Gutowska Agnieszka

Dr. Gutowska Agnieszka


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Polymers
Verified
Journal Article
Open access
PDF file
Michał PuchalskiMichał Puchalski
Michał Puchalski
GSGrzegorz Szparaga
Grzegorz Szparaga
BTBiela Tadeusz
Biela Tadeusz
GAGutowska Agnieszka
Gutowska Agnieszka
SSSławomir Sztajnowski
Sławomir Sztajnowski
Izabella KrucińskaIzabella Krucińska
Izabella Krucińska
In this paper, the influence of the various degradation conditions, on the molecular and supramolecular structure of polybutylene succinate (PBS) and polybutylene succinate adipate (PBSA) copolymer during degradation is described. The experiment was carried out by the use of injection molded samples and normalized conditions of biodegradation in soil, composting and artificial weathering. Materials were studied by size-exclusion chromatography (SEC) coupled with multiangle laser light scattering (MALLS) detection and wide-angle X-ray diffraction (WAXD). Additionally, the physical and mechanical properties of the samples were determined. The performed experiments clearly show difference impacts of the selected degradation conditions on the macroscopic, supramolecular and molecular parameters of the studied aliphatic polyesters. The structural changes in PBS and PBSA explain the observed changes in the physical and mechanical properties of the obtained injection molded samples.

5 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
BŻBogusława Żywicka
Bogusława Żywicka
MSMarcin H. Struszczyk
Marcin H. Struszczyk
DPDanuta Paluch
Danuta Paluch
KKKrzysztof Kostanek
Krzysztof Kostanek
IKIzabella Krucińska
Izabella Krucińska
PKPaweł Kubiak
Paweł Kubiak
A knitted implant, unilaterally modified with plasma-assisted chemical-vapor deposition (PACVD), and with a nano-layer of fluorine derivative supplementation, for reducing the risk of complications related to adhesions, and the formation of a thick postoperative scar was prepared. The biological evaluation of designed or modified medical devices is the main aspect of preclinical research. If such studies use a medical device with prolonged contact with connective tissue (more than 30 days), biocompatibility studies require a safety assessment in terms of toxicity in vitro and in vivo, allergenicity, irritation, and cancerogenicity, reproductive and developmental toxicity. The ultimate aspect of biological evaluation is biofunctionality, and evaluation of the local tissue response after implantation, resulting in the determination of all aspects of local biocompatibility with the implemented synthetic material. The implantation of PACVD-modified materials in muscle allows us to estimate the local irritation effect on the connective tissue, determining the risk of scar formation, whereas implantation of the above-mentioned knitted fabric into the abdominal wall, assists with evaluating the risk of fistula formation—the main post-surgical complications. The research aimed to evaluate the local reaction of the soft tissues after the implantation of the knitted implants modified with PACVD of the fluoropolymer in the nanostuctural form. The local effect that occurred during the implantation of the designed implants was quantitatively and qualitatively evaluated when PACVD unmodified (reference), and modified medical devices were implanted in the abdominal cavity (intra-abdominal position) for 12 or into the muscles for 56 weeks. The comparative semi-quantitative histological assessment included the severity of inflammatory cells (multinucleated cells, lymphocytes, plasma cells, macrophages, giant cells) and the tissue response (necrosis, neovascularization, fibrosis, and fat infiltration) on a five-point scale. The knitted implants modified by PACVD did not indicate cumulative tissue response when they were implanted in the muscle and intra-abdominally with direct contact with the viscera. They reduced local tissue reaction (score −2.71 after 56 weeks of the implantation) and internal organ adhesion (irritation score −2.01 and adhesion susceptibility −0.3 after 12 weeks of the implantation) compared with the reference (unmodified by PACVD) knitted implant, which had an identical structure and was made of the same source.

