Steffen Weber

Mr. Steffen Weber


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MFMarc Fournelle
Marc Fournelle
TGTobias Grün
Tobias Grün
DSDaniel Speicher
Daniel Speicher
SWSteffen Weber
Steffen Weber
MYMehmet Yilmaz
Mehmet Yilmaz
HHHolger Hewener
Holger Hewener
We developed a new mobile ultrasound device for long-term and automated bladder monitoring without user interaction consisting of 32 transmit and receive electronics as well as a 32-element phased array 3 MHz transducer. The device architecture is based on data digitization and rapid transfer to a consumer electronics device (e.g., a tablet) for signal reconstruction (e.g., by means of plane wave compounding algorithms) and further image processing. All reconstruction algorithms are implemented in the GPU, allowing real-time reconstruction and imaging. The system and the beamforming algorithms were evaluated with respect to the imaging performance on standard sonographical phantoms (CIRS multipurpose ultrasound phantom) by analyzing the resolution, the SNR and the CNR. Furthermore, ML-based segmentation algorithms were developed and assessed with respect to their ability to reliably segment human bladders with different filling levels. A corresponding CNN was trained with 253 B-mode data sets and 20 B-mode images were evaluated. The quantitative and qualitative results of the bladder segmentation are presented and compared to the ground truth obtained by manual segmentation.

22 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CRChristoph Risser
Christoph Risser
HHHolger Hewener
Holger Hewener
MFMarc Fournelle
Marc Fournelle
HFHeinrich Fonfara
Heinrich Fonfara
SBSelina Barry-Hummel
Selina Barry-Hummel
STSteffen Tretbar
Steffen Tretbar
Volumetric ultrasound imaging is of great importance in many medical fields, especially in cardiology, but also in therapy monitoring applications. For development of new imaging technologies and scanning strategies, it is crucial to be able to use a hardware platform that is as free and flexible as possible and does not restrict the user in his research in any way. For this purpose, multi-channel ultrasound systems are particularly suitable, as they are able to control each individual element of a matrix array without the use of a multiplexer. We set out to develop a fully integrated, compact 1024-channel ultrasound system that provides full access to all transmission parameters and all digitized raw data of each transducer element. For this purpose, we synchronize four research scanners of our latest “DiPhAS” ultrasound research system generation, each with 256 parallel channels, all connected to a single PC on whose GPUs the entire signal processing is performed. All components of the system are housed in a compact, movable 19-inch rack. The system is designed as a general-purpose platform for research in volumetric imaging; however, the first-use case will be therapy monitoring by tracking radiation-sensitive ultrasound contrast agents.

25 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DSDaniel Speicher
Daniel Speicher
TGTobias Grün
Tobias Grün
SWSteffen Weber
Steffen Weber
HHHolger Hewener
Holger Hewener
SKStephan Klesy
Stephan Klesy
MFMarc Fournelle
Marc Fournelle
Reliable acoustic coupling in a non-handheld mode and reducing the form factor of electronics are specific challenges in making ultrasound wearable. Applications relying on a large field of view (such as tracking of large muscles) induce a need for a large element count to achieve high image quality. In our work, we developed a 256-element linear array for imaging of abdominal muscles with four integrated custom-developed 8:32 multiplexer Integrated Circuits (ICs), allowing the array to be driven by our compact 32 ch electronics. The system is optimized for flexible use in R&D applications and allows adjustable transmit voltages (up to +/−100 V), arbitrary delay patterns, and 12-bit analog-to-digital conversion (ADC) with up to 50 MSPS and wireless (21.6 MBit/s) or USB link. Image metrics (SLL, FWHM) were very similar to a fully populated array driven with a 256 ch system. The contrast allowed imaging of lesions down to 7 cm in the phantom. In a first in-vivo study, we demonstrated reliable acoustic contact even during exercise and were able to visualize deep abdominal muscles such as the TrA. In combination with a muscle tracking algorithm, the change of thickness of the TrA during SSE could be monitored, demonstrating the potential of the approach as biofeedback for physiotherapy training.

1 January 2017 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
WBWolfgang Bost
Wolfgang Bost
MOMilan Oeri
Milan Oeri
SWSteffen Weber
Steffen Weber
STSteffen Tretbar
Steffen Tretbar
MFMarc Fournelle
Marc Fournelle