Alexandru Dorobanțiu

Mr. Alexandru Dorobanțiu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2025 in Communications Medicine
Verified
Journal Article
Open access
PDF file
OPOriana Presacan
Oriana Presacan
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
JIJonas Isaksen
Jonas Isaksen
TWTobias Willi
Tobias Willi
CGClaus Graff
Claus Graff
Vajira Lasantha ThambawitaVajira Lasantha Thambawita
Vajira Lasantha Thambawita
Background: Wearables with integrated electrocardiogram (ECG) acquisition have made single-lead ECGs widely accessible to patients and consumers. However, the 12-lead ECG remains the gold standard for most clinical cardiac assessments. In this study, we developed a neural network to reconstruct 12-lead ECGs from single-lead and dual-lead ECGs, and evaluated the mathematical accuracy. Methods: We used lead I or leads I and II from 9514 individuals from the Physikalisch-Technische Bundesanstalt (PTB-XL) cohort and a generative adversarial network, with the aim of recreating the missing leads from the 12-lead ECG. ECGs were divided into training, validation, and testing (10%). Original and recreated leads were measured with a commercially available algorithm. Differences in means and variances were assessed with Student’s t-tests and F-tests, respectively. Calibration and bias were assessed with Bland-Altman plots. Inter-lead correlations were compared in original and recreated ECGs. Results: The variability of precordial ECG amplitudes is significantly reduced in recreated ECGs compared to real ECGs (all p < 0.05), indicating regression-to-the-mean. Amplitude averages are recreated with bias (p < 0.05 for most leads). Reconstruction errors depend on the real amplitudes, suggesting regression-to-the-mean (R 2 between target and error in R-peak amplitude in lead V3: 0.92). The relations between lead markers have a similar slope but are much stronger due to reduced variance (R-peak amplitude R 2 between leads I and V3, real ECGs: 0.04, recreated ECGs: 0.49). Using two leads does not significantly improve 12-lead recreation. Conclusions: AI-based 12-lead ECG reconstruction results in a regression-to-the-mean effect rather than personalized output, rendering it unsuitable for clinical use.

19 April 2021 in Future Internet
Verified
Journal Article
Open access
PDF file
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
VOValentin Ogrean
Valentin Ogrean
Remus BradRemus Brad
Remus Brad
The mesh-type coronary model, obtained from three-dimensional reconstruction using the sequence of images produced by computed tomography (CT), can be used to obtain useful diagnostic information, such as extracting the projection of the lumen (planar development along an artery). In this paper, we have focused on automated coronary centerline extraction from cardiac computed tomography angiography (CCTA) proposing a 3D version of U-Net architecture, trained with a novel loss function and with augmented patches. We have obtained promising results for accuracy (between 90–95%) and overlap (between 90–94%) with various network training configurations on the data from the Rotterdam Coronary Artery Centerline Extraction benchmark. We have also demonstrated the ability of the proposed network to learn despite the huge class imbalance and sparse annotation present in the training data.

6 April 2021
Verified
Book Chapter
Closed access
PDF file
Stefan-Alexandru PrecupStefan-Alexandru Precup
Stefan-Alexandru Precup
Arpad GellertArpad Gellert
Arpad Gellert
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
CZConstantin-Bala Zamfirescu
Constantin-Bala Zamfirescu

2 September 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAkriti Sharma
Akriti Sharma
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
SASaquib Ali
Saquib Ali
MIMario Iliceto
Mario Iliceto
MSMette H. Stensen
Mette H. Stensen
HHHugo L. Hammer
Hugo L. Hammer
Background: In assisted reproductive technology, evaluating the quality of the embryo is crucial when selecting the most viable embryo for transferring to a woman. Assessment also plays an important role in determining the optimal transfer time, either in the cleavage stage or in the blastocyst stage. Several AI-based tools exist to automate the assessment process. However, none of the existing tools predicts upcoming video frames to assist embryologists in the early assessment of embryos. In this paper, we propose an AI system to forecast the dynamics of embryo morphology over a time period in the future. Methods: The AI system is designed to analyze embryo development in the past two hours and predict the morphological changes of the embryo for the next two hours. It utilizes a novel predictive model incorporating Convolutional LSTM layers for recursive forecasting, enabling prediction of future embryo morphology by analyzing prior changes in the video sequence and predicting embryo development up to 23 hours ahead. Results: The results demonstrated that the AI system could accurately forecast embryo development at the cleavage stage on day 2 and the blastocyst stage on day 4. The system provided valuable information on the cell division processes on day 2 and the start of the blastocyst stage on day 4. The system focused on specific developmental features effective across both the categories of embryos. The embryos that were transferred to the female, and the embryos that were discarded. However, in the ‘transfer’ category, the forecast had a clearer cell membrane and less distortion as compared to the ‘avoid’ category. Conclusion: This study assists in the embryo evaluation process by providing early insights into the quality of the embryo for both the transfer and avoid categories of videos. The embryologists recognize the ability of the forecast to depict the morphological changes of the embryo. Additionally, enhancement in image quality has the potential to make this approach relevant in clinical settings.

