Thomas Seppi

Prof. Dr. Thomas Seppi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JMJulian Mangesius
Julian Mangesius
TSThomas Seppi
Thomas Seppi
RWRocco Weigel
Rocco Weigel
CAChristoph Reinhold Arnold
Christoph Reinhold Arnold
DVDanijela Vasiljevic
Danijela Vasiljevic
MNMeinhard Nevinny-Stickel
Meinhard Nevinny-Stickel
Background: The present study investigates the intrafractional accuracy of a frameless thermoplastic mask used for head immobilization during stereotactic radiotherapy. Non-invasive masks cannot completely prohibit head movements. Previous studies attempted to estimate the magnitude of intrafractional inaccuracy by means of pre- and postfractional measurements only. However, this might not be sufficient to accurately map also intrafractional head movements. Materials and methods: Intrafractional deviation of mask-fixed head positions was measured in five patients during a total of 94 fractions by means of close-meshed repeated ExacTrac measurements (every 1.4 min) conducted during the entire treatment session. A median of six (range: 4 to 11) measurements were recorded per fraction, delivering a dataset of 453 measurements. Results: Random errors (SD) for the x, y and z axes were 0.27 mm, 0.29 mm and 0.29 mm, respectively. Median 3D deviation was 0.29 mm. Of all 3D intrafractional motions, 5.5 and 0.4% exceeded 1 mm and 2 mm, respectively. A moderate correlation between treatment duration and mean 3D displacement was determined (rs = 0.45). Mean 3D deviation increased from 0.21 mm (SD = 0.26 mm) in the first 2 min to a maximum of 0.53 mm (SD = 0.31 mm) after 10 min of treatment time. Conclusion: Pre- and post-treatment measurement is not sufficient to adequately determine the range of intrafractional head motion. Thermoplastic masks provide both reliable interfractional and intrafractional immobilization for image-guided stereotactic hypofractionated radiotherapy. Greater positioning accuracy may be obtained by reducing treatment duration (< 6 min) and applying intrafractional correction. Trial registration: Clinicaltrials.gov, NCT03896555, Registered 01 April 2019 - retrospectively registered.

14 December 2022 in Strahlentherapie und Onkologie
Verified
Journal Article
Open access
PDF file
JMJulian Mangesius
Julian Mangesius
DMDanijela Minasch
Danijela Minasch
KFKatharina Fink
Katharina Fink
MNMeinhard Nevinny-Stickel
Meinhard Nevinny-Stickel
PLPeter Lukas
Peter Lukas
TSThomas Seppi
Thomas Seppi
Purpose: A major complication of sequential and concomitant chemoradiation in breast cancer treatment is interstitial pneumonitis induced by radiation therapy (RT), systemic therapy, or a combination of both. Dose and volume of co-irradiated lung tissue directly correlate with the risk of radiation pneumonitis. Especially in case of combined treatment, it is often unclear which of the used therapeutic agents promote pneumonitis. Methods: This was a prospective monocentric study including 396 breast cancer patients. A systematic analysis of single and combined therapeutic measures was performed in order to identify treatment-related factors enhancing the risk of pneumonitis post RT. Results: Overall incidence of pneumonitis of any grade was 38%; 28% were asymptomatic (grade 1) and 10% were symptomatic (> grade 1). Pneumonitis > grade 2 did not occur. Beside age, smoking status, and mean lung dose, the combined treatment with goserelin and tamoxifen significantly enhanced the risk of pneumonitis in a supra-additive pattern (odds ratio [OR] 4.38), whereas each agent alone or combined with other drugs only nonsignificantly contributed to a higher pneumonitis incidence post RT (OR 1.52 and OR 1.16, respectively). None of the other systemic treatments, including taxanes, increased radiation pneumonitis risk in sequential chemoradiation. Conclusion: Common treatment schedules in sequential chemoradiation following breast-conserving surgery only moderately increase lung toxicity, mainly as an asymptomatic complication, or to a minor extent, as transient pneumonitis ≤ grade 2. However, combined treatment with tamoxifen and the LHRH analog goserelin significantly increased the risk of pneumonitis in breast cancer patients after chemoradiation. Thus, closer surveillance of involved patients is advisable.

24 April 2020 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
TSThomas Schmiedinger
Thomas Schmiedinger
SPStefan Partel
Stefan Partel
TLThomas Lechleitner
Thomas Lechleitner
OEOliver Eiter
Oliver Eiter
DHDaniel Hekl
Daniel Hekl
TSThomas Seppi
Thomas Seppi
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 μm electrode width and 50 μm inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubularLLC-PK1cells, representing a normal functional transporting epithelium, and human cervical cancer-derivedHeLacells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring as sensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance in comparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.

