Mariangela Pinnelli

Dr. Mariangela Pinnelli

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MPMariangela Pinnelli
Mariangela Pinnelli
SMStefano Marsella
Stefano Marsella
FTFabio Tossut
Fabio Tossut
Emiliano SchenaEmiliano Schena
Emiliano Schena
RSRoberto Setola
Roberto Setola
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
In response to the escalating complexity and frequency of wildland fires, this study investigates the feasibility of using wearable devices for real-time monitoring of cardiac, respiratory, physical, and environmental parameters during live wildfire suppression tasks. Data were collected from twelve male firefighters (FFs) from the Italian National Fire Corp during a simulated protocol, including rest, running, and active fire suppression phases. Physiological and physical metrics such as heart rate (HR), heart rate variability (HRV), respiratory frequency (fR) and physical activity levels were extracted using chest straps. The protocol designed to mimic real-world firefighting scenarios revealed significant cardiovascular and respiratory strain, with HR often exceeding 85% of age-predicted maxima and sustained elevations in high-stress roles. Recovery phases highlighted variability in physiological responses, with reduced HRV indicating heightened autonomic stress. Additionally, physical activity analysis showed task-dependent intensity variations, with debris management roles exhibiting consistently high exertion levels. These findings demonstrate the relevance of wearable technology for real-time monitoring, providing an accurate analysis of key metrics to offer a comprehensive overview of work-rest cycles, informing role-specific training and operational strategies.

7 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MPMariangela Pinnelli
Mariangela Pinnelli
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
SSSergio Silvestri
Sergio Silvestri
RSRoberto Setola
Roberto Setola
Emiliano SchenaEmiliano Schena
Emiliano Schena
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
This study focuses on the integration and validation of a filtering face piece 3 (FFP3) facemask module for monitoring breathing activity in industrial environments. The key objective is to ensure accurate, real-time respiratory rate (RR) monitoring while maintaining workers’ comfort. RR monitoring is conducted through temperature variations detected using temperature sensors tested in two configurations: sensor t1, integrated inside the exhalation valve and necessitating structural mask modifications, and sensor t2, mounted externally in a 3D-printed structure, thus preserving its certification as a piece of personal protective equipment (PPE). Ten healthy volunteers participated in static and dynamic tests, simulating typical daily life and industrial occupational activities while wearing the breathing activity monitoring module and a chest strap as a reference instrument. These tests were carried out in both indoor and outdoor settings. The results demonstrate comparable mean absolute error (MAE) for t1 and t2 in both indoor (i.e., 0.31 bpm and 0.34 bpm) and outdoor conditions (i.e., 0.43 bpm and 0.83 bpm). During simulated working activities, both sensors showed consistency with MAE values in static tests and were not influenced by motion artifacts, with more than 97% of RR estimated errors within ±2 bpm. These findings demonstrate the effectiveness of integrating a smart module into protective masks, enhancing occupational health monitoring by providing continuous and precise RR data without requiring additional wearable devices.

9 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MPMariangela Pinnelli
Mariangela Pinnelli
IAIsabel Del Pilar Moscol Albanil
Isabel Del Pilar Moscol Albanil
ALAlessandro Ledda
Alessandro Ledda
Emiliano SchenaEmiliano Schena
Emiliano Schena
RSRoberto Setola
Roberto Setola
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Human activity recognition (HAR) is gaining importance in the development of smart personal protective equipment (PPE). Yet, most solutions rely on body-worn devices or invasive helmet modifications, limiting adoption in industrial settings. We propose a non-invasive smart helmet with embedded motion and environmental sensors, fully integrated into a certification-compliant shell. To explore its applicability in realistic industrial conditions, we focused on constrained acquisition scenarios—characterized by low sampling rates, limited storage, and processing capacity. A multimodal dataset was collected using embedded tri-axial accelerometers and barometric pressure sensors during operational tasks. Four classification pipelines were evaluated: Random Forest (RF), Extreme Gradient Boosting (XGBoost), a wavelet-based RF (using Horizontal Concatenation of Continuous Wavelet Transforms, HC-CWT), and a deep learning pipeline combining a Convolutional Autoencoder with LSTM (ConvAE-LSTM). Among these, XGBoost achieved the highest accuracy (up to 87.4%) and the most favorable balance between latency and computational efficiency, particularly with 8–15 s windows. This best-performing model was then deployed on the resource-constrained helmet system, confirming its suitability for on-board HAR in scalable occupational safety applications.