6 March 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
ASAkriti Sharma
Akriti Sharma
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
SASaquib Ali
Saquib Ali
MIMario Iliceto
Mario Iliceto
MSMette H. Stensen
Mette H. Stensen
HHHugo L. Hammer
Hugo L. Hammer
Background In assisted reproductive technology, evaluating the quality of the embryo is crucial when selecting the most viable embryo for transferring to a woman. Assessment also plays an important role in determining the optimal transfer time, either in the cleavage stage or in the blastocyst stage. Several AI-based tools exist to automate the assessment process. However, none of the existing tools predicts upcoming video frames to assist embryologists in the early assessment of embryos. In this paper, we propose an AI system to forecast the dynamics of embryo morphology over a time period in the future. Methods The AI system is designed to analyze embryo development in the past two hours and predict the morphological changes of the embryo for the next two hours. It utilizes a predictive model incorporating Convolutional LSTM layers, to predict the future video frame by analyzing prior morphological changes within the embryo’s video sequence. The system uses the predictions recursively and forecasts up to 23 hours of embryo development. Results The results demonstrated that the AI system could accurately forecast embryo development at the cleavage stage on day 2 and the blastocyst stage on day 4. The system provided valuable information on the cell division processes on day 2 and the start of the blastocyst stage on day 4. The system focused on specific developmental features effective across both the categories of embryos. The embryos that were transferred to the female, and the embryos that were discarded. However, in the ‘transfer’ category, the forecast had a clearer cell membrane and less distortion as compared to the ‘avoid’ category. Conclusion This study assists in the embryo evaluation process by providing early insights into the quality of the embryo for both the transfer and avoid categories of videos. The embryologists recognize the ability of the forecast to depict the morphological changes of the embryo. Additionally, enhancement in image quality has the potential to make this approach relevant in clinical settings. Author summary The emergence of assisted reproductive technology has significantly improved infertility treatments. It involves fertilization of an egg outside the body, and the resultant embryos are developed in time-lapse incubators. The embryologists manually evaluate embryos using time-lapse videos and rank each embryo on the basis of several criteria including the dynamics of embryo cell stages, such as the start of the blastocyst stage. Traditional manual analysis is subjective and time-consuming, and AI tools are introduced to automate and enhance embryo selection efficiency. However, current AI tools do not generate video frames that forecast changes in embryo morphology. This study fills this gap by introducing an AI system that forecasts upcoming frames of a time-lapse video. In this approach, several hours were predicted ahead of the last video frame. The system was evaluated on crucial days of embryo evaluation. Our approach was effective in both good quality (transfer) and poor quality (avoid) video categories, and the forecast revealed crucial insights about embryo cell division and the start of the blastocyst stage. Despite some image quality issues, the proposed AI system demonstrated the potential for early and accurate assessment of embryo quality.

30 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ADAlexandru Dorobanțiu
Alexandru Dorobanțiu
Remus BradRemus Brad
Remus Brad
With the increased use of image acquisition devices, including cameras and medical imaging instruments, the amount of information ready for long term storage is also growing. In this paper we give a detailed description of the state-of-the-art lossless compression software PAQ8PX applied to grayscale image compression. We propose a new online learning algorithm for predicting the probability of bits from a stream. We then proceed to integrate the algorithm into PAQ8PX’s image model. To verify the improvements, we test the new software on three public benchmarks. Experimental results show better scores on all of the test sets.