Alexandre De Moraes Filho

Mr. Alexandre De Moraes Filho


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
AFAlexandre De Moraes Filho
Alexandre De Moraes Filho
PGPedro M. Gewehr
Pedro M. Gewehr
JMJoaquim Miguel Maia
Joaquim Miguel Maia
DJDouglas R. Jakubiak
Douglas R. Jakubiak
This paper presents a gaseous oxygen detection system based on time-resolved phosphorimetry (time-domain), which is used to investigate O2 optical transducers. The primary sensing elements were formed by incorporating iridium(III) and palladium(II) meso-tetrakis(pentafluorophenyl)porphyrin complexes (IrTFPP-CO-Cl and PdTFPP) in polystyrene (PS) solid matrices. Probe excitation was obtained using a violet light-emitting diode (LED) (low power), and the resulting phosphorescence was detected by a high-sensitivity compact photomultiplier tube. The detection system performance and the preparation of the transducers are presented along with their optical properties, phosphorescence lifetimes, calibration curves and photostability. The developed lifetime measuring system showed a good signal-to-noise ratio, and reliable results were obtained from the optodes, even when exposed to moderate levels of O2. The new IrTFPP-CO-Cl membranes exhibited room temperature phosphorescence and moderate sensitivity: <τ0>/<τ21%> ratio of ≈6. A typically high degree of dynamic phosphorescence quenching was observed for the traditional indicator PdTFPP: <τ0>/<τ21%> ratio of ≈36. Pulsed-source time-resolved phosphorimetry combined with a high-sensitivity photodetector can offer potential advantages such as: (i) major dynamic range, (ii) extended temporal resolution (Δτ/Δ[O2]) and (iii) high operational stability. IrTFPP-CO-Cl immobilized in polystyrene is a promising alternative for O2 detection, offering adequate photostability and potentially mid-range sensitivity over Pt(II) and Pd(II) metalloporphyrins.

1 January 2021 in Procedings Do Xv Simpósio Brasileiro de Automação Inteligente
Verified
Conference Paper
Open access
PDF file
AMAndré N. Makoski
André N. Makoski
AFAlexandre De Moraes Filho
Alexandre De Moraes Filho
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
Identificar defeitos assim que eles ocorram é uma estratégia essencial para garantia da qualidade dos produtos e para evitar perdas no processo produtivo. A identificação de defeitos na fonte ao invés da detecção após o valor adicional ter sido agregado tem crescido na indústria recentemente, especialmente com o avanço da tecnologia no contexto da Indústria 4.0. Este artigo visa especificamente desenvolver uma solução error proofing utilizando o framework DMAIC como processo de melhoria e o FMEA como ferramenta de engenharia. Após utilizar o framework para mapear o processo, foi escolhido um modo de falha para correção através de um sistema de visão. Os resultados gerados por esse experimento se mostraram satisfatório. O modelo proposto poderá ser explorado por profissionais e estudantes que buscam identificar perdas e elimina-las nos processos de negócios