Laser pulse amplification by a high-pressure CO2 amplifier in the long-wave infrared (LWIR) spectral range is a feasible technology for strong-field physics research. Crystals such as ZnGeP2 (ZGP) have high nonlinear coefficients and transmittance in the LWIR region, with spectral widths of generated pulses closely matching the gain spectrum of high-pressure CO2 amplifiers. Therefore, ZGP optical parametric oscillation (OPO) may allow higher-efficiency energy extraction in amplifiers, improving the output characteristics of LWIR amplification systems. In this study, the gain measurement of ZGP OPO pulses amplified by a high-pressure CO2 amplifier was carried out for the first time. Single-detector acquisition was utilized to achieve a unified sensor responsivity, and a laser signal-triggered function generator was used to synchronize the seed pulse and amplifier. Six-pass amplification was performed successively, yielding an amplification factor of 4.5 for the peak power and a maximum coefficient of 0.42% cm−1 for the small-signal gain. The gain and loss effect during small-signal amplification were discussed. The potential capability of acquiring ultra-short pulses with ZGP OPO pulses was also explored with the FFT function of MATLAB software.
Optical parametric oscillation (OPO) or optical parametric amplification (OPA) systems offer significant potential for generating high-energy, narrow-pulse laser output, finding applications across various domains. To achieve efficient amplification in cascade with amplifiers, precise frequency domain matching between OPO/OPA systems and amplifiers is imperative. Therefore, preliminary simulation and computation of the spectral characteristics of OPO/OPA systems are of paramount importance in the early stages of experimentation. Currently, the calculation of OPO/OPA output spectrum characteristics is limited to estimating the influence of pump light characteristics on output spectrum linewidth, a consideration that remains incomplete. This paper presents a comprehensive computational approach that takes into account the impact of four crucial factors on the output spectrum characteristics: pump light linewidth, pump light divergence angle, the walk-off effect, and the absorption loss of the crystal. This method finely characterizes the features of the output spectrum. The results obtained through the proposed approach align well with experimental results, underscoring its effectiveness. This study aims to obtain the output spectrum characteristics of BaGa4Se7 OPO/OPA through calculations to provide theoretical guidance for subsequent cascade amplification experiments.
This study systematically investigates the temporal characteristics of a high-pressure CO2 master oscillator power amplifier (MOPA) system under tunable spectral lines. Based on a continuously tunable CO2 oscillator–amplifier system, we experimentally measured the variation in the laser pulse width before and after amplification at different spectral lines, with the oscillator and amplifier operating at pressures of 7 atm and 3 atm, respectively. The results indicate that, for most spectral lines, the laser pulse width remained nearly unchanged after amplification. However, at certain spectral lines, a distinct phenomenon was observed: pulse broadening for strong lines and pulse narrowing for weak lines. To explain this phenomenon, theoretical calculations were conducted based on a high-pressure CO2 six-temperature model, and the experimental results were analyzed from the perspective of small-signal gain dynamics. This study reveals that variations in the laser pulse width primarily originated from differences in the gain build-up time across different spectral lines, which in turn influenced the amplification of both the pulse pedestal and the main pulse. For strong spectral lines, the amplifier gain built up rapidly, leading to more uniform amplification of the entire laser pulse and resulting in pulse broadening. Conversely, for weak spectral lines, the amplifier gain built up more slowly, with amplification primarily concentrated in the main pulse, causing a reduction in the pulse width. This finding has significant implications for optimizing narrow-pulse CO2 lasers and provides crucial insights into the temporal characteristics of applications, such as laser isotope separation and extreme ultraviolet (EUV) light source generation.