The fuel-cell (FC) technology currently being considered to reduce aircraft greenhouse gas emissions may require large and heavy cooling systems. The paper introduces the two-phase (2) Mechanically Pumped Loop (MPL) for FC cooling and compares it numerically with the conventional Ethylene Glycol Water (EGW) single-phase (1) cooling system for a MW heat-dissipation load. Considering an operating temperature of 90 °C, the system mass of the 2 MPL with and without an accumulator is found to be, respectively, 33% and 64% lower than the EGW system. Furthermore, the frontal area of the ram air heat exchanger (HX) was found to be 19% smaller, reducing ram air drag. An increase of the operating temperature to 130 °C was found to reduce the cooling system mass by 21% for the 1 MPL, and 22 to 29% for the 2 MPL. The frontal area of the ram air HX was found to be reduced by 44% and 40% for the 1 and 2 MPL, respectively. These results demonstrate the considerable performance gain of the 2 MPL over the 1 MPL for FC cooling, and the benefits of increasing the operating temperature for the cooling system.
The number of electronic components requiring dedicated cooling is set to increase for the next generation of medium-to-large-sized more-electric aircraft. In the EU-funded H2020 ADENEAS project, the usage of a two-phase mechanically pumped loop for the cooling of a high-power HVDC (High-Voltage Direct Current) converter, in an aircraft case, is analysed. After a fluid selection, R1233zdE appears as one of the premier candidates for aircraft two-phase pumped cooling systems. A comparison between a R1233zdE two-phase pumped cooling system and liquid cooling system with propylene–glycol water as working fluid is performed. The result of the system comparison is a 40% system mass reduction in favour of a two-phase pumped cooling system. By testing, a successful demonstration of the discussed cooling system is shown in nominal and non-nominal scenarios. With the achieved results presented here, a leap to TRL4 of a two-phase mechanically pumped loop for aircraft power electronics cooling is shown.
Hydrogen-propelled aircraft can enable net-zero CO2 emissions in aviation, which is the goal of the International Civil Aviation Organization (ICAO) for 2050. One drawback of onboard hydrogen storage in aircraft is the necessity for relatively large, pressurised storage volumes. To maximise H2 volumetric efficiency, the COmposite COnformal LIquid H2 Tank (COCOLIH2T) project attempts to design, build and test a vacuum-insulated liner-less cryogenic conformal thermoplastic composite tank with conditioning subsystems for safe operation. The tank must be compatible with the design envelope in the empennage, specifically towards the aft of the pressure bulkhead of an ATR 72-like aircraft. The tank design, analysis, optimisation and demonstrator manufacturing are presented in this paper.