Optical voltage transformers (OVTs) have been applied in power systems. When performing accuracy performance tests of OVTs large differences exist between the electromagnetic environment and the temperature variation in the laboratory and on-site. Therefore, OVTs may display different error characteristics under different conditions. In this paper, OVT prototypes with typical structures were selected to be tested for the error characteristics with the same testing equipment and testing method. The basic accuracy, the additional error caused by temperature and the adjacent phase in the laboratory, the accuracy in the field off-line, and the real-time monitoring error during on-line operation were tested. The error characteristics under the three conditions—laboratory, in the field off-line and during on-site operation—were compared and analyzed. The results showed that the effect of the transportation process, electromagnetic environment and the adjacent phase on the accuracy of OVTs could be ignored for level 0.2, but the error characteristics of OVTs are dependent on the environmental temperature and are sensitive to the temperature gradient. The temperature characteristics during on-line operation were significantly superior to those observed in the laboratory.
20 June 2022 in IEEE Transactions on Instrumentation and Measurement
DC electronic instrument transformers (DCEIT) are widely used in the voltage source converter based high voltage direct current transmission (VSC-HVDC) system to measure the bus voltage or current, and should be of accurate and quick transient response. The transient performance of the DCEIT need to be calibrated using a calibrator. The existing schemes are difficult to recognize different transient step responses automatically, and usually require human intervention, which limits their flexibility and applicability. Besides, the accuracy of the calculated results is affected by human factors. A self-adaptive algorithm of transient performance analysis is proposed. It recognizes the characteristics of the transient step response based on wavelet analysis, and distinguishes the steady-state and step intervals automatically. Then it evaluates and finds the stable data segments in the steady-state intervals adaptively to calculate the high and low steady-state values. Finally, the data in the step interval are interpolated to search the feature points of the waveform, and then the transient response parameters are calculated according to the coordinates of feature points. In the validation stage, six kinds of step response waveforms are generated by MATLAB to test the performance of the proposed algorithm. Compared with the boundary window method, the proposed algorithm could recognize the characteristics of the tested waveforms automatically and achieve a more accurate analyses of transient performance. In addition, a calibrator prototype based on the proposed algorithm is developed, and some tests are carried out at the National Center for High Voltage Measurement (NCHVM) in China, whose results verify the feasibility of the algorithm.
In this paper, a series of electromagnetically-induced-transparent (EIT) spectra of different Rydberg states, controlled by microwaves, in rubidium (Rb) thermal vapor are presented. The novel evolution regularity for different Rydberg states can be found by experimentally detected transmitted EIT spectra, which can reveal the primary quantum number of different Rydberg states and how to influence microwave control spectroscopy evolution regularity, and which can pave the way in order to address the challenge of selecting Rydberg states for applications in Rydberg microwave field detection. This is helpful for the development of measuring standards of the microwave field in Rydberg states.
We investigate the optical response properties of an atom-assisted spinning optomechanical system, in which a spinning optical resonator is coupled simultaneously to a two-level atomic ensemble and a mechanical resonator driven by a weak pump field. Remarkably, we demonstrate that by simply reversing the rotation direction, the system can be switched between a low-absorption electromagnetic and optomechanically induced transparency state and a high-absorption state, constituting a form of non-reciprocal optical control at the quantum level. Furthermore, by tuning the phase difference between the mechanical pump and the probe field, direction-dependent switching between absorption and gain is achieved. These non-reciprocal effects originate from the Sagnac-induced frequency shift in the optical mode, which leads to distinct optomechanical and atom–cavity couplings for opposite spinning directions. We also show that the absorption spectrum can be modulated by the angular velocity and the atomic number. Our results indicate that the optical properties of the hybrid system can be manipulated via the angular velocity, phase difference, and atom number, with potential applications in chiral photonic communications.
10 April 2026 in IEEE Transactions on Instrumentation and Measurement
The nitrogen-vacancy centers in diamond have exhibited excellent sensing capabilities. By applying the resonance frequency tracking (RFT) method in a closed-loop system, magnetic-field measurements with a wide dynamic range have been demonstrated. However, the previous strategies employ phase-sensitive control signals, which degrade control robustness and reduce tracking rates, thereby impeding real-time measurements. Here, an amplitude–phase joint discrimination strategy is proposed to improve robustness, overcoming the limitations of existing strategies that are sensitive to phase delays in fluorescence signal transmission. Moreover, to improve the tracking speed, a customized device, integrating a fast-response lock-in amplifier (LIA) and a frequency-agile microwave (MW) source, is reported. The LIA achieves a response time as short as 20 μs, while the MW source reaches a frequency switching time of 1 μs. The proposed strategy and customized device are implemented and evaluated on an all-fiber quantum current sensing system. Test results show that the system achieves a maximum sampling rate of 20 kHz, with excellent linearity (a linear deviation of 0.37% over the range of 0-120 A) and high accuracy (a measurement error of 0.73% at 80 A), making it promising for a wide range of high-speed quantum measurement scenarios.