1 November 2023 in Cancers
Verified
Journal Article
Open access
PDF file
SVSamuel Vorbach
Samuel Vorbach
JMJulian Mangesius
Julian Mangesius
DDDaniel Dejaco
Daniel Dejaco
TSThomas Seppi
Thomas Seppi
MSMatthias Santer
Matthias Santer
MNMeinhard Nevinny-Stickel
Meinhard Nevinny-Stickel
Current literature regarding survival and treatment outcome of SBRT in patients with pulmonary oligometastatic head and neck squamous cell carcinoma (HNSCC) is limited. Additionally, most of the published studies include metastatic lesions deriving also from primaries with histologies other than SCC when investigating the outcome of SBRT. The aim of the present retrospective study is to explore local control (LC) of treated metastases, progression-free survival (PFS), and overall survival (OS) of exclusively pulmonary oligometastatic HNSCC-patients treated with SBRT. Between 2006 and 2021, a total of 46 patients were treated with SBRT for a maximum of four pulmonary oligometastases (PM) concurrently (mean PM per patient = 2.0; range 1 to 6 PM, total of 92). Of these, 17 patients (37.0%) developed new pulmonary metastases after their first SBRT. Repeated courses of SBRT were required once in 15 patients (88.2%) and twice in 2 patients (11.8%). Median follow-up was 17 months (range, 0–109 months). One year after completion of SBRT, LC rate, PFS, and OS were 98.7%, 37.9%, and 79.5%, respectively. After two years, LC rate, PFS, and OS were 98.7%, 28.7%, and 54.9%; as well as 98.7%, 16.7%, and 31.0% after five years. Radiochemotherapy (HR 2.72, p < 0.001) or radiotherapy as primary treatment (HR 8.60; p = 0.003), as well as reduced patient performance status (HR 48.30, p = 0.002), were associated with lower PFS. Inferior OS correlated with poor performance status (HR 198.51, p < 0.001) and surgery followed by radiochemotherapy (HR 4.18, p = 0.032) as primary treatment, as well as radiotherapy alone (HR 7.11, p = 0.020). Treatment of more than one PM is an independent predictor of impaired OS (HR 3.30, p = 0.016). SBRT of HNSCC-derived PMs results in excellent LC rates and encouraging OS rates of 54.9% at two years along with good tolerability (no more than grade 2 toxicities). Favourable outcome and low toxicity also apply to repeated courses of SBRT of newly emerging PMs.

26 March 2024 in Current Oncology
Verified
Journal Article
Open access
PDF file
JMJulian Mangesius
Julian Mangesius
TSThomas Seppi
Thomas Seppi
CAChristoph Reinhold Arnold
Christoph Reinhold Arnold
SMStephanie Mangesius
Stephanie Mangesius
JKJohannes Kerschbaumer
Johannes Kerschbaumer
UGUte Ganswindt
Ute Ganswindt
This study aims to evaluate the clinical outcome of stereotactic radiosurgery as the sole treatment for brain metastases and to assess prognostic factors influencing survival. A total of 108 consecutive patients with 213 metastases were retrospectively analyzed. Treatment was determined with close-meshed MRI follow-up. Various prognostic factors were assessed, and several prognostic indices were compared regarding their reliability to estimate overall survival. Median overall survival was 15 months; one-year overall survival was 50.5%. Both one- and two-year local controls were 90.9%. The rate of new metastases after SRS was 49.1%. Multivariate analysis of prognostic factors revealed that the presence of extracranial metastases, male sex, lower KPI, and progressive extracranial disease were significant risk factors for decreased survival. Of all evaluated prognostic indices, the Basic Score for Brain Metastases (BSBMs) showed the best correlation with overall survival. A substantial survival advantage was found for female patients after SRS when compared to male patients (18 versus 9 months, p = 0.003). SRS of brain metastasis is a safe and effective treatment option when frequent monitoring for new metastases with MRI is performed. Common prognostic scores lack reliable estimation of survival times. Female sex should be considered as an additional independent positive prognostic factor influencing survival.

31 July 2023 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Open access
PDF file
JMJulian Mangesius
Julian Mangesius
TSThomas Seppi
Thomas Seppi
RIRamine Ibrahim
Ramine Ibrahim
KFKatrin Fleischmann
Katrin Fleischmann
AGAngela Ginestet
Angela Ginestet
UGUte Ganswindt
Ute Ganswindt
Introduction: Recent advances in the radiation therapy of prostate cancer have brought a shift toward moderate- and ultra-hypofractionated treatment schedules. Reducing safety margins can broaden the therapeutic window in stereotactic treatments and alleviate concerns for toxicity in high dose-per-fraction treatment schedules. Management of intrafractional motion is a necessity for stereotactic body radiation therapy (SBRT). It can be achieved by performing intrafractional image guidance and position corrections. We evaluate the suitability of such a novel prostate motion management system and its potential benefit for treatment accuracy. Methods: Intrafractional IGRT was performed for 22 patients during 149 treatment sessions using repeated orthogonal kV-XR imaging of implanted fiducial markers with the ExacTrac Dynamic (EXTD) system. Position measurements were taken four times during each arc of the applied volumetric modulated arc therapy (VMAT). Position correction was performed if translational deviation exceeded 2 mm in any direction. Results: Of 677 single EXTD measurements, 20.6% exceeded the predefined threshold of 2 mm 3D deviation. Without intrafractional corrections, 39.4% of all individual measurements would exceed the threshold. The 3D accuracy could thus significantly be improved, reducing mean 3D shifts from 1.97 (± 1.44) mm to 1.39 (± 1.01) mm by performing intrafractional IGRT. In total, 34% of all treatment sessions required correction of intrafractional position shifts. Conclusion: Monitoring of prostate motion using repeated intrafractional orthogonal kV-X-ray-based position measurements of implanted fiducial markers proved to be a reliable method to improve precision of stereotactic irradiations of the prostate. It can prevent unacceptable translation deviations in one third of all sessions.