19 December 2024 in Materials
Verified
Journal Article
Open access
PDF file
GAGutowska Agnieszka
Gutowska Agnieszka
PKPaweł Kubiak
Paweł Kubiak
KKKatarzyna Kośla
Katarzyna Kośla
BWBożena Wilbik-Hałgas
Bożena Wilbik-Hałgas
ECEdyta Edyta Chmal-Fudali
Edyta Edyta Chmal-Fudali
MSMarcin H. Struszczyk
Marcin H. Struszczyk
This article presents an evaluation of the accelerated aging impact on the structural properties of biodegradable PLA/HAp implants produced using 3D printing technology for use in traumatic bone defect repairs in individual patients. The designed biodegradable implants were sterilized with a radiation dose of 25 ± 0.99% kGy, then exposed to an accelerated aging process. Selected physicomechanical and chemical properties of biodegradable implants were evaluated with FT-IR spectra analyses and DSC. The accelerated aging process, carried out according to the ASTM F 1980:2002 “Standard Guide for Accelerated Aging of Sterile Barrier Systems and Medical Devices”, simulates three years of implant usage. It confirmed the stability of structural, physical and mechanical properties and proved the effectiveness and safety of the implants’ application. The present study was conducted to determine the shelf-life of newly developed biodegradable implants proposed for the treatment of children and adolescents where bone growth still occurs by using accelerated aging methodologies, allowing the assessment of changes in performance that do not result in a negative impact on the safety of the medical device.

29 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
MOMagdalena Olejnik
Magdalena Olejnik
GAGutowska Agnieszka
Gutowska Agnieszka
MCMagdalena Cichecka
Magdalena Cichecka
MSMarcin H. Struszczyk
Marcin H. Struszczyk
PKPaweł Kubiak
Paweł Kubiak
Traces of potential contact from a perpetrator for evidence are one of the most frequently secured groups of evidence during the examination of the crime scene and during the examination of material in forensic laboratories. By far the most common way to secure the above-mentioned traces is the use of swabs. The literature reports indicate promising results from the use of adhesive materials for securing contact marks. The products currently on the market are not dedicated to forensic genetics or cause problems with the recovery of protected DNA at the stage of DNA isolation in the laboratory. The aim of this study was to determine the effect of conditions from an accelerated aging process carried out under simulated laboratory conditions (with aging factors as follows: UV radiation, temperature, and humidity level) on the physico-mechanical properties and chemical resistance of adhesive films made of polyethylene (PE) and polypropylene (PP). As part of the research, the influence of storage conditions on the physico-mechanical properties and chemical resistance of developed foil materials used to secure forensic traces was developed and verified. The research was carried out in conditions similar to the real ones, conducting tests of accelerated aging with the following factors: temperature, humidity, and UV radiation.

10 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
MSMarcin H. Struszczyk
Marcin H. Struszczyk
MOMagdalena Olejnik
Magdalena Olejnik
GAGutowska Agnieszka
Gutowska Agnieszka
ECEdyta Edyta Chmal-Fudali
Edyta Edyta Chmal-Fudali
OMOlga Marchut-Mikolajczyk
Olga Marchut-Mikolajczyk
PDPiotr Drożdżyński
Piotr Drożdżyński
The increasing environmental issue related to textile waste, especially synthetic fibers treated with acrylic resins, demands the creation of sustainable recycling techniques. Biotechnological methods, such as microbial degradation, present a viable solution for the elimination of these coatings and the recovery of important fibers. This study investigates the potential of a biotechnological approach for the removal of acrylic resins from coated woven textile wastes. The biodegradation process of coated woven fabric after the pretreatment at a high temperature (121 °C) or 6% H2O2 was performed using the hydrocarbon-degrading bacterial strain Gordonia alkanivorans S7. Over a 72 h biodegradation period, an increase in emulsifying and esterase activities was observed. A reduction mass of the coated textile waste by up to 7 wt% was achieved, and the elimination of acrylic resin was confirmed through FTIR analysis. The findings indicate the usefulness of the biotechnological method in eliminating acrylic resin from textile waste, presenting a viable strategy for polyester fiber recovery and substantially mitigating its environmental impact.

22 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MOMagdalena Olejnik
Magdalena Olejnik
MCMagdalena Cichecka
Magdalena Cichecka
ECEdyta Edyta Chmal-Fudali
Edyta Edyta Chmal-Fudali
MSMarcin H. Struszczyk
Marcin H. Struszczyk
PKPaweł Kubiak
Paweł Kubiak
GAGutowska Agnieszka
Gutowska Agnieszka
This study aimed to evaluate the impact of sterilization of low-adhesive films with ethylene oxide (EO) or accelerated electrons (radiation sterilization) on their performance in the context of their use to protect forensic traces. It was hypothesized that the implementation of the sterilization process made it possible to obtain functional tools for securing traces. The analysis showed that changes in surface density, density, tensile strength, and adhesion strength do not significantly affect the functional performance of the tapes. Additionally, no alterations in chemical resistance were observed following either sterilization method. The results confirm that both sterilization techniques are suitable for obtaining sterile tapes for forensic applications.