Jacek Wojtas

Jacek Wojtas

Institute of Optoelectronics, Military University of Technology, 2 Urbanowicza Str., 00-908 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZBZbigniew Bielecki
Zbigniew Bielecki
TSTadeusz Stacewicz
Tadeusz Stacewicz
Janusz SmulkoJanusz Smulko
Janusz Smulko
Jacek WojtasJacek Wojtas
Jacek Wojtas
High precision and fast measurement of gas concentrations is important for both understanding and monitoring various phenomena, from industrial and environmental to medical and scientific applications. This article deals with the recent progress in ammonia detection using in-situ solid-state and optical methods. Due to the continuous progress in material engineering and optoelectronic technologies, these methods are among the most perceptive because of their advantages in a specific application. We present the basics of each technique, their performance limits, and the possibility of further development. The practical implementations of representative examples are described in detail. Finally, we present a performance comparison of selected practical application, accumulating data reported over the preceding decade, and conclude from this comparison.

23 September 2013 in Bioanalysis
Verified
Journal Article
Closed access
BBBogusław Buszewski
Bogusław Buszewski
DGDamian Grzywinski
Damian Grzywinski
TLTomasz Ligor
Tomasz Ligor
TSTadeusz Stacewicz
Tadeusz Stacewicz
ZBZygmunt Bielecki
Zygmunt Bielecki
Jacek WojtasJacek Wojtas
Jacek Wojtas
Breath is a rich mixture containing numerous volatile organic compounds at trace amounts (ppbv-pptv level) such as: hydrocarbons, alcohols, ketones, aldehydes, esters or heterocycles. The presence of some of them depends on health status. Therefore, breath analysis might be useful for clinical diagnostics, therapy monitoring and control of metabolic or biochemical cell cycle products. This Review presents an update on the latest developments in breath analysis applied to diagnosing different diseases with the help of high-quality equipment. Efforts were made to fully and accurately describe traditional and modern techniques used to determine the components of breath. The techniques were compared in terms of design, function and also detection limit of different volatile organic compounds. GC with different detectors, MS, optical sensor and laser spectroscopic detection techniques are also discussed.

2 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ARAntoni Rogalski
Antoni Rogalski
ZBZbigniew Bielecki
Zbigniew Bielecki
JMJanusz Mikolajczyk
Janusz Mikolajczyk
Jacek WojtasJacek Wojtas
Jacek Wojtas
The paper presents the long-term evolution and recent development of ultraviolet photodetectors. First, the general theory of ultraviolet (UV) photodetectors is briefly described. Then the different types of detectors are presented, starting with the older photoemission detectors through photomultipliers and image intensifiers. More attention is paid to silicon and different types of wide band gap semiconductor photodetectors such as AlGaN, SiC-based, and diamond detectors. Additionally, Ga2O3 is considered a promising material for solar-blind photodetectors due to its excellent electrical properties and a large bandgap energy. The last part of the paper deals with new UV photodetector concepts inspired by new device architectures based on low-dimensional solid materials. It is shown that the evolution of the architecture has shifted device performance toward higher sensitivity, higher frequency response, lower noise, and higher gain-bandwidth products.

1 April 2020 in Journal of Hazardous Materials
Verified
Journal Article
Open access
ADAnna Dettlaff
Anna Dettlaff
PJP. Jakóbczyk
P. Jakóbczyk
MFM. Ficek
M. Ficek
BWB. Wilk
B. Wilk
MSM. Szala
M. Szala
RBRobert Bogdanowicz
Robert Bogdanowicz
The study is devoted to the electrochemical detection of trace explosives on boron-doped diamond/graphene nanowall electrodes (B:DGNW). The electrodes were fabricated in a one-step growth process using chemical vapour deposition without any additional modifications. The electrochemical investigations were focused on the determination of the important nitroaromatic explosive compounds, 2,4,6-trinitrotoluene (TNT) and 2,4,6-trinitroanisole (TNA). The distinct reduction peaks of both studied compounds were observed regardless of the pH value of the solution. The reduction peak currents were linearly related to the concentration of TNT and TNA in the range from 0.05-15 ppm. Nevertheless, two various linear trends were observed, attributed respectively to the adsorption processes at low concentrations up to the diffusional character of detection for larger contamination levels. The limit of detection of TNT and TNA is equal to 73 ppb and 270 ppb, respectively. Moreover, the proposed detection strategy has been applied under real conditions with a significant concentration of interfering compounds - in landfill leachates. The proposed bare B:DGNW electrodes were revealed to have a high electroactive area towards the voltammetric determination of various nitroaromatic compounds with a high rate of repeatability, thus appearing to be an attractive nanocarbon surface for further applications.

1 January 2012 in Opto-Electronics Review
Verified
Journal Article
Closed access
Jacek WojtasJacek Wojtas
Jacek Wojtas
ZBZbigniew Bielecki
Zbigniew Bielecki
TST. Stacewicz
T. Stacewicz
JMJanusz Mikolajczyk
Janusz Mikolajczyk
MNM. Nowakowski
M. Nowakowski
At present there are many reasons for seeking new methods and technologies that aim to develop new and more perfect sensors for different chemical compounds. However, the main reasons are safety ensuring and health care. In the paper, recent advances in the human breath analysis by the use of different techniques are presented. We have selected non-invasive ones ensuring detection of pathogenic changes at a molecular level. The presence of certain molecules in the human breath is used as an indicator of a specific disease. Thus, the analysis of the human breath is very useful for health monitoring. We have shown some examples of diseases’ biomarkers and various methods capable of detecting them. Described methods have been divided into non-optical and optical methods. The former ones are the following: gas chromatography, flame ionization detection, mass spectrometry, ion mobility spectrometry, proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry. In recent twenty years, the optical methods have become more popular, especially the laser techniques. They have a great potential for detection and monitoring of the components in the gas phase. These methods are characterized by high sensitivity and good selectivity. The spectroscopic sensors provide the opportunity to detect specific gases and to measure their concentration either in a sampling place or a remote one. Multipass spectroscopy, cavity ring-down spectroscopy, and photo-acoustic spectroscopy were characterised in the paper as well.

1 January 2012 in Metrology and Measurement Systems
Verified
Journal Article
Open access
PDF file
ZBZbigniew Bielecki
Zbigniew Bielecki
JJJacek Janucki
Jacek Janucki
AKAdam Kawalec
Adam Kawalec
JMJanusz Mikolajczyk
Janusz Mikolajczyk
NPNorbert Pałka
Norbert Pałka
Jacek WojtasJacek Wojtas
Jacek Wojtas
Sensors and Systems for the Detection of Explosive Devices - An Overview: The paper presents analyses of current research projects connected with explosive material sensors. Sensors are described assigned to X and γ radiation, optical radiation sensors, as well as detectors applied in gas chromatography, electrochemical and chemical sensors. Furthermore, neutron techniques and magnetic resonance devices were analyzed. Special attention was drawn to optoelectronic sensors of explosive devices.