Jorge De León-Ruiz

Dr. Jorge De León-Ruiz


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
JLJorge De León-Ruiz
Jorge De León-Ruiz
Ignacio Carvajal-MariscalIgnacio Carvajal-Mariscal
Ignacio Carvajal-Mariscal
An analytical model is proposed to evaluate the performance of a Direct Expansion Solar-Assisted Heat Pump under a given environmental condition. These thermal machines commonly employ uncovered flat plate solar collectors, and given this, the convection phenomenon is taken into account as well as the effect of the diffuse and reflected solar radiation in addition to the normal beam radiation absorbed by the tilted surface of the collectors. The heat pump cycle is modelled through a first law of thermodynamics approach in order to compute the heat yielded through condensation and the minimum heat required by the volume of water in the thermal storage unit. Consequently, the thermal capacity of the heat pump, the ratio at which the system yields heat to a given load of water, is calculated and discussed. The results of the model proposed are compared with the experimental data provided by three research papers with experiments conducted in different geographic coordinates and test rigs operating during diverse atmospheric conditions. A maximum relative error of 20% was obtained and furthermore, a statistical analysis of the data was conducted having found that there is no significant statistical difference between the analytical and experimental data samples within the 95% confidence interval. Finally, based on the thermal capacity, the performance of the heat pump is evaluated and a multi-objective optimization technique is implemented to obtain the best possible combination of factors to further enhance the performance of the heat pump.

7 March 2024 in Fluids
Verified
Journal Article
Open access
PDF file
MCMauricio De la Cruz-Ávila
Mauricio De la Cruz-Ávila
JLJorge De León-Ruiz
Jorge De León-Ruiz
Ignacio Carvajal-MariscalIgnacio Carvajal-Mariscal
Ignacio Carvajal-Mariscal
JKJaime Klapp
Jaime Klapp
This study investigates cavitation in a rectangular-profile Venturi tube using numerical simulations and four turbulence models. The unsteady Reynolds-averaged Navier–Stokes technique is employed to simulate vapor cloud formation and compared against experimental data. κ-ε realizable, κ-ε RNG, κ-ω SST, and κ-ω GEKO models are evaluated. The simulation results are analyzed for pressure, turbulence, and vapor cloud formation. Discrepancies in cavitation cloud formation among turbulence models are attributed to turbulence and vapor cloud interactions. RNG and SST models exhibit closer alignment with the experimental data, with RNG showing a superior performance. Key findings include significant vapor cloud shape differences across turbulence models. The RNG model best predicts velocity at the throat exit with an error of 4.145%. Static pressure predictions include an error of 4.47%. The vapor cloud length predictions show variation among models, with the RNG model having a 0.386% error for the minimum length and 4.9845% for the maximum length. The SST model exhibits 4.907% and 13.33% errors for minimum and maximum lengths, respectively. Analysis of the cavitation number reveals agreement with the experimental data and sensitivity to cavitation onset. Different turbulence models yield diverse cloud shapes and detachment points. Weber number contours illustrate the variation in the cavitation cloud behavior under different turbulence models.

16 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
Ignacio Carvajal-MariscalIgnacio Carvajal-Mariscal
Ignacio Carvajal-Mariscal
JLJorge De León-Ruiz
Jorge De León-Ruiz
JVJorge Vazquez-Arenas
Jorge Vazquez-Arenas
Maria VenegasMaria Venegas
Maria Venegas
An experimental study is presented to account for the implementation of a two-phase closed thermosyphon pipe, for energy-saving purposes, in air conditioning systems in the context of COVID-19. The experimental setup consisted of a 0.5 m × 0.0127 m type L copper pipe which was employed as the body of the heat exchanger; an electric resistance heater of 0.1 m length located at the bottom; and a 0.25 m length water-cooled concentric condenser located at the top. The evaluation was conducted employing acetone, ethanol, and distilled water as working fluids; ranging the heat supplied at the evaporator from 25 to 125 W and the filling ratio from 20% to 40% of the total inner volume of the thermosyphon. From the data obtained, it was found that ethanol is the working fluid most susceptible to changes in operation conditions. Contrarily, distilled water was found to deliver consistent performance, up to a point that, for the analysed setup, it is considered to be independent of both, heat flow supplied at the evaporator and thermosyphon filling ratio. Meanwhile, acetone was found to be the only fluid tested that displays a directly proportional behaviour between heat absorption and dissipation. From compiling experimental data, response surfaces were constructed and used as direct and rough optimization tools. The information provided by this approach is considered to be particularly useful and is introduced for modelling and design purposes. Based on the results, it was found that acetone, within operation ranges of 34%<ϕ<40% and 75 W<Q˙Evap<125 W, was the most suitable working fluid to use in a two-phase closed thermosyphon for energy-saving purposes in air conditioning applications.


