3–20 h−1. To conclude, several correlations have been developed which provide a method to estimate air leakage and could serve as a basis for energy performance studies of these kinds of building.

21 September 2021 in Architectural Science Review
Verified
Journal Article
Closed access
XBX. Barrutieta
X. Barrutieta
JGJoseba Gainza-Barrencua
Joseba Gainza-Barrencua
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
European energy policies introduced nearly zero energy building (NZEB) design to stimulate the energy transition in buildings, and EU programmes promote the evolution towards positive energy buildings (PEB). Most studies into NZEBs are based on simulations, and not on real monitoring data. This paper presents the real performance data of the Zero building, an NZEB office building with Leed Gold and Breeam Excellent environmental design certifications located in a neighbourhood that shares a zero-emission district heating–cooling facility relying only on 100% renewable energy sources. The current performance of the building and its neighbourhood is assessed to identify the existing gap to reach the goals of positive energy buildings (PEB). A study showed that it achieved a degree of self-sufficiency of 74.3% for the operational electric energy and that its carbon footprint is only 3.35 kgCO2/m2y, 92% lower than in a typical office building in locations with the same climate. GRAPHICAL ABSTRACT

19 July 2022 in Buildings
Verified
Journal Article
Open access
JOJorge Otaegi
Jorge Otaegi
RHRufino Hernandez
Rufino Hernandez
Xabat OregiXabat Oregi
Xabat Oregi
Alexander Martín-GarínAlexander Martín-Garín
Alexander Martín-Garín
IVIÑIGO RODRIGUEZ VIDAL
IÑIGO RODRIGUEZ VIDAL
In the last decade, several European directives have been established to contribute to the 2020, 2030 and 2050 energy saving targets and impose energy efficiency requirements for new construction, existing buildings and building renovation operations. One of the ways to achieve said objectives is to rely on the most demanding energy efficiency labels existing in Europe, such as Passivhaus, and to implement similar concepts into the national energy regulations of European countries based on a high-performance thermal envelope (high insulation and high-performance windows), high airtightness and high-performance heat-recovery ventilation systems, and solar heat harvesting. This energy conservation concept has shown to be effective for houses with low-density occupation in cold climates, but may cause severe overheating problems in denser collective housing in temperate and hot climates with higher solar radiation. To assess this impact, five flats in three developments from different periods that range from no insulation at all to a nZEB, Passivhaus-certified high-rise are compared in this paper, using data from a monitoring campaign during the summer of 2020. The results show and quantify the strong impact the evolution of the energy saving regulatory trend has had on summer indoor comfort, which may in some cases lead to previously unnecessary air conditioning for cooling and, ultimately, be counterproductive towards the end goals of reducing energy consumption and greenhouse-effect gas emissions and mitigating climate change.

20 October 2022 in Architectural Science Review
Verified
Journal Article
Closed access
XBX. Barrutieta
X. Barrutieta
AKA. Kolbasnikova
A. Kolbasnikova
OGOlatz Irulegi Garmendia
Olatz Irulegi Garmendia
RHRufino Hernandez
Rufino Hernandez
This paper analyses the current definition of positive energy building (PEB) and a selection of both NZEB and PEB built projects with real monitored data, discussing their design features and potential for achieving positive energy balance. The research aims to assess an optimal ratio between photovoltaic (PV) area and achieved self-sufficiency ratios in office buildings. The study shows that most of the buildings’ PV systems have an area equal to 10–20% of the total building’s net floor area. Buildings that have PV to area ratio from 13% to 20% are self-sufficient from 100% to 150%. PV installation in the façades results decisive for reaching positive energy balance. The relation of the PV system installed on the façade to PV system on the roof is from 50% to 57% for the studied buildings. Buildings located in sites with higher global horizontal irradiation (GHI) tend to have lower PV area ratios.

31 December 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
AEArritokieta Eizaguirre-Iribar
Arritokieta Eizaguirre-Iribar
OGOlatz Grijalba
Olatz Grijalba
RHRufino Hernandez
Rufino Hernandez
The disappearance of kilometers of railways that once structured their surrounding territory has become an alarming issue in the last decades. These days, several disused railway infrastructures have been converted into non-motorized transport infrastructures. Meanwhile, most of the railway nodes have been abandoned or reused without consideration of the linear infrastructure. This paper argues that former railway nodes can have potential in their surrounding environment and as part of a non-motorized transport axis, i.e., to again be nodes of the former linear infrastructure. Accordingly, the objective of the paper is to analyze the potential of disused railway nodes, focusing on the possibilities they could offer in the area, and defining future approaches for more sustainable development. For that purpose, relations between former railway nodes and their surrounding environment are studied considering transport and land use in the non-motorized influence areas. Existing node/place models were adapted and a multiaxial model was created to measure the balance between transport and land use and typify the defined area. The proposed methodology was applied in a case study, classifying node areas in different development typologies that will be related to different future approaches.