To enhance the adaptability of grid partitioning under transient scenarios, this paper proposes a two-stage dynamic partitioning strategy based on structure–function coupling. Electrical coupling strength is first characterized using short-circuit impedance and the sensitivity between reactive power and voltage, while transient voltage correlation is incorporated through cosine similarity as edge weights in a graph model. Grid partitioning is then conducted by maximizing modularity through a staged approach that ensures network connectivity and automatically determines partition numbers. Case studies on the modified IEEE 39-bus system demonstrate that compared with transient voltage-based partitioning and conventional complex network methods, the proposed approach improves modularity by 69%, reduces the maximum post-fault voltage deviation by 38.6%, and achieves the highest regional decoupling rate. The result shows strong intra-regional cohesion and weak inter-regional connectivity, verifying the strategy’s effectiveness in enhancing adaptability and decoupling under transient conditions.
The high rate of photovoltaic integration poses significant challenges in terms of violations of voltage limits in power grids. Additionally, the operational behavior of PV systems under fault conditions requires thorough investigation in receiving-end grids. This paper analyzes the dynamic coupling characteristics between reactive power and transient voltage in a receiving-end grid with high PV penetration and multiple HVDC infeeds, considering typical AC and DC fault scenarios. Voltage adaptability issues in PV generation systems are also examined. Through an enhanced sensitivity analysis method, the suppression capabilities of transient voltage peaks are quantified in the control parameters of low-voltage ride-through (LVRT) and high-voltage ride-through (HVRT) photovoltaic inverters. On this basis, a hierarchical optimization strategy for PV inverter control parameters is proposed to mitigate post-fault transient voltage peaks and improve the transient voltage response both during and after faults. The feasibility of the proposed method has been verified through simulation on a revised 10-generator 39-bus power system. Following optimization, the transient voltage peak is reduced from 1.263 to 1.098. This validation offers support for the reliable grid connection of the Henan Power Grid. In the events of the N-2 fault at 500 kV and Tian-zhong HVDC monopolar block fault, the post-fault voltage at each node remains below 1.1 p.u. This serves as evidence of a significant enhancement in transient voltage stability within the Henan Power Grid, demonstrating effective improvements in power supply reliability and operational performance.
The increasing randomness and volatility of renewable energy resources have raised higher demands for circuit breakers. Utilizing monitoring data enables more accurate condition assessment; however, the imbalance between fault and normal samples hampers the performance of machine-learning-based assessment. To address the overfitting and limited diversity of traditional oversampling methods, this paper proposes a Transformer-conditioned CWGAN-GP (TCWGAN-GP) model to generate multi-class fault samples for data augmentation. The generator of the proposed model takes random noise and class labels as input to capture the distribution characteristics of real fault samples. By combining a transformer-based generator to model inter-feature dependencies among 14 monitoring indicators and a WGAN-GP training objective with gradient penalty, the proposed approach improves training stability and synthetic sample quality. Moreover, a three-stage state assessment method based on XGBoost is developed to sequentially assess health status, fault category, and fault severity. Results demonstrate that the proposed method in the paper outperforms conventional data augmentation methods and single-stage classifiers in terms of accuracy, recall, F1-score, and online prediction efficiency. Specifically, the proposed three-stage model achieves an overall assessment accuracy of 93.10%, outperforming the single-stage XGBoost framework. In terms of online efficiency, the initial anomaly detection stage requires only 0.0041 s per sample, which is a substantial reduction compared to the 0.0241 s required by the single-stage model. Furthermore, compared to traditional Random Oversampling (ROS) and SMOTE, the TCWGAN-GP augmentation yields superior evaluation performance on fully balanced datasets, achieving a recall rate of 91.26% and an F1-score of 92.61%. Overall, the proposed TCWGAN-GP and three-stage XGBoost method contributes to addressing data imbalance challenges and improving the accuracy of circuit breaker state assessment.