Stefan Partel

Stefan Partel

Auto-generated profile, based on publicly available information

Stefan Partel

Vorarlberg University of Applied Sciences, Research Center of Microtechnology, Dornbirn, Austria

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
MNMichael Niedermayr
Michael Niedermayr
KLKirill Lakhmanskiy
Kirill Lakhmanskiy
MKMuir Kumph
Muir Kumph
SPStefan Partel
Stefan Partel
JEJonannes Edlinger
Jonannes Edlinger
RBRainer Blatt
Rainer Blatt
Trapped ions are pre-eminent candidates for building quantum information processors and quantum simulators. To scale such systems to more than a few tens of ions it is important to tackle the observed high ion-heating rates and create scalable trap structures which can be simply and reliably produced. Here, we report on cryogenically operated intrinsic-silicon ion traps which can be rapidly and easily fabricated using standard semiconductor technologies. Single 40Ca+ ions have been trapped and used to characterize the trap operation. Long ion lifetimes were observed with the traps exhibiting heating rates as low as 0.33 phonons s−1 at an ion-electrode distance of 230 μm. These results open many new avenues to arrays of micro-fabricated ion traps.

14 November 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SPSeungHyun Park
SeungHyun Park
YKYong Jae Kim
Yong Jae Kim
EKElisabeth Kostal
Elisabeth Kostal
VMVolha Matylitskaya
Volha Matylitskaya
SPStefan Partel
Stefan Partel
WRWonHyoung Ryu
WonHyoung Ryu
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.

4 January 2020 in Polymers
Verified
Journal Article
Open access
PDF file
FWFelicia Wieland
Felicia Wieland
RBRichard Bruch
Richard Bruch
MBMichael Bergmann
Michael Bergmann
SPStefan Partel
Stefan Partel
GUGerald A. Urban
Gerald A. Urban
Can DincerCan Dincer
Can Dincer
Over the last years, polymers have gained great attention as substrate material, because of the possibility to produce low-cost sensors in a high-throughput manner or for rapid prototyping and the wide variety of polymeric materials available with different features (like transparency, flexibility, stretchability, etc.). For almost all biosensing applications, the interaction between biomolecules (for example, antibodies, proteins or enzymes) and the employed substrate surface is highly important. In order to realize an effective biomolecule immobilization on polymers, different surface activation techniques, including chemical and physical methods, exist. Among them, plasma treatment offers an easy, fast and effective activation of the surfaces by micro/nanotexturing and generating functional groups (including carboxylic acids, amines, esters, aldehydes or hydroxyl groups). Hence, here we present a systematic and comprehensive plasma activation study of various polymeric surfaces by optimizing different parameters, including power, time, substrate temperature and gas composition. Thereby, the highest immobilization efficiency along with a homogenous biomolecule distribution is achieved with a 5-min plasma treatment under a gas composition of 50% oxygen and nitrogen, at a power of 1000 W and a substrate temperature of 80 °C. These results are also confirmed by different surface characterization methods, including SEM, XPS and contact angle measurements.

27 March 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
ATAna I. F. Tresguerres-Mata
Ana I. F. Tresguerres-Mata
CLChristian Lanza
Christian Lanza
JTJavier Taboada-Gutiérrez
Javier Taboada-Gutiérrez
JMJoseph. R. Matson
Joseph. R. Matson
Gonzalo Álvarez-PérezGonzalo Álvarez-Pérez
Gonzalo Álvarez-Pérez
PGPablo Alonso González
Pablo Alonso González
Polariton canalization is characterized by intrinsic collimation of energy flow along a single crystalline axis. This optical phenomenon has been experimentally demonstrated at the nanoscale by stacking and twisting van der Waals (vdW) layers of α-MoO3, by combining α-MoO3 and graphene, or by fabricating an h-BN metasurface. However, these material platforms have significant drawbacks, such as complex fabrication and high optical losses in the case of metasurfaces. Ideally, it would be possible to canalize polaritons “naturally” in a single pristine layer. Here, we theoretically predict and experimentally demonstrate naturally canalized phonon polaritons (PhPs) in a single thin layer of the vdW crystal LiV2O5. In addition to canalization, PhPs in LiV2O5 exhibit strong field confinement ( $${{{{{{\boldsymbol{\lambda }}}}}}}_{{{{{{\bf{p}}}}}}} \sim \frac{{{{{{{\boldsymbol{\lambda }}}}}}}_{{{{{{\bf{0}}}}}}}}{{{{{{\bf{27}}}}}}}$$ λ p ~ λ 0 27 ), slow group velocity (0.0015c), and ultra-low losses (lifetimes of 2 ps). Our findings are promising for the implementation of low-loss optical nanodevices where strongly directional light propagation is needed, such as waveguides or optical routers.

14 February 2025 in Science Advances
Verified
Journal Article
Open access
JDJiahua Duan
Jiahua Duan
AMAitana Tarazaga Martín-Luengo
Aitana Tarazaga Martín-Luengo
CLChristian Lanza
Christian Lanza
SPStefan Partel
Stefan Partel
KVKirill Voronin
Kirill Voronin
PGPablo Alonso González
Pablo Alonso González
Canalization is an optical phenomenon that enables unidirectional light propagation without predefined waveguiding designs. Recently demonstrated using phonon polaritons in twisted van der Waals (vdW) layers of α-MoO 3 , it offers unprecedented possibilities for controlling light-matter interactions at the nanoscale. However, practical applications have been hindered by the complex sample fabrication of twisted stacks. In this work, we introduce a previously unexplored canalization phenomenon in a single-thin vdW layer (α-MoO 3 ) interfaced with a substrate exhibiting a given negative permittivity. This enables a proof-of-concept application of polariton canalization: super-resolution nanoimaging (~λ 0 /220). Canalization-based imaging transcends conventional projection constraints, allowing the super-resolution images to be obtained at any desired location in the image plane. This versatility stems from the synergetic manipulation of three key parameters: incident frequency, rotation angle of the thin vdW layer, and thickness. Our results provide insights into the properties of canalization and constitute a seminal step toward multifaceted photonic applications, including imaging, data transmission, and ultracompact photonic integration.

1 April 2017 in Microelectronic Engineering
Verified
Journal Article
Closed access
SPS. Partel
S. Partel
SKS. Kasemann
S. Kasemann
VMV. Matylitskaya
V. Matylitskaya
CTC. Thanner
C. Thanner
Can DincerCan Dincer
Can Dincer
GUG. Urban
G. Urban