This paper presents a practical validation of a heterogeneous formation of mobile robots in performing a load lifting, transportation, and delivery task. Assuming that an unmanned ground vehicle (UGV) is unable to perform a mission by itself due to the presence of an obstacle in the navigation route, an unmanned aerial vehicle (UAV) is then assigned to lift the cargo over this UGV, transport the obstacle, and deliver over another UGV. The UAV uses an electromagnetic actuator supported by a cable to pick up the load, the mass of which is 32% of that of the UAV. Experimental results demonstrate that the developed system is capable of performing cargo transport missions and can be scalable for applications such as package delivery in urban or remote areas and supply delivery in conflict or disaster zones.
Robotic transport missions serve a variety of valuable purposes within similar contexts. These include delivering packages in urban or remote areas, dispatching supplies to disaster or conflict zones, and facilitating delivery operations. In such a context, this work deals with the cooperation and control of multiple-robot systems involving heterogeneous robot formation with sensing and actuation capabilities to perform load transportation tasks. Two off-the-shelf unmanned ground vehicles (UGVs) working cooperatively with one unmanned aerial vehicle (UAV) are used to validate the proposal. The interactions between the UAV and the UGVs are not only information exchanges but also physical couplings required to cooperate in the load’s joint transportation. The existence of an obstacle between the two UGVs makes it impossible for them to meet each other. Thus, the lifting, transport, and delivery of the load from one UGV to the other are performed by a UAV with a suspended electromagnet actuator. Experiments are performed for a weight of 165 g (load + electronic board), which corresponds to up to 36% of the UAV’s mass.
Ballet training includes exercises of high and moderate intensities, which require breathing control for a good performance. This study describes the thoracoabdominal motion of professional dancers and compares the breathing patterns between professional dancers and non-dancers. Participants of this study were four male and four female (30.33 ± 4.64 years) professional dancers and four male and four female (22.75 ± 1.49 years) non-dancers. The participants executed two breathing manoeuvres while sitting motionless: quiet breathing (QB) and vital capacity (VC). The 3D coordinates of 32 retro-reflective markers positioned on the trunk were used to calculate the volume of the superior thorax, inferior thorax and abdomen. Principal component analysis was applied in the volume variation of each trunk compartment to search for dominant independent variables in a breathing motion pattern. The correlation coefficient was calculated to verify the coordination between the compartments during the breathing manoeuvres. A predominance of the superior thorax or abdomen movement was found in both groups. The professional ballet dancers have an efficient breathing pattern and maintain the same breathing pattern in QB and VC manoeuvres. On the other hand, the non-dancers group showed relevant changes of the breathing pattern to respond to a greater breathing effort, like in VC.
1 August 2021 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Maneuvers to activate the equine's core can make a difference in their physical and psychic health. Although these activities are recommended and practiced, there is little research proving their effectiveness. This article aims to describe, through surface electromyography, the occurrences, durations and sequences activity of longissimus dorsi, rectus abdominis and gluteus medius during thoracolumbar flexion (TLF), lumbar and lumbosacral flexion (LLSF), global flexion (GF), which is the combination of TLF and LLSF, and tail traction (TT). Seven healthy adult horses of three different breeds performed five repetitions of these movements for five seconds (sec). Electromyographic activity was captured with non-invasive superficial sensors positioned in the skin regions covering these muscles. The sequence was performed once per animal, muscle activity captured by surface electromyography, data from two replicates of each animal were selected, analyzed on matLab software and data tabulation were described during each maneuver. These maneuvers provoked punctual and transient activation of muscles mentioned above, confirming the ability to activate equine core muscles. However, responses were not standardized, which means there were variations of occurrence, duration and sequence, suggesting that for practical application of those maneuvers it is necessary to perform more repetitions with longer durations to activate more muscles.
The Mangalarga Marchador (MM) breed naturally performs four-beat gaits known as “Marcha”. Kinematic analysis can provide insights for optimizing training and competition performance in this breed while potentially mitigating welfare concerns associated with extreme head and neck positions (HNPs) applied without an adequate understanding of their impacts. We examined how different HNPs affect the MM horse’s Marcha Batida gait. Four HNPs were evaluated: HPN1—loose reins, HPN2—the competition standard for MM, HPN3—an extremely elevated head and neck, and HPN4—a slightly behind-the-vertical position. Kinematic data were collected using an optoelectronic system, and diagonal dissociation, stride length, and step height were analyzed. HNP3 had the highest dissociation, shortest stride length, and higher step height compared to the other HNPs. HNP1 resulted in the longest stride length. HNP2 and HNP4 differed in diagonal dissociation. HNPs significantly impact the kinematics of the Marcha Batida gait in this cohort of Mangalarga Marchador horses. Our results confirm the benefits of HNP2, the recommended position for shows and competitions. Additionally, it discourages the use of HNP3 and reiterates the need for further research into HNPs in four-beat gaits, highlighting the importance of rider training and the careful selection of HNPs to optimize Marcha Batida performance.
This study evaluates the performance of a 32-marker motion capture (MoCap) system in estimating respiratory frequency () and tidal volume () during cycling exercise. Fourteen well-trained cyclists performed an incremental step test on a cycle ergometer, while simultaneously recording a raw flow signal with a reference metabolic cart (COSMED) and respiratory-induced torso movements with twelve optoelectronic cameras registering the position of 32 markers affixed to the torso. and were calculated from both systems on a breath-by-breath basis. The MoCap system showed a strong correlation with the COSMED system when measuring and ( = 0.99, = 0.87, respectively) during exercise. For , the mean absolute error (MAE) and mean absolute percentage error (MAPE) were 0.79 breaths/min and 2.1%, respectively. For , MoCap consistently underestimated values compared to COSMED, showing a bias (MOD ± LOA) of −0.11 ± 0.42 L and MAPE values of 8%. These findings highlight the system’s capabilities for real-time respiratory monitoring in athletic environments.