25 April 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
JLJorge De León-Ruiz
Jorge De León-Ruiz
Ignacio Carvajal-MariscalIgnacio Carvajal-Mariscal
Ignacio Carvajal-Mariscal
MCMauricio De la Cruz-Ávila
Mauricio De la Cruz-Ávila
JKJaime Klapp
Jaime Klapp
EVEnrique Vázquez
Enrique Vázquez
A computationally-supported experimental technique is presented, to measure height of luminous flames, using convolution and density-based spatial clustering for image processing. The experimental setup employs a high-definition camera array to capture flame imagery from 0°, 45° and 90° visualization planes. The volumetric fuel flow was ranged from 350 to 1800 cc min −1 and images of the resulting flame structure were captured and measured. Results show that output measurements are affected by both the volumetric fuel flow and the visualization plane. Whilst the former is evidently the most significant factor, the latter was found to be relevant, since several flame features, particularly, flame tilt and flickering, are only perceivable through specific visualization planes; attributed to uneven flame structure due non-homogeneous thermal stress. The experimental technique proposed yields an overall statistical tolerance of 1.29 cm and an expanded uncertainty of 0.609 cm (∼11.5%). From these results, the test is considered successful and the proposed experimental technique is deemed to be on par with the already existing ones. The utilization of spatial density clustering of image gridded data has only been tested for this implementation; being severely constrained by the sample size and density variability of the data. Consequently, care should be exercised. Nonetheless, this approach was found to inherently recognize flame front edge, and mitigate variations of pixel value due change in flame intensity, normalizing image processing, hence, it is proposed as a viable alternative for flame feature/structure visualization and estimation, and further research is encouraged.

14 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
JLJorge De León-Ruiz
Jorge De León-Ruiz
Ignacio Carvajal-MariscalIgnacio Carvajal-Mariscal
Ignacio Carvajal-Mariscal
APAntonin Ponsich
Antonin Ponsich
The present work conducts an evaluation of the feasibility and the overall performance and consequent optimization of a direct expansion solar assisted heat pump (DXSAHP) employed for domestic water heating. For the study conducted R134a, R404A, R407C and R410A working fluids were evaluated as well as the use of four, six and eight flat-plate solar collectors and a worktime ranging from 1 to 6 h. The case study is based in Mexico City with a 300 L container and a hot water outlet temperature of 51 °C. The paper introduces a new evaluation criterion based on the thermal capacity and all the evaluations conducted throughout this research revolve around this performance metric. The results show that, the system would require at least 4 h of operation to achieve the outlet temperature. Additionally, it was found that the R410A refrigerant has the best heat transfer properties; with an average condensation heat rate of 6.31 kW, followed by the R407C with 5.72 kW, the R404A with 5.42 kW and the R134a with 5.18 kW. Diversely, the R134a refrigerant requires 0.402 kW of compression work, 62% less than the R410A, which requires 1.06 kW. Consequently, R134a delivers the highest COP, which ranges from 7 to 14, followed by the R407C and R404A refrigerants, which present a similar behaviour between them, with COP ranging from 5 to 9 and 4 to 8, respectively, and finally the R410A, achieving the lowest COP, ranging from 3.5 to 6.5. Moreover, it was found that the R134a presents a higher dispersion regarding the energy exchange rate, which reveals that it is the fluid most susceptible to external factors, such as the weather. Contrarily, the remaining refrigerants present a more consistent performance. Finally, the optimization revealed that the R407C refrigerant is the most suitable given that it requires 20% less compression work than the R404A. This provides the heat pump system with a steadier behaviour, a COP ranging from 7 to 8, 30% higher than R410A, a worktime decrease of 1.5 h and heat transfer area of 5.5 flat-plate solar collectors, equivalent to a 31% reduction, both compared to R134a.