José Roberto Espinosa Lumbreras

Dr. José Roberto Espinosa Lumbreras


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2021 in Molecules
Verified
Journal Article
Open access
PDF file
JLJosé Roberto Espinosa Lumbreras
José Roberto Espinosa Lumbreras
MVMarisol Galvan Valencia
Marisol Galvan Valencia
AQArturo S. Quiñones
Arturo S. Quiñones
JAJorge Luis Ayala-Luján
Jorge Luis Ayala-Luján
VVVerónica Ávila Vázquez
Verónica Ávila Vázquez
SDSERGIO MIGUEL DURON-TORRES
SERGIO MIGUEL DURON-TORRES
In this work, a low-cost and rapid electrochemical resistive DNA biosensor based on the current relaxation method is described. A DNA probe, complementary to the specific human papillomavirus type 16 (HPV-16) sequence, was immobilized onto a screen-printed gold electrode. DNA hybridization was detected by applying a potential step of 30 mV to the system, composed of an external capacitor and the modified electrode DNA/gold, for 750 µs and then relaxed back to the OCP, at which point the voltage and current discharging curves are registered for 25 ms. From the discharging curves, the potential and current relaxation were evaluated, and by using Ohm’s law, the charge transfer resistance through the DNA-modified electrode was calculated. The presence of a complementary sequence was detected by the change in resistance when the ssDNA is transformed in dsDNA due to the hybridization event. The target DNA concentration was detected in the range of 5 to 20 nM. The results showed a good fit to the regression equation ΔRtotal(Ω)=2.99 × [DNA]+81.55, and a detection limit of 2.39 nM was obtained. As the sensing approach uses a direct current, the electronic architecture of the biosensor is simple and allows for the separation of faradic and nonfaradaic contributions. The simple electrochemical resistive biosensor reported here is a good candidate for the point-of-care diagnosis of HPV at a low cost and in a short detection time.

13 July 2025 in Metals
Verified
Journal Article
Open access
PDF file
AMAlfredo E. Molina-Castillo
Alfredo E. Molina-Castillo
Enrique Alejandro Lopez BaltazarEnrique Alejandro Lopez Baltazar
Enrique Alejandro Lopez Baltazar
FAFrancisco Alvarado-Hernández
Francisco Alvarado-Hernández
Salvador Gomez-JimenezSalvador Gomez-Jimenez
Salvador Gomez-Jimenez
JLJosé Roberto Espinosa Lumbreras
José Roberto Espinosa Lumbreras
Víctor H. Baltazar-HernándezVíctor H. Baltazar-Hernández
Víctor H. Baltazar-Hernández
An ultra-high-strength press-hardening steel (PHS) and a high-strength dual-phase steel (DP) were butt-joined by the gas metal arc welding (GMAW) process, aiming to assess the effects of a high heat input welding process on the structure-property relationship and residual stress. The post-weld microstructure, the microhardness profile, the tensile behavior, and the experimentally obtained residual stresses (by x-ray diffraction) of the steels in dissimilar (PHS-DP) and similar (PHS-PHS, DP-DP) pair combinations have been analyzed. Results indicated that the ultimate tensile strength (UTS) of the dissimilar pair PHS-DP achieves a similar strength to the DP-DP joint, whereas the elongation was similar to that of the PHS-PHS weldment. The failure location of the tensile specimens was expected and systematically observed at the tempered and softer sub-critical heat-affected zone (SC-HAZ) in all welded conditions. Compressive residual stresses were consistently observed along the weldments in all specimens; the more accentuated negative RS were measured in the PHS joint attributed to the higher volume fraction of martensite; furthermore, the negative RS measured in the fusion zone (FZ) could be well correlated to weld restraint due to the sheet anchoring during the welding procedure, despite the presence of predominant ferrite and pearlite microstructures.