12 January 2026 in IEEE Sensors Letters
Verified
Journal Article
Closed access
MPMariangela Pinnelli
Mariangela Pinnelli
CRChiara Romano
Chiara Romano
SMStefano Marsella
Stefano Marsella
FTFabio Tossut
Fabio Tossut
RSRoberto Setola
Roberto Setola
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Despite its critical role in assessing physiological strain and mitigating heat- and smoke-related risks, real-time respiratory monitoring is still largely absent in wildland firefighting. This study evaluates two wearable systems for estimating respiratory rate (RR) under operational field conditions (i.e., a multistage fire suppression protocol): a face-mounted system based on a thermistor integrated into a FFP3 facemask (Mask) and a chest-worn commercial strap (Bioharness, BH) with an integrated strain sensor. RR was estimated from raw signals using frequency–domain analysis considering both 25 s and 50 s windows lengths. Pairwise comparisons were performed between RR values estimated from Mask and BH, and, respectively, between each of them and the manufacturer–generated “Summary RR” provided by the BH's onboard processor. Results underscore the influence of signal processing over sensor placement and demonstrate the feasibility of unobtrusive RR tracking using both wearable systems in dynamic, high-risk environments.

19 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Andrea NicolòAndrea Nicolò
Andrea Nicolò
ALAna Luiza de Castro Lopes
Ana Luiza de Castro Lopes
CRChiara Romano
Chiara Romano
MPMariangela Pinnelli
Mariangela Pinnelli
ASAmanda Piaia Silvatti
Amanda Piaia Silvatti
This study evaluates the performance of a 32-marker motion capture (MoCap) system in estimating respiratory frequency (fR) and tidal volume (VT) during cycling exercise. Fourteen well-trained cyclists performed an incremental step test on a cycle ergometer, while simultaneously recording a raw flow signal with a reference metabolic cart (COSMED) and respiratory-induced torso movements with twelve optoelectronic cameras registering the position of 32 markers affixed to the torso. fR and VT were calculated from both systems on a breath-by-breath basis. The MoCap system showed a strong correlation with the COSMED system when measuring fR and VT (r2 = 0.99, r2 = 0.87, respectively) during exercise. For fR, the mean absolute error (MAE) and mean absolute percentage error (MAPE) were 0.79 breaths/min and 2.1%, respectively. For VT, MoCap consistently underestimated values compared to COSMED, showing a bias (MOD ± LOA) of −0.11 ± 0.42 L and MAPE values of 8%. These findings highlight the system’s capabilities for real-time respiratory monitoring in athletic environments.

22 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LFLuca FARAMONDI
Luca FARAMONDI
Federica PascucciFederica Pascucci
Federica Pascucci
MPMariangela Pinnelli
Mariangela Pinnelli
RSRoberto Setola
Roberto Setola
This paper presents a mobile application designed to support emergency operators during indoor missions, where Global Positioning System (GPS) often fails. The system combines a wearable waist-mounted Inertial Measurement Unit (IMU) with a network of pre-installed Radio Frequency Identification (RFID) tags, enabling robust, real-time geo-referenced tracking of both personnel and critical Points of Interest (PoIs), such as resources and threats. Development was guided by interviews and surveys with emergency professionals, ensuring the tool addresses real operational needs. Key features include dynamic updates of operator positions and nearby hazards, enabled by an Indoor Positioning System (IPS) that fuses IMU and RFID data to improve accuracy in position and heading estimation. The application also offers a user-friendly Human–Environment Interface (HEI) displaying information on a spatially referenced map. By merging advanced technology with expert feedback, this system enhances safety and coordination in critical scenarios, offering a promising solution for indoor navigation and Situational Awareness (SA) in emergency response.