Morten Sales

Morten Sales

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MSMorten Sales
Morten Sales
Markus StroblMarkus Strobl
Markus Strobl
TSTakenao Shinohara
Takenao Shinohara
Anton TremsinAnton Tremsin
Anton Tremsin
LKLuise Theil Kuhn
Luise Theil Kuhn
SSSøren Schmidt
Søren Schmidt
Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise. Using a pioneering polarimetric set-up for ToF neutron instrumentation in combination with a newly developed tailored reconstruction algorithm, the magnetic field generated by a current carrying solenoid has been measured and reconstructed, thereby providing the proof-of-principle of a technique able to reveal hitherto unobtainable information on the magnetic fields in the bulk of materials and devices, due to a high degree of penetration into many materials, including metals, and the sensitivity of neutron polarisation to magnetic fields. The technique puts the potential of the ToF time structure of pulsed neutron sources to full use in order to optimise the recorded information quality and reduce measurement time.

25 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ACAlberto Cereser
Alberto Cereser
Markus StroblMarkus Strobl
Markus Strobl
SHStephen A. Hall
Stephen A. Hall
ASAxel Steuwer
Axel Steuwer
RKRyoji Kiyanagi
Ryoji Kiyanagi
SSSøren Schmidt
Søren Schmidt
The physical properties of polycrystalline materials depend on their microstructure, which is the nano- to centimeter scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study centimeter-sized bulk samples with a spatial resolution of hundred micrometers: time-of-flight three-dimensional neutron diffraction (ToF 3DND). Compared to existing analogous X-ray diffraction techniques, ToF 3DND enables studies of samples that can be both larger in size and made of heavier elements. Moreover, ToF 3DND facilitates the use of complicated sample environments. The basic ToF 3DND setup, utilizing an imaging detector with high spatial and temporal resolution, can easily be implemented at a time-of-flight neutron beamline. The technique was developed and tested with data collected at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Complex (J-PARC) for an iron sample. We successfully reconstructed the shape of 108 grains and developed an indexing procedure. The reconstruction algorithms have been validated by reconstructing two stacked Co-Ni-Ga single crystals, and by comparison with a grain map obtained by post-mortem electron backscatter diffraction (EBSD).

24 January 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
Markus StroblMarkus Strobl
Markus Strobl
HHHermanni Heimonen
Hermanni Heimonen
SSSoren Schmidt
Soren Schmidt
MSMorten Sales
Morten Sales
NKNikolay Kardjilov
Nikolay Kardjilov
JVJacopo Valsecchi
Jacopo Valsecchi
While neutron imaging is a well-established technique for investigations of inner structures and processes in materials, complex systems, and devices, the utilization of polarized neutron beams to visualize magnetic phenomena has been introduced only about a decade ago. In contrast to neutron scattering studies, where the interaction of the neutron’s magnetic moment with magnetic states of matter has been exploited for a long time, the direct visualization of magnetic fields in neutron imaging is a relatively new field and is still developing. Here, we give an overview of the status and provide approaches to visualizing magnetic fields with polarized neutrons, together with a report on the latest developments in attempting to record neutron tomographies for 3D reconstructions of magnetic vector fields.

12 November 2015 in Scientific Reports
Verified
Journal Article
Open access
Markus StroblMarkus Strobl
Markus Strobl
MSMorten Sales
Morten Sales
JPJeroen Plomp
Jeroen Plomp
WBWim G. Bouwman
Wim G. Bouwman
Anton TremsinAnton Tremsin
Anton Tremsin
KHKlaus Habicht
Klaus Habicht
Neutron dark-field imaging constitutes a seminal progress in the field of neutron imaging as it combines real space resolution capability with information provided by one of the most significant neutron scattering techniques, namely small angle scattering. The success of structural characterizations bridging the gap between macroscopic and microscopic features has been enabled by the introduction of grating interferometers so far. The induced interference pattern, a spatial beam modulation, allows for mapping of small-angle scattering signals and hence addressing microstructures beyond direct spatial resolution of the imaging system with high efficiency. However, to date the quantification in the small angle scattering regime is severely limited by the monochromatic approach. To overcome such drawback we here introduce an alternative and more flexible method of interferometric beam modulation utilizing a spin-echo technique. This novel method facilitates straightforward quantitative dark-field neutron imaging, i.e. the required quantitative microstructural characterization combined with real space image resolution. For the first time quantitative microstructural reciprocal space information from small angle neutron scattering becomes available together with macroscopic image information creating the potential to quantify several orders of magnitude in structure sizes simultaneously.

1 December 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RWRobin Woracek
Robin Woracek
THT. Hofmann
T. Hofmann
MBM. Bulat
M. Bulat
MSMorten Sales
Morten Sales
KHK. Habicht
K. Habicht
Markus StroblMarkus Strobl
Markus Strobl

1 May 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
Kim LefmannKim Lefmann
Kim Lefmann
KKKaspar H. Klenø
Kaspar H. Klenø
JBJonas Okkels Birk
Jonas Okkels Birk
BHBritt R. Hansen
Britt R. Hansen
SHSonja Holm-Dahlin
Sonja Holm-Dahlin
KAKen H. Andersen
Ken H. Andersen
We here describe the result of simulations of 15 generic neutron instruments for the long-pulsed European Spallation Source. All instruments have been simulated for 20 different settings of the source time structure, corresponding to pulse lengths between 1 ms and 2 ms; and repetition frequencies between 10 Hz and 25 Hz. The relative change in performance with time structure is given for each instrument, and an unweighted average is calculated. The performance of the instrument suite is proportional to (a) the peak flux and (b) the duty cycle to a power of approximately 0.3. This information is an important input to determining the best accelerator parameters. In addition, we find that in our simple guide systems, most neutrons reaching the sample originate from the central 3–5 cm of the moderator. This result can be used as an input in later optimization of the moderator design. We discuss the relevance and validity of defining a single figure-of-merit for a full facility and compare with evaluations of the individual instrument classes.