LIXIA SUN

Dr. LIXIA SUN

HOHAI UNIVERSITY

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
XLXue Lin
Xue Lin
LIXIA SUNLIXIA SUN
LIXIA SUN
Ping JUPing JU
Ping JU
HLHongyu Li
Hongyu Li
With the penetration of renewable generation, electric vehicles and other random factors in power systems, the stochastic disturbances are increasing significantly, which are necessary to be handled for guarantying the security of systems. A novel stochastic optimal control strategy is proposed in this paper to reduce the impact of such stochastic continuous disturbances on power systems. The proposed method is effective in solving the problems caused by the stochastic continuous disturbances and has two significant advantages. First, a simplified and effective solution is proposed to analyze the system influenced by the stochastic disturbances. Second, a novel optimal control strategy is proposed in this paper to effectively reduce the impact of stochastic continuous disturbances. To be specific, a novel excitation controlled power systems model with stochastic disturbances is built in the quasi-generalized Hamiltonian form, which is further simplified into a lower-dimension model through the stochastic averaging method. Based on this Itô equation, a novel optimal control strategy to achieve the intra-region probability maximization is established for power systems by using the dynamic programming method. Finally, the intra-region probability increases in controlled systems, which confirms the effectiveness of the proposed control strategy. The proposed control method has advantages on controlling the fluctuation of system state variables within a desired region under the influence of stochastic disturbances, which means improving the security of stochastic systems. With more stochasticity in the future, the proposed control method based on the stochastic theory will play a novel way to relieve the impact of stochastic disturbances.

14 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
LIXIA SUNLIXIA SUN
LIXIA SUN
XSxian xue Sha
xian xue Sha
SZShuo Zhang
Shuo Zhang
JWJiaHao Wang
JiaHao Wang
YYYiping Yu
Yiping Yu
To enhance the adaptability of grid partitioning under transient scenarios, this paper proposes a two-stage dynamic partitioning strategy based on structure–function coupling. Electrical coupling strength is first characterized using short-circuit impedance and the sensitivity between reactive power and voltage, while transient voltage correlation is incorporated through cosine similarity as edge weights in a graph model. Grid partitioning is then conducted by maximizing modularity through a staged approach that ensures network connectivity and automatically determines partition numbers. Case studies on the modified IEEE 39-bus system demonstrate that compared with transient voltage-based partitioning and conventional complex network methods, the proposed approach improves modularity by 69%, reduces the maximum post-fault voltage deviation by 38.6%, and achieves the highest regional decoupling rate. The result shows strong intra-regional cohesion and weak inter-regional connectivity, verifying the strategy’s effectiveness in enhancing adaptability and decoupling under transient conditions.

19 January 2026 in Processes
Verified
Journal Article
Open access
PDF file
RSRan Sun
Ran Sun
JWJianbo Wang
Jianbo Wang
FYFeng Yao
Feng Yao
ZCZhaohui Cui
Zhaohui Cui
XLXiaomeng Li
Xiaomeng Li
LIXIA SUNLIXIA SUN
LIXIA SUN
The high rate of photovoltaic integration poses significant challenges in terms of violations of voltage limits in power grids. Additionally, the operational behavior of PV systems under fault conditions requires thorough investigation in receiving-end grids. This paper analyzes the dynamic coupling characteristics between reactive power and transient voltage in a receiving-end grid with high PV penetration and multiple HVDC infeeds, considering typical AC and DC fault scenarios. Voltage adaptability issues in PV generation systems are also examined. Through an enhanced sensitivity analysis method, the suppression capabilities of transient voltage peaks are quantified in the control parameters of low-voltage ride-through (LVRT) and high-voltage ride-through (HVRT) photovoltaic inverters. On this basis, a hierarchical optimization strategy for PV inverter control parameters is proposed to mitigate post-fault transient voltage peaks and improve the transient voltage response both during and after faults. The feasibility of the proposed method has been verified through simulation on a revised 10-generator 39-bus power system. Following optimization, the transient voltage peak is reduced from 1.263 to 1.098. This validation offers support for the reliable grid connection of the Henan Power Grid. In the events of the N-2 fault at 500 kV and Tian-zhong HVDC monopolar block fault, the post-fault voltage at each node remains below 1.1 p.u. This serves as evidence of a significant enhancement in transient voltage stability within the Henan Power Grid, demonstrating effective improvements in power supply reliability and operational performance.

5 November 2024 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
SZShi Zhang
Shi Zhang
SRShao Yi Ren
Shao Yi Ren
BZBo Zhang
Bo Zhang
JFJiang Zhe Feng
Jiang Zhe Feng
XZXin Gang Zhang
Xin Gang Zhang
LIXIA SUNLIXIA SUN
LIXIA SUN
With the increasing integration of renewable energy sources and the presence of numerous controllable loads such as electric vehicles and energy storage in the modern power system, higher nonlinearities and uncertainty both sources and loads are introduced. These factors pose challenges in achieving fast and accurate emergency frequency control. Therefore, this paper addresses the issue of dual source-load uncertainties in power system and presents an optimization strategy based on the Soft Actor Critic (SAC) algorithm that involves the participation of controllable loads in emergency frequency control. Firstly, the spatio-temporal uncertainties of wind farm power output on power supply side and power demand on the load side are described using Weibull and normal probability distributions, respectively. Secondly, an improved Markov Decision Process (MDP) model for emergency frequency control is established, which considers the characteristics of the dual source-load uncertainties. Finally, an optimization of the SAC algorithm is conducted based on Deep Reinforcement Learning (DRL), aiming to achieve rapid system frequency recovery and minimize the cost of removing controllable loads. The presented approach in the paper enhances the emergency frequency control strategy for uncertain power systems and effectively addresses the issue of source-load uncertainty compounded by fault power shortages.

14 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
LIXIA SUNLIXIA SUN
LIXIA SUN
LWLing Wang
Ling Wang
JWJiaHao Wang
JiaHao Wang
ZLZijia Liu
Zijia Liu
The increasing randomness and volatility of renewable energy resources have raised higher demands for circuit breakers. Utilizing monitoring data enables more accurate condition assessment; however, the imbalance between fault and normal samples hampers the performance of machine-learning-based assessment. To address the overfitting and limited diversity of traditional oversampling methods, this paper proposes a Transformer-conditioned CWGAN-GP (TCWGAN-GP) model to generate multi-class fault samples for data augmentation. The generator of the proposed model takes random noise and class labels as input to capture the distribution characteristics of real fault samples. By combining a transformer-based generator to model inter-feature dependencies among 14 monitoring indicators and a WGAN-GP training objective with gradient penalty, the proposed approach improves training stability and synthetic sample quality. Moreover, a three-stage state assessment method based on XGBoost is developed to sequentially assess health status, fault category, and fault severity. Results demonstrate that the proposed method in the paper outperforms conventional data augmentation methods and single-stage classifiers in terms of accuracy, recall, F1-score, and online prediction efficiency. Specifically, the proposed three-stage model achieves an overall assessment accuracy of 93.10%, outperforming the single-stage XGBoost framework. In terms of online efficiency, the initial anomaly detection stage requires only 0.0041 s per sample, which is a substantial reduction compared to the 0.0241 s required by the single-stage model. Furthermore, compared to traditional Random Oversampling (ROS) and SMOTE, the TCWGAN-GP augmentation yields superior evaluation performance on fully balanced datasets, achieving a recall rate of 91.26% and an F1-score of 92.61%. Overall, the proposed TCWGAN-GP and three-stage XGBoost method contributes to addressing data imbalance challenges and improving the accuracy of circuit breaker state assessment.